ALMA

ALMA is a 1891 passenger vessel (inspected). The Coast Guard has recorded 30 inspections since 2004, most recently in March 2025, along with 52 deficiencies — 8 with no resolution recorded — and 5 operational controls, 2 with no removal date recorded.

Records from 2004 to 2025. Most recent: inspection, 19 March 2025.

Built
1891
Last inspected
19 March 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
2 with no removal date recorded

Identity

WDF2845
623714
Flag
UNITED STATES
367432550
Maury page id
psix-623714

Inspections, by type

…past their stated due date8
Years with a record 18 calendar years (2004–2025)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)59.3 ft × 22.6 ft × 5.3 ft
Registered tonnagegross 59 / net 47
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFRED SEIMER · SAN FRANCISCO, CA, UNITED STATES · built 1891
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeBox
Hull configurationMonohull
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it47 - Simplified, Net Ton
59 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDF2845MMSI 367432550 · active · compulsorily equipped · granted 26 November 2019, expires 25 November 2029
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 30

19 March 2025 Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8097792
17 May 2022 Deficiency Check · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7452135
10 December 2021 Hull Examination · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7366140
20 November 2019 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6859377
6 March 2019 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6636622
16 October 2018 COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6561957
8 February 2018 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6358283
1 December 2017 Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6331597
21 March 2017 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6108759
1 March 2017 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6097058
12 January 2017 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6069275
10 January 2017 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6068768
8 April 2016 Examination of Repairs · Plan Review "T" Boat
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5853140
4 December 2015 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5775114
2 June 2014 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4995294
7 June 2012 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4399946
9 December 2011 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4204659
27 January 2011 Examination of Repairs · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3934650
13 December 2010 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3910066
18 February 2009 Hull Examination · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3414673
1 October 2008 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3330756
17 July 2008 Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3327630
11 October 2007 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3077906
27 July 2007 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3009186
12 October 2006 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2803111
14 February 2006 Hull Examination · Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2584904
3 October 2005 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2491759
14 February 2005 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2292237
26 January 2005 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2260108
4 October 2004 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2213402

