Records from 1996 to 2026. Most recent: inspection, 28 January 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 51
28 January 2026
Excursion Permit
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8302967
25 April 2025
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8127610
23 August 2024
Administrative Inspection · Damage Survey · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7987767
8 July 2024
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7953208
15 November 2022
Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7713432
19 September 2022
COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7557234
8 September 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7554536
18 August 2021
Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7288438
9 September 2020
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7053331
25 March 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6931830
9 September 2019
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6805560
17 September 2018
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6542765
18 April 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6393755
2 September 2017
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6259846
8 September 2016
MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5994959
24 September 2015
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5733522
9 September 2015
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5764800
9 July 2012
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4356248
20 June 2012
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4347852
28 February 2012
Simplified Stability Test
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4262648
12 December 2011
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4206586
12 September 2011
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4140527
20 September 2010
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3854109
15 September 2008
Annual Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3325646
12 May 2008
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3204939
16 July 2007
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2991411
10 July 2006
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2710481
15 May 2006
Hull Examination · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2656274
27 July 2005
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2441038
14 September 2004
Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2196770
28 May 2004
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2102962
24 July 2003
Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1858356
24 July 2002
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1651242
9 May 2002
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1614699
1 April 2002
Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1599581
17 January 2002
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1482205
23 July 2001
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1425166
22 January 2001
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1389310
11 July 2000
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1395502
15 May 2000
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1415357
22 July 1999
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1397209
18 March 1999
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 808777
5 November 1998
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1464139
7 August 1998
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 795953
14 July 1998
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1434744
15 May 1998
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1386260
30 September 1997
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 783270
12 September 1997
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1375108
15 May 1997
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1422851
3 January 1997
Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1099773
23 July 1996
Initial Certification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1400263
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 26 August 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Vessel reported damage to the STBD quarter from an impact with a pier, revealing extensive wood rot. Vessel is not to carry passengers prior to repair, proposed repair and execution thereof shall be to the satisfaction of the marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 April 2025
Resolution: Conducted sea trials after completion of repairs to transom during annual inspection 25APR2025, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 July 2024
Resolved
A vessel of more than 26ft in length, but not more than 65ft, must carry one ring life buoy of not less than 24in in diameter. That ring life buoy must also be fitted with a buoyant, dark color, non-kinking lifeline of at least 60ft in length and at least 5/16in diameter. Vsl ring life buoy found deteriorated, faded and cracking with non-floating line attached, both ring buoy and lifeline in need of replacement.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 July 2024
Resolved 11 July 2024
Resolution: Vsl replaced ring buoy and buoyant line, sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 19 September 2022
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs.
Hull planking on stem, starboard side amidships, and port side of stern at the water line showed signs of deterioration.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2022
Resolved 26 June 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 September 2018
Resolved
At least one life buoy must be fitted with a lifeline that is buoyant, at least 60 feet, non-kinking, a diameter of at least 5/16 inch, a breaking strength of at least 1,124 lbs, and be a dark color if synthetic or a type certified to be resistant to deterioriation from ultraviolet light. Life buoy lifeline not satisfactory for the above requirements. Replace lifeline with a satisfactory line. 46 CFR 180.70(c).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 September 2018
Resolved 5 October 2018
Resolution: Purchased and installed new lifebuoy and life line.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 September 2018
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked. Location not marked for child size lifejackets. Stencil location of child size lifejackets with "Child-size Lifejackets". 46 CFR 180.78(a)(5).
Action required: 705 - Other - as specified
Due 25 September 2018
Resolved 5 October 2018
Resolution: Labeled additional child size life jacket locations
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 September 2018
Resolved
All electrical installations shall be to the satisfaction of the OCMI. 02 wire connectors not of the captive type and wasted. Replace wire connectors with the captive type. 46 CFR 183.01-15(a).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 September 2018
Resolved 5 October 2018
Resolution: Purchased and installed new captive type fittings
Documentation › Logs/Records › Drug Test Records
Issued 4 October 2017
Resolved
Documentation for Drug and Alcohol Testing Program not available for inspection. 46 CFR 16.260
Action required: 705 - Other - as specified
Resolved 9 November 2017
Resolution: Received full documentation of DAPI program.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 4 October 2017
Resolved
There was no record of any crew training available during the inspection. A log must be prepared which includes dates, general training topics, and drills for each crewmember in accordance with 46 CFR 185.420, 185.520, and 185.524.
