MAURY USCG vessel records Sign in
← All vessels

ERIKOUSSA

ERIKOUSSA is a 2003 tank ship. The Coast Guard has recorded 39 inspections since 2003, most recently in August 2020, along with 4 deficiencies and 10 operational controls, 2 with no removal date recorded.

Records from 2003 to 2020. Most recent: inspection, 10 August 2020.

Built
2003
Last inspected
10 August 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
2 with no removal date recorded

Identity

9254850 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
621239
Flag
GREECE
—
Maury page id
psix-621239

Inspections, by type

…with no type recorded16
Years with a record 16 calendar years (2003–2020)
The 39 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it70142 - Dead Weight, Metric Ton
83975 - Displacement, Metric Ton
41679 - Convention (Subpart B), Gross Ton
19343 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 39

10 August 2020 PSC B · COC-TVE Annual
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7029199
16 July 2020 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7007678
8 February 2020 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6905213
23 January 2020 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6894869
13 January 2020 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6887962
13 January 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6888359
17 July 2019 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6750634
15 June 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6714616
29 August 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6526485
4 July 2018 COC-TVE Annual · Ballast Water Examination · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6458632
4 July 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6466388
4 July 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6466699
2 January 2018 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6331169
9 December 2017 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6321429
14 July 2017 COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6208278
11 January 2017 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6068093
20 May 2016 ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5876314
1 August 2014 COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4933380
2 May 2014 ISPS II Exam · Ballast Water Examination · COC-TVE Annual · COE-Dockside
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4840119
26 July 2012 Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 4391370
19 July 2011 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4081059
2 December 2010 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3903239
3 July 2009 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3521983
10 April 2009 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3450490
16 March 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3434518
16 September 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3326062
17 June 2008 Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3233851
18 September 2007 Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3061132
29 March 2007 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2897860
28 May 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2661660
21 May 2006 ISPS II Exam · COC-TVE Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2659606
12 January 2006 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2566000
10 November 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2532794
22 March 2005 COC-TVE Renew · Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2312933
7 March 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2019793
29 October 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1939597
1 June 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1807610
24 May 2003 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1800860
24 May 2003 Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1831066

Deficiency record · 4

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 4 July 2018 Resolved
1830 – (Cargo Transfer)-Each vessel vapor connection flange face must have a permanent stud projecting outward that has a 12.7 millimeter (0.5 inch) diameter and is at least 25.4 millimeters (1 inch) long. It must be located at the top of the flange face, midway between bolt holes, and in line with the bolt hole pattern. PSCO observed missing stud on the forward starboard vapor line flange, and the stud for the starboard aft vapor line was not permanently affixed. Vessel is prohibited from using forward and aft vapor connections on starboard side manifold until corrected. – 46 CFR Part 39.2001 (j) c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 July 2018
Resolution: Recieved pictures from vessel of forward and aft starboard side vapor line flanges. New permanent studs installed by ship's crew on each flange face.
Navigation › Collision/Grounding Avoidance › Radar
Issued 16 March 2009 Resolved
Received inbound Letter of Deviation request for inoperable Secondary Radar. Prior to departure vessel must submit a tech report attesting to the proper operation of the radar. 33CFR164.37(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2009
Resolution: Cleared by technician''s report.
Deck/Cargo › Inert Gas System › Gas Regulating Valve
Issued 16 September 2008 Resolved
The fixed Oxygen Sensor on the IGS reported INOP.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 September 2008
Resolution: Rcvd Lloyds Register class report stating Oxygen sensor replaced, examined and calibrated sat.
Documentation › Safety/Response Plans/Programs
Issued 24 May 2003 Resolved
Provide an approved vessel response plan. Vessel issued one-time VRP waiver for the Houston-Galveston COTP Zone. LEGACY COMPONENT DESC: Vessel Response Plan
Action required: 15 - Rectify deficiencies by next port
Due 24 May 2003
Resolved 30 June 2003

Ownership record