Records from 2012 to 2024. Most recent: inspection, 5 December 2024.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 5 December 2024
Resolved
A vessel not required to have a power driven fire pump must have at least three 2.5 gallon buckets. Vessel is missing 1 fire bucket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 December 2024
Resolved 19 December 2024
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 5 December 2024
Resolved
As appropriate for intended voyage a vessel must carry adequate and up to date charts, coast pilot, light list, tide tables. Light list and currents need to be updated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 December 2024
Resolved 19 December 2024
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 31 October 2024
Resolved
Each EPIRB, other than an EPIRB in a inflatable liferaft, must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. Vessel has an inoperable EPIRB
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2024
Resolution: Vessel has gotten new EPIRB and it's registered.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 May 2020
Resolved
Failure to make vessel available for annual inspection within 3 months before or after each anniversary date of issuance of the COI.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 December 2022
Resolution: Issued new COI
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 January 2020
Resolved
Replace Port and STBD shaft cutlass bearings, both bearings are worn past 50%.
Action required: 705 - Other - as specified
Resolved 26 February 2020
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 3 January 2020
Resolved
Repair/replace Port fuel tank vent screen and hose. Vent found with no flame screen and hose was not designed for petroleum use. Hose shall be designed for use with petroleum and have a wired core. Flame screens must consist of a single screen of corrosion resistant wire of at least 30×30 mesh.
Action required: 705 - Other - as specified
Resolved 26 February 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 December 2019
Resolved
Remove shaft zincs on Port and STBD shafts for Marine Inspector to visually see condition of cuttlas bearings.
Action required: 705 - Other - as specified
Resolved 3 January 2020
Resolution: Inspected, issued additional 835
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 17 December 2019
Resolved
Demonstrate proper operation of raw water intake thru-hull fitting for head. Vessel operator was unable to access the thru-hull valve to demonstrate proper function. during drydock inspection.
Action required: 705 - Other - as specified
Resolved 26 February 2020
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 17 December 2019
Resolved
Repair/replace aft deck area, fiberglass deck was soft and appeared to have delaminated from the plywood. Make deck available for re-inspection prior to laying down new fiberglass.
Action required: 705 - Other - as specified
Resolved 3 March 2020
Resolution: ground down deck, wood core appeared to be in acceptable condition
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 17 December 2019
Resolved
Deck stringers under hull crossover in way of engine room hatches was found to be saturated with water. Make area available for re-inspection to ensure structural integrity of stringers.
Action required: 705 - Other - as specified
Resolved 3 March 2020
Resolution: replaced stringers per plan
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 November 2018
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each space with a through hull fitting below the water line and in machinery space bilge. Vessel bilge high level alarm was not audible or visually indicated at the operating station. Repair high water alarm to be audible and visual at operating station to the satisfaction of the local OCMI/Marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2018
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 20 November 2018
Resolved
A vessel on which a pre-engineered fixed fire extinguishing system is installed must have a means to restart the engines. The starboard engine was unable to restart after actuation of the pre-engineered system to the satisfaction of the local OCMI/Marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 November 2018
Resolved
An adult life jacket must be provided for each person carried on board a vessel. 3 of the life jackets were not in a satisfactory condition. Replace life jackets to meet the specifications in 46 CFR 180.71 (c) to the satisfaction of the local OCMI/Marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2018
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 20 November 2018
Resolved
Each life float must be secured to the vessel by a painter with a float free link permanently attached to the vessel. Vessel did not have a float free link. Install a float free link to the satisfaction of the local OCMI/Marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 December 2018
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 20 November 2018
Resolved
Each life float must have Type II retro-reflective material meeting 46 CFR 164.018. on each side and end. The material must be in strips at least (2 in.) wide extending from top to bottom over the side or end and continuing over the top and bottom surfaces of the apparatus. Life floats reflective tape was inadequate. Replace reflective tape to the satisfaction of the local OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 December 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 November 2018
Resolved
Bilge pumps must be permanently mounted. The bilge pump in the engine room was not permanently mounted. Permanently mount bilge pump in the engine room to the satisfaction of the local OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 December 2018
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 20 November 2018
Resolved
EPIRB must be mounted to allow it to float free. EPIRB is currently mounted under a bench. Remount EPIRB to a location that will permit it to float free.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 December 2018
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 November 2018
Resolved
Machinery spaces must be capable of being vapor tight. The penetrations in the forward bulkhead of the engine room are not vapor tight. Make penetrations in the machinery space vapor tight to the satisfaction of the OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 December 2018
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 20 November 2018
Resolved
Each cylinder in the pre-engineered fixed gas fire fighting system must be hydro-statically tested every 5 years. The cylinder in the port side engine compartment has not been hydro-statically tested in the last 5 years. Hydro-statically test the port side Fireboy cylinder to the satisfaction of the OCMI.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 December 2018