Action required: 705 - Other - as specified
Resolved 1 November 2017
Resolution: Vessel log contains instructions for logging training and drills.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 October 2017
Resolved
Remove dead end wiring in forward compartment and below operator station and renew wasted grounding wire on battery charger. 46 CFR 183.340
Action required: 705 - Other - as specified
Resolved 9 January 2018
Resolution: Received picture of removed dead end wiring.
Electrical › Electric Supply System (service) › Battery Installation
Issued 4 October 2017
Resolved
Batteries were sitting in several inches of unknown liquid. Hazardous condition must be rectified 176.830
Action required: 705 - Other - as specified
Resolved 1 November 2017
Resolution: Renewed batteries and enclosures
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 4 October 2017
Resolved
Emergency instructions must be posted IAW 46 CFR 185.510
Action required: 705 - Other - as specified
Resolved 1 November 2017
Resolution: Emergency instructions posted
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 4 October 2017
Resolved
Carabiner was fixed directly to light, making it too heavy to float. Light was also fitted with non-approved battery which would prevent light from floating even with carabiner removed. Lifebuoy must be fitted with appropriate equipment to float as designed. 180.70(d)
Action required: 705 - Other - as specified
Resolved 9 January 2018
Resolution: Received picture of correctly installed float light with appropriate batttery.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 5 September 2017
Resolved
Certificate of Inspection expired on 09JUL2017. Vessel operated with passengers onboard from 14JUL2017 to 03SEP2017 without a valid COI. - 46 CFR 176.100(a) - Prior to Carrying Passengers
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 November 2017
Resolution: COI issued 11/1/2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 September 2017
Resolved
First aid kit expired. 46 CFR 184.710
Action required: 705 - Other - as specified
Resolved 1 November 2017
Resolution: First aid kit renewed
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 July 2012
Resolved
Provide proper first aid kit.
Due 24 July 2012
Resolved 24 July 2012
Resolution: Vessel now equipped with proper first aid equipment.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 9 July 2012
Resolved
Ensure proper flame screen/flame arrestor provided in discharge end of fuel vent pipe.
Due 24 July 2012
Resolved 24 July 2012
Resolution: Flame screen provided on fuel vent pipe.
Engineering › Fuel Oil Service System › Filter
Issued 9 July 2012
Resolved
Repair fuel filter leak.
Due 24 July 2012
Resolved 24 July 2012
Resolution: Fuel filter leak repaired.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 9 July 2012
Resolved
Ensure proper function of portable lighting.
Due 24 July 2012
Resolved 24 July 2012
Resolution: Vessel has required number of functioning portable lights on board.
Engineering › Bilge Water Management System › Interface Detector
Issued 9 July 2012
Resolved
Ensure proper function of high level bildge alarm.
Due 17 July 2012
Resolved 24 July 2012
Resolution: Bildge alarm repaired and functioning properly.
Engineering › Steering Gear System › Bracket/Clamp
Issued 12 September 2011
Resolved
Top pulley block on fwd end of steering gear wire arrangement has bad bearing. Needs to be replaced.
Action required: 705 - Other - as specified
Due 23 November 2011
Resolved 22 November 2011
Resolution: Received picture of new pulley installed. All sat
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 15 September 2008
Resolved
No proof of Drug and Alcohol Prevention Program was on board. Provide evidence that the vessel has a Drug and Alcohol Policy and current enrollment in a DHHS approved facility IAW 46CFR16.
Action required: 705 - Other - as specified
Resolved 15 October 2008
Resolution: Faxed proof of drug testing enrollment in a DHHS approved facility.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 September 2008
Resolved
Lifebuoy light is not functioning. Repair lifebuoy light to normal operating condition IAW 46CFR180.70.
Action required: 705 - Other - as specified
Resolved 15 September 2008
Resolution: LIfebuoy light battery was replaced and now fully operational.
