LINDA

LINDA is a 2003 tank ship. The Coast Guard has recorded 19 inspections since 2016, most recently in February 2020, along with 6 deficiencies and 2 operational controls.

Records from 2016 to 2020. Most recent: inspection, 17 February 2020.

Built
2003
Last inspected
17 February 2020
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 February 2020
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9256858
620353
Flag
LIBERIA
Maury page id
psix-620353

Documentation record

Tonnage as PSIX records it133065 - Displacement, Metric Ton
115418 - Dead Weight, Metric Ton
61991 - Convention (Subpart B), Gross Ton
34668 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 19

17 February 2020 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6910172
29 November 2019 COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6864520
24 November 2019 In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6861400
23 November 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6864591
4 November 2019 ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6842947
1 November 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6846813
1 November 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6846878
1 November 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6857471
28 October 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6843742
17 April 2017 COE-Administrative · COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6123627
9 February 2017 COE-Administrative
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6080617
18 January 2017 COE-Dockside
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6065164
20 December 2016 COE-Administrative
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6057747
30 November 2016 COE-Administrative
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6044608
5 November 2016 COE-Dockside
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6032378
16 July 2016 COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5942546
15 July 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5941748
22 March 2016 COE-Administrative
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5835095
10 January 2016 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5794537

Deficiency record · 6

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 February 2020 Resolved
Not less than half of the lifebouys shall be provided with lifebouy self igniting lights complying with the requirements of paragraph 2.1.2 of the code. The lights on all of the bouys were not configured to be seflf igniting
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 17 February 2020
Resolution: ships crew installed proper appliances for self ignition on all appropriate lifebouys
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 November 2019 Resolved
Where remote control of propulsion machinery from teh navigation bridge is provided and the machinery spaces are intended to be manned, the following shall apply: automation systems shall be designed in a manner which ensures that threshold warning of impending or imminent slowdown or shutdown of the propulsion system is given to the officer in charge of the navigational watch in time to assess navigational circumstances in an emergency. In particular, the systems shall control, monitor, report, alert and take safety action to slow down or stop propulsion while providing the officer in charge of the navigational watch an opportunity to manually intervene, except for those cases where manual intervention will result in total failure of the engine and/or propulsion equipment within a short time for example in the case of overspeed. PSCO reviewed alarm history for the MDE and found that the #1 cylinder had a high temperature alarm warning at 437 deg celsius, 454 deg celsius and slow down activation simutanesously; which resulted in a slow down immediately wihtout a chance from the navigation officer to override the alarm during a passing arrangement while pilot was on board. Ships crew could not provide full ahead for a significant amount as requested by the pilot. 74 SOLAS (a) 2014 Con II-1/31.2.10
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 24 November 2019
Resolved 28 November 2019
Resolution: Received class report from ABS stating engine was functioning properly and a new thermocoupler was replaced,
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 November 2019 Resolved
07199-Other (fire safety)-The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose the following functional requirements shall be met: 1. means shall be provided to control leaks of flammable liquids. PSCO observed fuel oil leaks on #3 cylinder MDE high pressure fuel pump, and #2 and #3 fuel injectors on MDE. SOLAS 74 (2014) II-2/4.1 60a/c
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 24 November 2019
Resolved 28 November 2019
Resolution: Received class report from ABS that fuel inectors and high pressure fuel pump was corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 November 2019 Resolved
13101-Propulsion main engine-Means shall be provided whereby normal operation of propulsion machinery can be sustained or restored even though one of the essential auiliaries becomes inoperative. Special consideration shall be given to the malfunctioning of the hydraulic, pneumatic or electrical means for control in main propulsion machinery including controllable pitch propellors. PSCO observed control air dryer bypassed and not in operation. No mention of dryer in starting procedures for MDE. Chief Engineer stated it should be in operation and not bypassed. SOLAS 74 (2014) II-1/26.3.10 60a/c
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Due 24 November 2019
Resolved 28 November 2019
Resolution: Received class report from ABS attesting to the proper operation of the Air dryer.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 November 2019 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. The design shall have regard to materials used in construction, the purpose for which the equipment is intended, the working conditions to which it will be subjected and the environmental conditions on board. PSCO observed a main diesel engine jacket water cooling system was actively leaking from cylinders #3 and #6. SOLAS 74 (2014) II-1/26.1 60a/c
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 24 November 2019
Resolved 28 November 2019
Resolution: Received class report from ABS attesting to the condition of the jacket water cooling stating it was due to river temperature.
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 4 November 2019 Resolved
Steering gear control shall be provided: Where the main steering gear is arranged in accordance with paragraph 6. By two independent control systems, both operable from the navigation bridge. This does not require duplication of the steering wheel or steering lever. Where the control system consists of a hydraulic telemotor, a second independent system need not be fitted, except in a tanker, chemical tanker, or gas carrier of 10,000 gross tonnage and upwards. While conducting Steering test from helm station on bridge. PSCO identified that while operating in hand mode on No.2 system, the steering only operates to the maximum of 30 degrees to PORT and 32 degrees to STBD. All other systems were tested Sat.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 November 2019
Resolution: Received class report from ABS clearing this deficiency. Rudder fixed.