MAURY USCG vessel records
← All vessels

MARIA H

MARIA H is a 2003 freight ship. The Coast Guard has recorded 24 inspections since 2016, most recently in December 2024, along with 24 deficiencies and 3 operational controls.

Records from 2016 to 2024. Most recent: inspection, 1 December 2024.

Built
2003
Last inspected
1 December 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 1 December 2024
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9247754
620247
Flag
CYPRUS
Maury page id
psix-620247

Documentation record

Tonnage as PSIX records it108184 - Displacement, Metric Ton
81171 - Dead Weight, Metric Ton
75484 - Convention (Subpart B), Gross Ton
29555 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

24 inspections, each with its date, unit and type; 24 deficiencies with the resolution recorded against each; 3 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 24

1 December 2024 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8041558
25 November 2024 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8037813
20 November 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8037809
11 May 2024 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7910639
4 May 2024 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7906505
2 March 2023 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7643930
19 September 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7562038
3 September 2022 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7549985
1 March 2022 PSC A
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7403688
11 August 2021 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7283467
10 August 2021 PSC A
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7282738
15 June 2021 PSC A
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7225680
9 June 2021 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7220589
8 June 2021 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7219286
4 June 2021 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7215334
1 April 2021 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7167030
19 January 2021 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7126655
12 November 2020 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 7094180
9 November 2020 PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7092140
7 November 2020 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7091345
8 May 2018 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6408984
4 April 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6117434
24 January 2017 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6076101
19 December 2016 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6060029

