MAURY USCG vessel records Sign in
← All vessels

ABIGAIL

ABIGAIL is a 2003 passenger vessel (inspected). The Coast Guard has recorded 31 inspections since 2005, most recently in June 2026, along with 24 deficiencies — 1 with no resolution recorded — and 2 casualty investigations between 2021 and 2023.

Records from 2005 to 2026. Most recent: inspection, 3 June 2026.

Built
2003
Last inspected
3 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB4715
623796
Flag
UNITED STATES
366901530
Maury page id
psix-623796

Inspections, by type

…with no type recorded3
Years with a record 16 calendar years (2005–2026)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)48.0 ft × 16.0 ft × 7.5 ft
Registered tonnagegross 38 / net 30
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWINNINGHOFF BOATS INC · ROWLEY, MA, UNITED STATES · built 2003
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it30 - Simplified, Net Ton
38 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ3531MMSI 366901530 · active · compulsorily equipped · granted 6 May 2025, expires 6 May 2035
WDB4715MMSI 366901530 · expired · compulsorily equipped · granted 27 June 2013, cancelled 16 September 2023
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 31

3 June 2026 Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8390925
22 July 2025 Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8191718
1 May 2025 Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8124107
5 June 2024 Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7926723
8 April 2024 Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7905519
14 March 2024 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7881535
8 November 2023 Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7818568
24 October 2023 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7815049
22 May 2023 Annual Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7680193
11 April 2023 Deficiency Check · Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7663305
28 March 2022 COI Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7415774
2 November 2021 Examination of Repairs · Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7344440
27 October 2021 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7351736
29 April 2021 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7185702
23 March 2021 Hull Examination · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7161431
23 April 2020 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6952464
9 May 2019 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6679965
28 March 2019 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6650659
13 September 2018 Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6539516
19 April 2018 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6394386
11 April 2017 Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6121839
23 March 2017 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6109684
30 March 2016 Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5843713
3 February 2016 Construction Oversight
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5808794
7 July 2011 Simplified Stability Test
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4072786
24 April 2009 Type not recorded
No type recorded · Station Point Allerton · USCG Northeast District (CGD-NE) · Activity 3460072
30 March 2009 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3442565
22 July 2008 Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3276860
2 April 2008 Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3175863
11 April 2007 Deficiency Check · Hull Examination · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2905917
23 March 2005 Hull Examination · Plan Review "T" Boat
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2317387

