This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it32506 - Convention (Subpart B), Net Ton 105850 - Dead Weight, Metric Ton 121809 - Displacement, Metric Ton 56365 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 9
20 May 2019Ballast Water Examination · Deficiency Check · COC-TVE Annual · ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6680311
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 20 May 2019Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Cargo stripping pump shaft packing apears to be leaking; cargo residue on both shafts.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 May 2019
Resolution: Class verified repairs made to stripping and witness satisfactory operational test with no leakage.
Deck/Cargo › Vapor Control Systems › Inerting System
Issued 9 May 2018Resolved
To transfer vapors of a flammable or combustible cargo to a facility regulated by 33 CFR Part 154, a vessels's COC must be endorsed stating the VCS is approved under 46 CFR Part 39. Certification by the vessel's classification society may be presented to the OCMI to obtain the required VCS endorsement. Master could not provide the vapor control system certification letter from classification society.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2018
Resolved 11 June 2018
Resolution: Received class documents from the ISM company operator for clearance of the Vapor Approval Letter deficiency (Activity #6406025): Certificate of Compliance Marine Vapour Control System U.S. Regulation, Approval Letter for Examination of Oil Transfer Procd
Deck/Cargo › Inert Gas System › IGS Blower
Issued 9 May 2018Resolved
TThe system shall be capable of delivering inert gas to the cargo tanks at a rate at least 125% of the maximum rate of discharge capacity of the ship expressed as a volume. The inert gas manual has contradiction as to the fan blower capacity which is stated as "4900 meters cube/hour X 2 sets". It further state the inert gas capacity is "9400 meters cube/hour." The inert gas system operation manual states "note that two fans cannot be operated simultaneously", which reduces the maximum IG capacity to 4900 meters cube/hour. This fact is stated on pages 25, 28, and 29. The vessel under these circumstances is only permitted to discharge one cargo pump at 2500 meters cube/hour with the IG system delivering 4900 meters cube/hour to meet the requirements of 125% maximum discharge capacity.
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 May 2018
Resolution: Vessel is fitted with two 4900 m3/hr blowers to meet the 9400 m3/hr Inert Gas capacity. The maximum discharge capacity is 7500 m3/hr,therefore system meets 125% capacity of the maximum discharge rate.IG Manuals are correct & do not require revisions.