MAURY USCG vessel records Sign in
← All vessels

SMJ-1

SMJ-1 is a 2003 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2003, most recently in March 2017, along with 24 deficiencies.

Records from 2003 to 2017. Most recent: inspection, 17 March 2017.

Built
2003
Last inspected
17 March 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

----------
620648
Flag
UNITED STATES
—
Maury page id
psix-620648

Inspections, by type

Years with a record 9 calendar years (2003–2017)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it0 - Simplified, Gross Ton
0 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 17

17 March 2017 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6106806
29 October 2014 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5014127
11 August 2014 Examination of Repairs
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4947277
25 June 2014 Examination of Repairs · Annual Inspection · Simplified Stability Test
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 4888002
29 March 2010 COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3704950
7 July 2008 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3261820
31 January 2008 Simplified Stability Test · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3167803
5 April 2007 Annual Inspection
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2904210
7 April 2006 Annual Inspection
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2696031
1 August 2005 Administrative Inspection
Administrative · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2447445
15 April 2005 Deficiency Check · Simplified Stability Test
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2338662
18 March 2005 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2289223
25 August 2004 Administrative Inspection
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2176124
12 May 2004 Re-Inspection · Simplified Stability Test
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2004844
27 June 2003 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1828316
11 June 2003 Administrative Inspection
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1814743
15 May 2003 Initial Certification · Hull Examination · Plan Review "T" Boat
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1791864