Deficiency record · 52

11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 21 November 2019 Resolved
A vessel on a lakes, bays, and sounds route must carry three hand red flare distress signals and three hand orange smoke distress signals. All flares on board expired March, 2019. Replace with new distress signals within 7 days.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 November 2019
Resolved 3 December 2019
Resolution: Received receipt from operator showing proof that flares were purchased.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 November 2019 No resolution recorded
No marine employer shall engage or employ any individual to serve as a crew member unless the individual passes a chemical test for dangerous drugs for that employer. Only the master was enrolled in the consortium. Enroll all members of the crew that hold a safety-sensitive position. Please reference the Marine Employers Drug Testing Guidance book for further information. The FAQs discuss volunteers and their enrollment in the program as well.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 November 2019 — due date passed with no resolution recorded
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 21 November 2019 Resolved
Licenses for ship stations will normally be issued for a term of ten years from the date of original issuance or renewal. Station license expires November 25, 2019. Renew station license and provide copy to marine inspector. 47 CFR 80.25(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 November 2019
Resolved 10 December 2019
Resolution: FCC Station License copy provided via email. Effective date on the license provided was 11/26/2019.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 21 November 2019 No resolution recorded
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. Master was unable to provide a copy of a valid medical certificate. Previous medical certificate expired April, 2019. Provide proof of valid certificate to marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2019 — due date passed with no resolution recorded
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 November 2019 No resolution recorded
The master and crew will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. The emergency instruction placard should contain at least the applicable portions of the “Emergency Instructions” listed in 46 CFR 185.512. Limited emergency instructions available for review. Provide emergency instructions that meet 46 CFR 185.510 and 185.512.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2019 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 November 2019 No resolution recorded
Each battery used in an item of lifesaving equipment must be replaced during the annual inspection if the expiration date of the battery has passed. The expiration date of the battery for the waterlight was unknown since it was not labeled and there was no record. Replace and mark with the expiration date from the manufacturer.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 December 2019 — due date passed with no resolution recorded
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 21 November 2019 No resolution recorded
Each ship carrying more than 6 passengers for hire equipped with a radiotelephone station must carry a radio operator who meets the following (1) where the station power does not exceed 250 W carrier power or 1500 w peak envelope power, the radio operator must hold a marine radio operator permit or higher class license (2) where the station power exceeds 250 W carrier power or 1500 W peak envelope power, the radio operator must hold a general radiotelephone operator license or high class license. Operator did not have a marine operator permit. Complete requirements and provide valid radio operator permit to the marine inspector. 47 CFR 80.159
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2019 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 21 November 2019 No resolution recorded
The inspection and maintenance of survival craft shall be logged or otherwise documented for review by the Coast Guard upon request. No record of inspection and maintenance of IBA. Log inspection and maintenance in accordance with 46 CFR 185.702 (d).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2019 — due date passed with no resolution recorded
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 November 2019 No resolution recorded
A vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Charts were from 2013. Replace with new charts.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2019 — due date passed with no resolution recorded
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 21 November 2019 No resolution recorded
Section 33 CFR 151.59 applies to a manned U.S. ship that is 26ft or more in length. Vessel was missing a garbage placard. Mount in accordance with 33 CFR 151.59
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 December 2019 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 October 2018 Resolved
Provide (3) fire buckets labeled with lanyards within 3 days.
Action required: 705 - Other - as specified
Due 19 October 2018
Resolved 19 October 2018
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 October 2018 Resolved
Provide new fwd bilge pump hose or mold connection using heat to ensure proper fit within 3 days.
Action required: 705 - Other - as specified
Due 19 October 2018
Resolved 19 October 2018
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 October 2018 Resolved
Secure generator until you prove proper operation of emergency fuel shutoff.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2018
Resolved 19 October 2018
Resolution: Corrected.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 16 October 2018 Resolved
Prove proper operation of emergency lights.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2018
Resolved 29 October 2018
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 16 October 2018 Resolved
Label main fuel shutoffs at bench, remove CO2 placard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2018
Resolved 29 October 2018
Resolution: Corrected.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 October 2018 Resolved
Provide proper nut retention method for mainstay bolts at next credit drydock.
Action required: 705 - Other - as specified
Due 28 February 2019
Resolved 5 March 2019
Resolution: Nylock nuts installed.
Engineering › Bilge Water Management System › Pump
Issued 8 February 2018 Resolved
Electric bilge pump in the engine room portside was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2018
Resolved 23 May 2018
Resolution: Pump tested satisfactiorly.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 January 2018 Resolved
Vessel did not complete annual inspection within the allowable timeframe; vessel must complete annual prior to carrying passengers for hire IAW 46CFR176.500(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2018
Sail Rigging › Spars › Masthead Hardware and Sheaves
Issued 1 December 2017 Resolved
Provide repair proposal for damage identified around the drift pin of the spring stay band on the topmast.
Action required: 705 - Other - as specified
Resolved 14 December 2017
Resolution: Satisfactory repair completed.
Documentation › Certificates/Documents › Stability Letter
Issued 2 June 2017 Resolved
Move all ballast to locations specified on 2014 stability letter.
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 30 June 2017
Resolution: Ballast is in location of 2014 Stability Test. Stability letter is incorrect.
Engineering › Bilge Water Management System › Valve
Issued 25 May 2017 Resolved