Deficiency record · 24

10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 11 May 2024 Resolved
All ships 300 GT and upwards shall be fitted with a 9 GHz radar, or other means, to determine and display the range and bearing of radar transponders and of other surface craft, obstructions, buoys, shoreline and navigational marks to assist in navigation and in collection avoidance. Vessel has malfunctioning 9 GHz radar.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 May 2024
Resolution: Recieved tech report attesting to repairs.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 11 May 2024 Resolved
All ships of 3,000 Gt and upwards shall have a 3 GHz radaror, where considered appropriate by the Administration, a second 9 GHz radar, or other means, to determine and display the range and bearing of other surface craft, obstructions, buoys, shorelines and navigational marks to assist in navigation and in collision avoidance, which are functionally independent of those referred to in paragraph 2.3.2. Vessel has malfunctioning 3 GHz radar. Vessel is required to repair and provide technician report attesting to the repairs to the Coast Guard.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 May 2024
Resolution: Recieved tech report attesting to repairs
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 May 2024 Resolved
THE PURPOSE OF THIS REGULATION IS TO PREVENT THE IGNITION OF COMUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS. FOR THIS PURPOSE THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: IGNITION SOURCES SHALL BE RESTRICTED. PSCO OBSERVED EMERGENCY LIGHT IN FUEL PURIFIER SPACE TO HAVE WIRES EXPOSED AND AN OPEN JUNCTION. 74SOLAS(04)ii-2/4.1.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 May 2024
Resolved 7 May 2024
Resolution: Received report from RO attesting to the repair of the system.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 May 2024 Resolved
A MAIN ELECTRIC LIGHTING SYSTEM WHICH SHALL PROVIDE ILLUMINATION THROUGHOUT THOSE PARTS OF THE SHIP NORMALLY ACCESSIBLE... SHALL BE SUPPLIED FROM THE MAIN SOURCE OF ELECTRICAL POWER. PSCO OBSERVED OVER 30 ENGINE ROOM LIGHTS EXTINGUISHED OR MISSING. 74SOLAS(04)II-1/41.2.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 May 2024
Resolved 7 May 2024
Resolution: Received report from RO attesting to the repair of the system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 June 2021 Resolved
THE UTILIZATION OF OIL USED IN PRESSURE LUBRICATION SYSTEMS SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ON BOARD. PSCO OBSERVED EXCESSIVE LEAKS ON EMERGENCY GENERATOR. SOLAS (01 CONS) II-2/ 15.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 June 2021
Resolution: Received class report attesting to an inspection performed on the Emergency Generator. Found in good working condition. Vessel released from restriction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 June 2021 Resolved
OIL FUEL LINES SHALL BE SCREENED OR OTHERWISE SUITABLY PROTECTED TO AVOID, AS FAR AS PRACTICABLE, OIL SPRAY OR OIL LEAKAGES ONTO HOT SURFACES. PSCO OBSERVED HIGH PRESSURE FUEL LINE PROTECTION DAMAGED AND NOT CONTINUOUS ON NUMBER TWO GENERATOR, CYLINDER EIGHT. SOLAS (04 CONS) II-2/ 15.2.11
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2021
Resolved 11 August 2021
Resolution: Recieved class report.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 June 2021 Resolved
THE MACHINERY, BOILERS AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE SO INSTALLED AND PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD. PSCO OBSERVED FUMES COMING FROM TANK VENT ASSOCIATED WITH AUXILIARY ENGINE EXHAUST SCRUBBER IN THE VICINITY OF A WALKWAY, POSING A HAZARD TO THE CREW. SOLAS (04 CONS) II-1/ 26.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2021
Resolved 11 August 2021
Resolution: Recieved class report.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 15 June 2021 Resolved
THE COMPANY SHOULD ESTABLISH PROCEDURES TO ENSURE THAT THE SHIP IS MAINTAINED. IN MEETING THESE REQUIREMENTS, THE COMPANY SHOULD ENSURE THAT INSPECTIONS ARE HELD AT APPROPRIATE INTERVALS. SHIPS CREW COULD NOT PROVIDE PROPER PROCEDURES FOR MAINTINANCE AND OPERATION OF THE EMERGENCY GENERATOR. SOLAS (20 CONS) IX/3.1 ISM 10
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2021
Resolved 11 August 2021
Resolution: Recieved class report.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 June 2021 Resolved
07126 - In a ship which oil fuel is used the arrangements for the storage, distribution, and utilization of the fuel shall be as such as to ensure the safety of the ship and persons onboard. PSCO's observed numerous oil leaks on the main engine, with oil soaked rags in various spaces and around piping. PSCO observed leaks from all 4 generators. The main fuel oil transfer pump was leaking fuel oil and had a bucket filled with fuel oil beneath it. There was also a bucket of oil on the second deck of the main engine. A HFO line on the HFO settling tank was leaking on the same tank there was a flange actively leaking fuel oil with oil pooled beneath it with a bucket collecting oil. 74SOLAS(01), II-2/15.2
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 12 June 2021
Resolution: RINA Surveyor provided class report, attesting to rectification of oil leaks and cleaning of oil in engine room.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 8 June 2021 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. The class report for a previous U.S. Coast Guard Port State Control exam required the vessel to monitor and identify leaks on the main engine, diesel generators, and purifiers. PSCO requested documentation showing the leaks were being identified and monitored for rectification and the vessel was unable to provide correspondence or dicumentation. The vessel did provide direction from the company stating excessive oil leaks must always be cleaned and oil soaked rags were not to be left on the main engine or diesel generators which was contradictory to PSCO's observations. Due to the objective evidence in the above deficiencies, the vessel is not in substantial compliance with relevant conventions. The Captain of the Port questions the adequacy and overall implementation of the vessel's SMS under the ISM Code. An external audit conducted by the Flag or RO is required to determine whether the ship is operating in accordance with the ISM Code. Provide a copy of the completed audit report to USCG prior to departure from port. 74SOLAS(14)IX/3.1 ISM Code 10.1
