DISCOVERY

DISCOVERY is a 2003 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2016, most recently in May 2026, along with 13 deficiencies, 1 operational control and 1 casualty investigation in 2013.

Records from 2013 to 2026. Most recent: inspection, 13 May 2026.

Built
2003
Last inspected
13 May 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDB4622
624120
Flag
UNITED STATES
Maury page id
psix-624120

Inspections, by type

…with no type recorded1
Years with a record 11 calendar years (2016–2026)
The 16 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it4 - Simplified, Net Ton
4 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 16

13 May 2026 Drydock Exam · Deficiency Check · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8374022
12 August 2025 Deficiency Check · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 8209429
8 October 2024 Type not recorded
No type recorded · USCGC WILLIAM HART (WPC 1134) · USCG Oceania District (CGD-O) · Activity 8018737
30 May 2024 Hull Examination · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Lihue · USCG Oceania District (CGD-O) · Activity 7926649
14 June 2023 COI Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7714696
18 July 2022 Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7522535
13 June 2022 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7476488
14 February 2022 Examination of Repairs · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7398579
29 March 2021 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7165905
7 December 2020 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7107637
9 June 2020 Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6973214
19 July 2019 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6755443
25 June 2018 COI Inspection · Administrative Inspection · DAPI Audit · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6455517
14 June 2017 DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6189807
5 July 2016 Hull Examination · Annual Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5933093
24 March 2016 Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5840677

Deficiency record · 13

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 May 2026 Resolved
The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant OCMI, but must be not less than the minimum number required by table 46 CFR 181.500(a) Vessel missing 01 10-B:C at operating station. Provide 01 portable extinguisher. 46 CFR 181.500(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2026
Resolved 29 June 2026
Resolution: New extinguisher provided.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 13 May 2026 Resolved
All equipment must be installed and maintained in such a manner as to afford adequate protection from personal injury. T-top has broken free from frame on port side forward mounting location. Provide repair to make t-top secure to mounting location. 46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2026
Resolved 29 June 2026
Resolution: T-top secured with u-bolts.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 May 2026 Resolved
All equipment must be installed and maintained in such a manner as to afford adequate protection from personal injury. Missing 05 bolts for collar attachment to hull. Provide all bolts for collar attachment. 46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2026
Resolved 9 July 2026
Resolution: All bots attached.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2026 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Rusted flexible fuel vent hose in forward helm cabin. Renew hoses. 46 CFR 182.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2026
Resolved 29 June 2026
Resolution: New piping installed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 August 2025 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Bilge pump indicator at helm not operational. Provide visual indicator for bilge pump. 46 CFR 182.530(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2025
Resolved 9 September 2025
Resolution: Auto bilge pump indicator operational.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 12 August 2025 Resolved
A red warning sign at the switch must state that the blowers must be operated prior to starting the engines for the time sufficient to insure at least one complete change of air in the space served. Calculate time for air change based on volume of space and output of blower and post signage. 46 CFR 182.460(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2025
Resolved 12 October 2025
Resolution: New sign posted.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 August 2025 Resolved
Exhaust blower switches must be of the type interlocked with the starting switch and the ignition switch so that the blowers are started before the engine starter motor circuit or the engine ignition is energized. Vessel did not have interlock for starting and ignition switch. Provide interlock with starting switch and the ignition switch for gasoline fuel tank space blowers. 46 CFR 182.460(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2025
Resolved 12 October 2025
Resolution: Blower hooked up to batteries and turn on when battery switch is turned on.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 August 2025 Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018. 01 life ring buoy on board vessel is missing Type II retroreflective material. Add/replace retroreflective type material on life ring buoy. 46 CFR 185.604(i)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2025
Resolved 9 September 2025
Resolution: Retro tape provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 August 2025 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1 inch high indicating purpose of the valve and direction of operation. Vessels remote fuel shutoff station not labeled. 46 CFR 185.608
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2025
Resolved 9 September 2025
Resolution: Fuel shutoff station marked.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 25 June 2018 Resolved
46 CFR 182.460 requires partially enclosed spaces w/ gasoline tanks be fitted w/ one supply and one exhaust vent. The exhaust vent must be fitted with at least one powered mechanical blower. The vessel does not have the required ventilation ducting or blower. Provide the required ventilation by 31 Dec 2018.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 December 2018
Resolved 11 December 2018
Resolution: Powered ventilation fan installed.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 25 June 2018 Resolved
The installed EPIRB hydrostatic release expired two years after the date placed into service. The installed hydrostatic release had exceeded its expiration date. Provide a new hydrostatic release.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 June 2018
Resolved 26 June 2018
Resolution: A new hydrostatic release was provided prior to the inspection concluding.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 June 2018 Resolved
Ring buoys are required to be marked with the vessel name and hailing port. The provided ring buoy had not distinguishing markings on it. Provide the proper markings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2018
Resolved 26 June 2018
Resolution: The provided ring buoy was properly marked prior to the inspection concluding.
Engineering › Bilge Water Management System › Pump
Issued 24 March 2016 Resolved
Bilge pump faile after vessel took water over transom. Pump was recently replaced and was found to be faulty. Issued No-Sail CG-835 to replace in kind prior to carrying pax.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 March 2016
Resolved 24 March 2016
Resolution: Vessel replaced faulty bilge pump in kind. Completed Operational testing as witnessed by CG Marine Inspector. All items found sat, removed No-Sail CG 835.

Casualty record · 1

26 June 2013Routine · role: Transiting Vicinity of Primary Subject · serious marine incident, as classified · 1 dead · activity 4641227