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 November 2018
Resolved
Portable fire extinguishers must be installed in accordance with the manufactures requirements. The portable fire extinguisher located near the head was secured with a line holding in in the bracket. Replace bracket with manufacture approved bracket to the satisfaction of the OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 December 2018
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 20 November 2018
Resolved
Strong and effective rudder stops must be provided to prevent jamming and damage to the rudder and its fittings. Vessel did not have rudder stops. Install rudder stops to prevent damage to rudder and vessel to the satisfaction of the OCMI.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 December 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 November 2018
Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request. Vessel unable to provide current records. Provide current records to the satisfaction of the OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 December 2018
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 20 November 2018
Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station in accordance with Part III of Title III of the Communications Act must carry a radio operator who holds hold a marine radio operator permit or higher class license. Vessel master did not have a marine radio operator permit. Captain must have a marine radio operator permit.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 December 2018
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 20 November 2018
Resolved
The Certificate of Inspection and stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. Vessel did not have documents posted. Post documents to the satisfaction of the OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 December 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 November 2018
Resolved
Exhaust pipes must be suitably insulated. The insulation on the exhaust pipe on the port engine does not fully cover the pipe. Repair/replace lagging on the port exhaust pipe.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 December 2018
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 20 November 2018
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Vessels emergency instructions are not posted and fire procedures are not satisfactory. Ensure all instructions are written IAW 185.512 and posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 December 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 20 November 2018
Resolved
Overboard discharge pipes must have a positive action valve or cock that is located as close as possible to the hull. The overboard discharge valve located amidships on the starboard side was in operable. Repair/Replace valve to the satisfaction of the OCMI.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 December 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 November 2018
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion and machinery failure. Port engine air filter not adequate and repair on coolant tank not satisfactory. Repair/Replace air filter and coolant tank on port engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 December 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 November 2018
Resolved
The owner or operator must conduct all tests as required by the [name withheld] to engine issues, vessel was unable to get underway to conduct drills. Conduct underway drills with Marine inspectors onboard to witness.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 December 2018
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 20 November 2018
Resolved
Any vessel of at least five net tons which engages in coastwise trade, must have a Certificate of Documentation bearing a valid endorsement appropriate for the activity in which engaged. Vessel did not have their COD onboard. Vessel must provide a Certificate of Documentation to the satisfaction of OCMI.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 December 2018
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 20 November 2018
Resolved
A vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible; U.S. Coast Pilot or similar publication; Coast Guard Light List; Tide tables; and Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority. Vessel did not have the required charts and publications onboard. Vessel must have the required and updated charts and publications on board vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 December 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 November 2018
Resolved
VESSEL WAS NOT READY FOR INSPECTION AND HAD NO COPY OF THEIR COI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 November 2018
Resolved 18 December 2018
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 10 July 2017
Resolved
Port Engine does not shutdown during fireboy discharge.
Action required: 705 - Other - as specified
Due 24 July 2017
Resolved 26 July 2017
Resolution: New shutdown solenoid was installed, and tested.
Fire Fighting › Remote Fuel Shutoff › General
Issued 10 July 2017
Resolved
cable that controls the remote fuel shut-off is broken and does not operate.
Action required: 705 - Other - as specified
Due 26 July 2017
Resolved 26 July 2017
Resolution: Cable was replaced and tested all sat.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 10 July 2017
Resolved
4 adult PFD were found not serviceable. Replace.
Action required: 705 - Other - as specified
Due 26 July 2017
Resolved 26 July 2017
Resolution: new PFD were provided, and corrected on the spot.
Lifesaving › Lifefloat › Pendant
Issued 10 July 2017
Resolved
STBD life float has 2 broken life line pendants. Replace.
Action required: 705 - Other - as specified
Due 26 July 2017
Resolved 26 July 2017
Resolution: New pendants were attached.
Lifesaving › Lifefloat › Retroreflective Material
Issued 10 July 2017
Resolved
Both life floats are missing reflective material.
Action required: 705 - Other - as specified
Due 26 July 2017
Resolved 26 July 2017
Resolution: New reflective material was installed.
Lifesaving › Lifefloat › Float-free Link
Issued 10 July 2017
Resolved
Both life floats are missing the float free link, and are not attached to the vessel.
Action required: 705 - Other - as specified
Due 26 July 2017
Resolved 26 July 2017
Resolution: Float free links were provided and properly attached.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 10 July 2017
Resolved
STBD engine RPM gauge is inoperable. repair/renew.
Action required: 705 - Other - as specified
Due 26 July 2017
Resolved 26 July 2017
Resolution: NEw gauges were installed and tested all sat.