Lifesaving › Buoyant Smoke Signals › General
Issued 15 September 2008
Resolved
No orange smoke available. Provide 03 approved orange smoke signaling devices IAW 46CFR180.68.
Action required: 705 - Other - as specified
Resolved 15 September 2008
Resolution: 03 smoke signaling devices onboard.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 15 September 2008
Resolved
Fire extinguishers not serviced annually. Have fire extinguishers serviced and provide evidence of service IAW 46CFR176.810.
Action required: 705 - Other - as specified
Resolved 24 November 2008
Resolution: Fire extinguishers serviced.IAW 46CFR176.810.
Communications › Alarms/Indicators › Bilge Alarm
Issued 15 September 2008
Resolved
The bilge alarm audible warning device was not operable. Repair bilge alarm to normal operating condition IAW 46CFR182.530.
Action required: 705 - Other - as specified
Resolved 4 November 2008
Resolution: Bilge alarm fully functional.
Construction/Loadline › Hull › Transverse Frame
Issued 12 May 2008
Resolved
Repair starboard frame #10 aft of main cabin forward bulkhead.
Condition: Damaged By Earlier Event
Due 13 June 2008
Resolved 16 May 2008
Resolution: Repaired broken frame with a sistered frame.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 16 July 2007
Resolved
Need to service all CO2 Fire Extinguishers onboard vessel prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2007
Resolution: Serviced all CO2 Fire Extinguishers.
Engineering › Bilge Water Management System › Not Operational
Issued 14 September 2004
Resolved
Repair bilge alarm.
Action required: 705 - Other - as specified
Due 14 October 2004
Resolved 8 October 2004
Resolution: Confirmed proper operation of bilge alarm.
Lifesaving › Hand Flares › Expired
Issued 14 September 2004
Resolved
Ensure valid orange smoke signal flares are on board vessel.
Action required: 705 - Other - as specified
Due 14 October 2004
Resolved 8 October 2004
Resolution: Confirmed procurement of new flares.
Lifesaving › Lifebuoys
Issued 24 July 2003
Resolved
Ring buoy has cracks in the body that need to be repaired. The ring buoy also needs new reflective tape.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 July 2003
Construction/Loadline › Hull
Issued 24 July 2003
Resolved
The seam between the shear plank and the next plank on the port side was not properly caulked and needs to be re-caulk.
Action required: 705 - Other - as specified
Due 7 August 2003
Resolved 29 July 2003
Documentation › Markings/Placards
Issued 24 July 2003
Resolved
The vessel must post an emergency broadcast placard.
Action required: 705 - Other - as specified
Due 7 August 2003
Resolved 29 July 2003
Navigation
Issued 12 September 1997
Resolved
Replace stbd aft 6 ft section of steering cable.
Condition: Unknown
Due 12 October 1997
Resolved 30 September 1997
Navigation
Issued 12 September 1997
Resolved
Provide compass deviation card.
Condition: Unknown
Due 12 October 1997
Resolved 30 September 1997
Navigation
Issued 12 September 1997
Resolved
Provide up-to-date charts of operating area.
Condition: Unknown
Due 12 October 1997
Resolved 30 September 1997
Lifesaving
Issued 12 September 1997
Resolved
Provide Life Jacket Donning instructions placard.
Condition: Unknown
Due 12 October 1997
Resolved 30 September 1997
Fire Fighting
Issued 12 September 1997
Resolved
Replace 1 B-1 fire ext with 1 B-2 fire ext.
Condition: Unknown
Due 12 October 1997
Resolved 30 September 1997
Documentation
Issued 23 July 1996
Resolved
PROVIDE PROPOSAL TO REPAIR OVERDRIVEN CAULKING THROGHOUT VESSEL, PROPOSAL TO EMCOMPASS UP TO 2 DRYDOCKING CYCLES. VESSEL REP TO REPORT CONDITION OF CAULKING MONTHLY AND SCHEDULE EXAM OF CAULKING IN 6 MONTHS.
Condition: Unknown
Due 23 July 1996
Resolved 23 July 1996