Place positive shutoff valve at through hull for all electric submersible pumps. 46 CFR 182.530(e)(7)
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 7 July 2017
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 25 May 2017 Resolved
Clips on 3 Type I PFDs not connected properly.
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 25 May 2017
Resolution: Fixed on the spot
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 March 2017 Resolved
Vessel shall complete satisfactory dry dock inspection prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 March 2017
Resolved 21 March 2017
Resolution: Completed Drydock
Electrical › Lighting (service) › Outlet Box
Issued 12 January 2017 Resolved
Place all electrical connections for light next to head inside junction boxes or remove light & connections entirely. 46 CFR 183.10-20 (OLD T)
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 7 July 2017
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 January 2017 Resolved
Vessel shall complete annual inspection prior to carrying passengers. 46CFR176.100(a)/46CFR176.500(b)(1)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 January 2017
Resolution: Annual inspection conducted on 12JAN17. Inspection documented in activity # 6069275
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 9 December 2011 Resolved
Provide proof of FCC operator license.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2012
Resolved 28 July 2012
Resolution: Inspected to the satisfaction of the attending Marine Inspector.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 9 December 2011 Resolved
Provide MARPOL placard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2012
Resolved 7 June 2012
Resolution: The placard is onboard and posted.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 December 2011 Resolved
Provide replacement for expired and missing contents for first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2012
Resolved 7 June 2012
Navigation › Piloting/Steering › Marine Charts
Issued 9 December 2011 Resolved
Provide current charts for route.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2012
Resolved 7 June 2012
Resolution: Current charts onboard.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 9 December 2011 Resolved
Provide current edition of light list.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2012
Resolved 7 June 2012
Resolution: Light list onboard
Navigation › Piloting/Steering › Compass Deviation Table
Issued 9 December 2011 Resolved
Provide compass deviation card.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2012
Resolved 28 July 2012
Resolution: Current deviation card onboard.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 December 2011 Resolved
Provide plan for installation of stern light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2012
Resolved 28 July 2012
Resolution: The stern light is installed and working properly.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 9 December 2011 Resolved
Provide/replace batteries for two flashlights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2012
Resolved 7 June 2012
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 9 December 2011 Resolved
Provide CO2 activation instructions in the deck box.
Condition: Improper/Lack of Maintenance
Due 1 March 2012
Resolved 7 June 2012
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 9 December 2011 Resolved
Provide waste management plan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2012
Resolved 7 June 2012
Resolution: Plan onboard.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 9 December 2011 Resolved
Provide copy of company policy with the EAP program.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2012
Resolved 7 June 2012
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 9 December 2011 Resolved
Provide proof of annual servicing of fixed fire fighting system and hand portable extinguisher prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 March 2012
Resolved 7 June 2012
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 9 December 2011 Resolved
Provide proof of replaced reflective tape on 03 adult lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2012
Resolved 28 July 2012
Resolution: Inspected 03 life jackets with the proper amount retro-reflective tape.
Lifesaving › Inflatable Liferafts › Servicing
Issued 9 December 2011 Resolved
Provide proof of annual liferaft servicing and proper installation, prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 March 2012
Resolved 7 June 2012
Resolution: Annual servicing report is now onboard and current.
Navigation › Piloting/Steering › US Coast Pilot
Issued 14 December 2010 Resolved
Provide U.S. Coast Pilot.
Action required: 705 - Other - as specified
Due 14 January 2011
Resolved 12 April 2011
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 14 December 2010 Resolved
Provide Emergency Instructions List
Action required: 705 - Other - as specified
Due 14 January 2011
Resolved 12 April 2011
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 14 December 2010 Resolved
Prove enrollment and compliance with drug testing program (not on board) and random testing requirements.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 April 2011
Resolved 14 December 2010
Lifesaving › Hand Flares › Expired
Issued 14 December 2010 Resolved
Provide a total of 3 Orange flares meeting 160.037 and 3 Red flares meeting 160.021, or as an alternative provide 6 Red flares meeting 160.021.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 April 2011
Engineering › Bilge Water Management System › Pump
Issued 14 December 2010 Resolved
Repair indicator light for the engine room bilge pump. Must show when the bilge pump is operating. 182.530(c).
Action required: 705 - Other - as specified
Due 14 January 2011
Resolved 12 April 2011
Communications › Radio Communications › VHF Radiotelephone
Issued 14 December 2010 Resolved
Provide Marine Radio Operators Permit.
Action required: 705 - Other - as specified
Due 14 January 2011
Resolved 12 April 2011
Construction/Loadline › Hull › Transverse Frame
Issued 18 February 2009 Resolved
Pull and inspect 64 fasteners as indicated on blueprints. Replace and fasten 2 hull planks as indicated on blurprints.
Action required: 705 - Other - as specified
Due 18 March 2009
Resolved 27 February 2009
Resolution: Corrected
Fire Fighting › Fire Bucket › Stenciling
Issued 1 October 2008 Resolved
Label buckets.
Condition: Improper/Lack of Maintenance
Due 1 November 2008
Resolved 10 March 2009
Resolution: Corrected
Engineering › Fuel Oil Service System › Filter
Issued 1 October 2008 Resolved
Provide flame shield for both Port & Stbd fuel oil filter bowels.
Condition: Placed in Improper Service
Due 1 November 2008
Resolved 10 March 2009
Resolution: Corrected
Navigation › Piloting/Steering › US Coast Pilot
Issued 11 October 2007 Resolved
Provide onboard a current copy of: Light List, Coast Pilot, and Nav Rules (I.A.W. 46 CFR 184.420).
Due 15 December 2007
Resolved 26 October 2007
Resolution: Received invoice by email.
Engineering › Bilge Water Management System › Pump
Issued 3 October 2005 Resolved
Prove proper operation of fwd bilge pump.
Action required: 705 - Other - as specified
Resolved 3 October 2005
Construction/Loadline › Hull › Hull Plating
Issued 26 January 2005 Resolved
Vessel shall perform underway sea trials with a USCG marine inspector in attendance prior to operating with passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 February 2005
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 4 October 2004 Resolved
Exsive shaft packing leaking on STBD shaft
Due 4 October 2004
Resolved 4 October 2004
Resolution: Corrected on the spot