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 12 June 2021
Resolution: Rina attended vessel and found one non-conformity. See attached class reports.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 8 June 2021 Resolved
MARPOL, ANNEX I 14.6 & MEPC 107(49) 1.2.4: Fuel oil content meters, tests should be performed using three grades of test fluids. PSCO observed crew testing 15 ppm bilge seperator with coffee.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 8 June 2021
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 4 June 2021 Resolved
In a ship in which fuel oil is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. PSCO observed excessive leaking on all four auxiliary diesel engines. 74SOLAS(01) II/2 15.2 MSC/Circ.647
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 4 June 2021
Resolved 6 June 2021
Resolution: Received class report attesting to repair.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 4 June 2021 Resolved
In a ship in which fuel oil is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board and shall at least comply with the following provisions; precautions shall be taken to prevent any oil that may escape under pressure from any pump, filter, or heater from coming into contact with heated surfaces. PSCO observed leaking fuel oil and the resulting oil soaked lagging on the number four purifier. 74SOLAS(01) II/2 15.2 MSC/Circ.647
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 4 June 2021
Resolved 6 June 2021
Resolution: Received class report attesting to repair.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 4 June 2021 Resolved
The company should establish procedures to ensure the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. There is no evidence that the vessel’s crew was taking appropriate action to prevent fire potential in the engine room nor taking steps to ensure integral systems on board the vessel are properly maintained. Recommend ISM audit. 74SOLAS(20) IX/3.1 ISM Code 10.1
Condition: Placed in Improper Service
Action required: 30 - Ship detained
Due 4 June 2021
Resolved 6 June 2021
Resolution: Received class report attesting to repair.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 4 June 2021 Resolved
Any ship of 10,000 gross tonnage and above shall be fitted with oil filtering equipment. PSCO witnessed inoperable OWS, three-way valve solenoid valve was inoperable. MARPOL I/14.2
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 4 June 2021
Resolved 6 June 2021
Resolution: Received class report attesting to repair.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Incinerator incl. operations and operating manual
Issued 4 June 2021 Resolved
Shipboard incineration of polyvinyl chlorides (PVC) shall be prohibited, except in shipboard incinerators for which the IMO Type Approval Certificates have been issued. PSCO observed plastics being burnt in the incinerator without the proper type approval. MARPOL VI/16.3
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 4 June 2021
Resolved 6 June 2021
Resolution: Received class report attesting to repair.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 4 June 2021 Resolved
All surfaces with temperatures above 220°C which may be impinged as a result of a fuel system failure shall be properly insulated. PSCO observed wasted lagging on the #4 generator. 74SOLAS(01) II-2/15.2.10
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 June 2021
Resolved 6 June 2021
Resolution: Received class report attesting to repair.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 4 June 2021 Resolved
In a ship in which oil fuel is used, the arrangements for the storage, distribution and utilization of the oil fuel shall be such as to ensure the safety of the ship and persons on board. PSCO observed excessive leaking on the main diesel engine, and multiple unapproved oil collection methods. 74SOLAS(01) II-2/15.2 MSC/Circ.647
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 4 June 2021
Resolved 6 June 2021
Resolution: Received class report attesting to repair.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 June 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed multiple hoses actively leaking an oil/water mixture into the clean drain tank. 74 SOLAS (20) I/11(a)
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 4 June 2021
Resolved 6 June 2021
Resolution: Received class report attesting to repair.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 4 June 2021 Resolved
Each operation shall be fully recorded without delay in the oil record book, so that all entries in the book appropriate to that operation are completed. PSCO observed multiple ORB errors, missing sludge transfers, codes and dates. 17Mar2021 missing date and code. MARPOL 1/17.4
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2021
Resolved 6 June 2021
Resolution: Received class report attesting to repair.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 June 2021 Resolved
The machinery, boilers and other pressure vessels, associated piping and fittings shall be of a design and construction adequate for the service which they are intended. PSCO observed modification to the ballast line in engine room. 74SOLAS(04) II-1 /26.1
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2021
Resolved 6 June 2021
Resolution: Received class report attesting to repair.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 June 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Leak observed on exhaust gas scrubber line in engine room. 74SOLAS(20) I/11(a)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2021
Resolved 6 June 2021
Resolution: Received class report attesting to repair.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 June 2021 Resolved
Any required fixed fire detection shall be capable of immediate operation at all times. PSCO observed a covered smoke alarm above #4 Generator. 74 SOLAS (01) II-2/13.1.1
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 4 June 2021
Resolved 4 June 2021
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 4 June 2021 Resolved
Fire extinguishing appliances shall be kept in good order and be available for immediate use at all times. Observed buckets over sprinkler heads in pain locker. 74SOLAS(01) II-2/21
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 4 June 2021
Resolved 4 June 2021

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.