Deficiency record · 24

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 June 2026 No resolution recorded
A vessel of at least 7.9 meters (26 feet) in length must be provided with individual bilge lines and bilge suctions for each watertight compartment. Vessel's lazarette compartment was not equipped with a bilge suction from an installed pump or an individual electrical submersible pump was not installed in the space. O/O to install proper bilge pumping equipment to cover lazarette compartment prior to next credit hull exam. 46 CFR 182.510(a)
Action required: 705 - Other - as specified
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 3 June 2026 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces:(1) A space with a through-hull fitting below the deepest load waterline, such as a lazarette. Vessel did not have an installed high water level alarm in the lazarette. 46 CFR 182.530(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2026
Resolved 31 July 2026
Resolution: O/O installed high water level alarm in the lazarette w/ audible and visual alarms.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 June 2026 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station:(1) A light to indicate discharge;(2) An audible alarm that sounds upon discharge; and(3) A means to reset devices used to reset devices used to automatically shut down ventilation systems and engines as required by paragraph (a)(3) of this section. Installed fireboy system only had a visual alarm indicating discharge. O/O to repair/replace fireboy alarm panel to ensure both audible and visual alarms are installed in system. 46 CFR 181.420(b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2026
Resolved 31 July 2026
Resolution: O/O had the machinery space fire boy alarm system panel upgraded to now have audible and visual alarms.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 June 2026 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. 46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 June 2026
Resolved 17 June 2026
Resolution: O/O renewed first aid kit.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 May 2025 Resolved
The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection, but must not be fewer than the minimum number required by table 1 to § 181.500(b). The 2-A portable extinguisher required for the accommodation space was missing from the bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2025
Resolution: compliant
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 1 May 2025 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2025
Resolved 30 May 2025
Resolution: new license
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 May 2025 Resolved
A ship, except a ship of less than 26 feet in length, must have a placard of at least 5 by 8 inches, made of durable material fixed in a conspicuous place in each machinery space, or at the bilge and ballast pump control station. Crew could not locate an oil pollution placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2025
Resolution: compliant
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 May 2025 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space... The visual indicator light on the engine space bilge high level alarm is inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2025
Resolution: repaired and tested
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 May 2025 Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. The life float is missing a waterlight. Vessel is restricted to carrying passengers during daylight hours and clear visibility, or within one nautical mile from land.
Action required: 705 - Other - as specified
Resolved 13 May 2025
Resolution: replaced with compliant light
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 1 May 2025 Resolved
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. The life float is deteriorated. Provide evidence from the life float manufacturer that the life float is still serviceable, or replace the life float prior to the 2026 Annual Inspection.
Action required: 705 - Other - as specified
Due 26 June 2026
Resolved 3 June 2026
Resolution: O/O made repairs to life float IAW manufacturer's instructions.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 8 November 2023 Resolved
Repairs to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. O/O informed Sector Boston of damage suffered to the STBD running gear of vessel. Upon out of water inspection, marine inspectors and O/O found the STBD inboard strut support weld had broken away from the bottom hull plate and severe damage was observed on all blades of the propeller. O/O is to provide OCMI with a repair action plan detailing the steps to be taken to complete all necessary repairs and await approval prior to beginning work on vessel.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 December 2023
Resolved 27 November 2023
Resolution: Recieved satisfactory repair proposal from Greg Jones. All sat.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 8 November 2023 Resolved
The marine inspector may require any part or all of the propeller shafting to be drawn for examination of the shafting and stern bearing whenever the condition of the shafting and bearing are in question. Vessel experienced damage that broke the weld connecting the STBD strut to the bottom plating of the hull. STBD shaft is to be pulled for full inspection of shafting and condition of bearings.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 December 2023
Resolved 10 April 2024
Resolution: VSL completed repairs and completed Sea Trials. All sat.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 May 2019 Resolved
The master of the vessel shall ensure that the EPIRB's battery is replaced before the date required by FCC. Battery of EPIRB was expired. Vessel is restricted from operating past 3nm from shore until battery is replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2019
Resolved 29 May 2019
Resolution: Battery was renewed.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 September 2018 Resolved
Vsl is broadcasting NAME with Vsl type precursor (NAME must not include Vsl type precursors, e.g. F/V, M/V)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 27 March 2019
Resolution: While running a query in VIVS, all information had been updated and AIS was broadcasting the proper information.
Stability › Watertight Integrity › General
Issued 11 April 2017 Resolved
04 holes in engine room aft bulkhead and 01 hole in engine room forward bulkhead.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 25 April 2017
Resolved 26 April 2017
Resolution: Satisfactorily examined closing and sealing of all holes in engine rooma aft bulkhead. Bolted on aluminum plates and fire stop were used to close and seal the holes.
Communications › Radio Communications › EPIRB
Issued 11 April 2017 Resolved
Hydrostatic release for EPIRB is expired. Vsl restricted to three miles from shore until valid hydrostact release is installed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 April 2017
Resolved 26 April 2017
Resolution: New EPIRB HRU installed.
Documentation › Certificates/Documents › Permit, Other
Issued 30 March 2016 Resolved
Operator did not have his FCC Operator's License onboard. Provide proof of FCC operator's permit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 April 2016
Resolved 5 April 2016
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 March 2016 Resolved
Anchor light was burnt out.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 April 2016
Resolved 5 April 2016
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 30 March 2016 Resolved
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 April 2016
Resolved 5 April 2016
Engineering › Fuel Oil Service System › Hose
Issued 2 April 2008 Resolved
F/O hoses on MDE not to SAE standards.
Action required: 705 - Other - as specified
Due 16 April 2008
Resolved 21 May 2008
Resolution: Hoses replaced
Lifesaving › Lifefloat › Serviceable
Issued 2 April 2008 Resolved
Repair cracks on exterior of lifefloat, replace retro, re-tie hand lines
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 21 May 2008
Resolution: LF repaired
Lifesaving › Lifebuoys › Serviceable
Issued 2 April 2008 Resolved
Repair small dig in body of ring bouy
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 21 May 2008
Resolution: RB repaired
Navigation › Piloting/Steering › Deviation Table/Graph
Issued 2 April 2008 Resolved
No deviation table on-board, provide same
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 21 May 2008
Resolution: Compass swung, deviation card issued
Engineering › Bilge Water Management System › Interface Detector
Issued 26 April 2007 Resolved
Prior to carrying passengers, repair bilge alarm system.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2007
Resolved 30 April 2007
Resolution: Tested the bilge alarm system, test sat.

Casualty record · 2

27 October 2021Routine · role: Involved in a Marine Casualty · activity 7351736
24 October 2023Routine · role: Involved in a Marine Casualty · activity 7815049
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.