MAURY USCG vessel records
← All vessels

SMILE HIGH II

SMILE HIGH II is a 2003 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 2016, most recently in February 2026, along with 8 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 24 February 2026.

Built
2003
Last inspected
24 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDF6923
623869
Flag
UNITED STATES
Maury page id
psix-623869

Inspections, by type

Years with a record 11 calendar years (2016–2026)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)31.0 ft × 10.5 ft × 6.0 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS INC · CAPE MAY COURT HOUSE, NJ, UNITED STATES · built 2003
Hull materialFRP (Fiberglass)
PropulsionDiesel Outdrive
Hull shapeShip
Hull configurationMonohull
Hailing portDESTIN, FL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 17 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it10 - Simplified, Net Ton
13 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 19

24 February 2026 Vessel Attendance · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8309462
20 January 2026 Annual Inspection · Vessel Attendance · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8299561
10 February 2025 COI Inspection · Spot Check · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8077390
29 August 2024 Administrative Inspection · Special
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7992197
5 June 2024 Administrative Inspection · Special Consideration
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7927701
7 February 2024 Drydock Exam · Examination of Repairs · Annual Inspection · Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7859876
27 February 2023 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7643302
9 March 2022 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7409504
9 February 2022 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7394338
27 April 2021 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7183051
23 March 2020 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6930479
21 January 2020 Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6893364
12 March 2019 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6641791
19 October 2018 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6570663
15 March 2018 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6368925
13 February 2018 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6350516
21 March 2017 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6111203
14 April 2016 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5847233
4 February 2016 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5809188

Deficiency record · 8

11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 March 2022 Resolved
Inspect life saving appliances in accordance with 46 CFR 176.808. Unsatisfactory retro reflective tape on ring bouy.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2022
Resolved 27 February 2023
Resolution: New tape on ring buoy
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 9 March 2022 Resolved
Comply with requirements of FCC in accordance with 46 CFR 184.502. DSC VHF radio function was not programmed correctly.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2022
Resolved 27 February 2023
Resolution: Verified DSC was working
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 March 2022 Resolved
Inspect navigation lights in accordance with 46 CFR 176.816. Port and stbd navigation lights were extinguished.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 March 2022
Resolved 27 February 2023
Resolution: Nav Lights were working properly.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 April 2021 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2021
Resolved 4 May 2021
Resolution: Received photographic proof from vessel owner.
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 21 March 2017 Resolved
Parasail Arch reweld cracked welds.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2017
Resolved 12 April 2017
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 March 2017 Resolved
Renew the all around white light. Nav and anchor combined.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 12 April 2017
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 21 March 2017 Resolved
FWD Hand rail re-fasten to deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 12 April 2017
Engineering › Bilge Water Management System › Not Operational
Issued 21 March 2017 Resolved
Battery compartment repair or replace the Bilge Pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2017
Resolved 21 March 2017
Resolution: repair complete...