Deficiency record · 24

Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 25 June 2014 Resolved
Attending inspector noted that pre-engineered fire suppression system does not shut engine off when activated (tested). Ventilation does shut-down but engine does not.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 July 2014
Resolved 24 September 2014
Resolution: corrected
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 25 June 2014 Resolved
Attending inspectors called out missing hose clamps IWO exhaust flexible hoses at transom (external).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 July 2014
Resolved 26 June 2014
Resolution: Attending inspectors witnessed installation of four hose clamps IWO flexible hose for exhaust.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 25 June 2014 Resolved
Attending inspector noted inoperable RPM gauge while conducting u/w test of vessel systems.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 July 2014
Resolved 24 September 2014
Construction/Loadline › Hull › Bottom Plating
Issued 25 June 2014 Resolved
Attending inspector called out improper repair to hull plating IWO port side @ bow. Insert measured 10" x 3 1/2".
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 25 July 2014
Resolved 25 June 2014
Resolution: Attending inspector verified new hull insert (18" x 18") and tested IAW ABS Rules for NDT.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 25 June 2014 Resolved
Attending inspectors called out loose/missing hardware IWO main seating & deck plating (passenger accomodations/seating)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2014
Resolved 24 September 2014
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 25 June 2014 Resolved
Attending inspector called out portable B-II fire extinguisher IWO 2nd row seating (annual servicing).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2014
Resolved 25 June 2014
Resolution: Attending inspector witnessed installation of new B-II extinguisher that was within service intervals.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 25 June 2014 Resolved
Attending inspector called out engine hatch cover not being gasketed to prevent escape of fixed gas (pre-engineered fire suppression system, i.e.: Fireboy).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 July 2014
Resolved 24 September 2014
Resolution: gasket material added to the engine area cover.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 25 June 2014 Resolved
Attending inspector called out missing vapor barrier IWO machinery space, port & starboard (located between passenger seating insert & side shell). These areas are not vapor tight and may allow explosive vapors to travel fwd to console.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 July 2014
Resolved 24 September 2014
Engineering › Bilge Water Management System › Piping
Issued 25 June 2014 Resolved
Attending inspector called out loose clamps IWO bilge discharge hose @ hull penetration.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2014
Resolved 25 June 2014
Resolution: Attending inspector verified tightening of loose clamp IWO bilge discharge hose @ hull penetration.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 25 June 2014 Resolved
Attending inspector noted open holes IWO 4th row seating (non vapor tight) that would allow the escape of fixed firefighting gas (Fireboy).
Action required: 705 - Other - as specified
Due 25 July 2014
Resolved 25 July 2014
Resolution: Redundant discrepancy item.
Fire Fighting › Ventilation Systems › Ducts
Issued 25 June 2014 Resolved
Attending inspector noted exhaust blower duct for machinery space was holed, required replacment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2014
Resolved 25 June 2014
Resolution: Attending inspector witnessed renewal of exhaust ducting.
Engineering › Fuel Oil Service System › Hose
Issued 25 June 2014 Resolved
Attending inspector noted securing clamp IWO port fuel tank vent hose was loose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2014
Resolved 25 June 2014
Resolution: Attending inspector witnessed the tightening of the clamps IWO port fuel tank vent hose.
Fire Fighting › Ventilation Systems › Ducts
Issued 25 June 2014 Resolved
Attending inspector noted vessel is not equipped with ventilation closure devices (intake/exhaust).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 July 2014
Resolved 24 September 2014
Documentation › Logs/Records › Logbook (official)
Issued 25 June 2014 Resolved
Attending inspector noted that vessel does not log training/drills. Vessel owner/operator to provide required logs/records to attending inspector(s).
Action required: 705 - Other - as specified
Due 25 July 2014
Resolved 24 September 2014
Resolution: electronic log added to vessel daily operations.
Construction/Loadline › Hull › Weld
Issued 25 June 2014 Resolved
Attending inspector called out fractured weldment IWO port side ride plate assembly (beneath swim platform, port side).
Action required: 705 - Other - as specified
Due 25 July 2014
Resolved 14 August 2014
Resolution: Attending inspectors verified repairs made IWO port side ride plate assembly (re-welded).
Construction/Loadline › Structures › Transverse Bulkhead
Issued 25 June 2014 Resolved
Attending inspector called out holes IWO rear seat backs (4th row seating @ machinery space). Space is protected by pre-engineered fire suppression system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2014
Resolved 24 September 2014
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 7 July 2008 Resolved
Incorrect water light installed on ring buoy, remove light and install a floating water light meeting USCG approval 161.010. No night time operations until proper light is installed.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 August 2008
Resolved 3 September 2009
Resolution: Corrected.
Engineering › Fuel Oil Service System › Hose
Issued 7 July 2008 Resolved
Repair/replace leaking fuel line to port fuel filter, Corrected on the spot.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 July 2008
Resolved 7 July 2008
Personnel › Training › First Aid/CPR
Issued 7 July 2008 Resolved
Provide proof of 50% crew with first aid training.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 August 2008
Resolved 3 September 2009
Resolution: Provided.
Lifesaving › Hand Flares › Expired
Issued 18 March 2005 Resolved
PROVIDE PROPER TYPE AND QUATITY OF FLARES.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2005
Resolved 15 April 2005
Resolution: Observed proper flares.
Engineering › Fuel Oil Service System › Filter
Issued 17 March 2005 Resolved
PROVIDE AND INSTALL FLAME IMPINGMENT DEVICES ON BOTH FUEL FILTERS.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2005
Resolved 15 April 2005
Resolution: Observed flame impingment device.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 17 March 2005 Resolved
PROVIDE COPY OF 2004 MIS REPORT.
Condition: Unknown
Due 1 April 2005
Resolved 22 March 2005
Engineering › Fuel Oil Service System
Issued 15 May 2003 Resolved
Install proper fuel oil and hise fittings IAW 182.720. LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2003
Resolved 27 June 2003
Resolution: Sighted digital photos of valves installed.
Engineering › Fuel Oil Service System
Issued 15 May 2003 Resolved
Install emergency fuwl oil shuttoff valves IAW 46 CFR 176.804 (f). LEGACY COMPONENT DESC: Valve
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2003
Resolved 27 June 2003
Resolution: Sighted digital photos of hose fittings installed and faxed caopy of receipt

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.