Records from 2012 to 2025. Most recent: inspection, 29 April 2025.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 September 2024
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury.
Port engine injector connections leaking. Need to be repaired /replaced to CG MI.
46 CFR 182.100 60ac
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 10 September 2024
Resolution: al sat. fitting tightened,
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 September 2024
Resolved
Each fixed power bilge pump must be self-priming. It may be driven off the main engine or other source of power. It must be permanently connected to the bilge manifold and may also be connected to the fire main. If of sufficient capacity, a power bilge pump may also serve as a fire pump.
Bilge line thru aft bulkhead was extremely rusted corroded and had a hole through it. Need to be repaired /replaced to CG MI.
46 CFR 182.520(c) 60c
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 December 2024
Resolution: Bilge pump replaced, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 September 2024
Resolved
A vessel must be provided with a main steering gear that is:Of adequate strength and capable of steering the vessel at all service speeds.
Fittings were corroded. Need to be repaired /replaced to CG MI.
46CFR182.610 (a)(1) 60c
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 December 2024
Resolution: Steering fittings replaced, all sat.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 9 September 2024
Resolved
...Stations in the maritime service must be licensed by the FCC either individually or by fleet.
Provide copy of Vessel station license.
47CFR.80.13(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2024
Resolved 19 December 2024
Resolution: Station license updated all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 September 2024
Resolved
Except as otherwise provided in paragraphs (b), (c), (d), and (e) of this section, all engines must be water cooled and meet the requirements of this paragraph.
The engine head, block, and exhaust manifold must be water-jacketed and cooled by water from a pump that operates whenever the engine is operating.
Cooling system on generator is leaking out of expansion tank. Repair / replace to satisfaction of CG MI.
16c
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2024
Resolved 10 September 2024
Resolution: Replaced dripless shaft seal. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 9 September 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:Charts of large enough scale to make safe navigation possible;
Make available updated charts to C.G Inspector
46 CFR 184.420 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2024
Resolved 19 December 2024
Resolution: Charts updated, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 September 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions.
Vessel needs proper first aid kit.
46CFR184.710 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2024
Resolved 11 September 2024
Resolution: Replaced first aide kit
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 September 2024
Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each lifeline on a ring life buoy must:
(5) Have a breaking strength of at least 5 kilonewtons (1,124 pounds)
Lifeline and life buoy were worn and need to be replaced to satisfaction of CG MI.
46CFR180.70(c)(5) 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2024
Resolved 11 September 2024
Resolution: grabline and line replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Decision-Support System for Masters on Pass. Ships
Issued 9 September 2024
Resolved
No marine employer shall engage or employ any individual to serve as a crew member unless the individual passes a chemical test for dangerous drugs for that employer.
Master was not listed on consortium. Provided vessel with DAPI audit check sheet. Make all check sheet items available.
46 CFR16.210 (a) 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2024
Resolved 11 September 2024
Resolution: Added [name withheld] to the consortium
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 September 2024
Resolved
Provide services necessary for safety under normal and emergency conditions. Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Minimize accidental personnel contact with energized parts; and Prevent electrical ignition of flammable vapors.
MI’s identified cut cables, cables must be terminated, 110 receptacles need to be replaced. Open wiring within engine room. Need to be repaired /replaced to CG MI
46 CFR 183.200 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2024
Resolved 10 September 2024
Resolution: Wiring covered. all sat. Adam provided pictures
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 September 2024
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets.
Child and adult life jackets need to be separated.
46 CFR 180.78(a)(5) 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2024
Resolved 11 September 2024
Resolution: Child and adult life jackets separated & properly labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 September 2024
Resolved
a) An adult life jacket must be provided for each person carried on board a vessel.
MI's found 55 life jackets on board , the vessel is able to carry 62 people.
Replace missing life jackets.
46CFR180.71 (a) 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2024
Resolved 11 September 2024
Resolution: Replaced missing life jackets. 64 total
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 September 2024
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests: Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew.
Create logbook or get monthly inspection tag
46CFR176.810(b)(ii) 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2024
Resolved 11 September 2024
Resolution: Logged inspection of portable fire extinguisher
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 9 September 2024
Resolved
When using DSC techniques, coast stations and ship stations must use maritime mobile service identities (MMSI) assigned by the Commission or its designees.
Vessel did not have MMSI in radio enter vessel info.
47CFR80.103(b)
16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2024
Resolved 19 December 2024
Resolution: MMSI input, all sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 September 2023
Resolved
On a vessel of at least 7.9 meters in length, a visual and audible alarm must be provided at the operating station to indicate a high water level.
46 CFR 182.530(a)
Demonstrate audible and visual indication for all high water alarms.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 September 2023
Resolved 10 September 2023
Resolution: All high water alarms provide visual and audible indication.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 5 September 2023
Resolved
A vessel must comply with the applicable requirements for any radio and EPIRB installations, including the requirements for a station license and installation.
46 CFR 184.502
Demonstrate proper functionality of radio.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 September 2023
Resolved 10 September 2023
Resolution: VHF radio test sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 September 2022
Resolved
Lights for high level bilge alarms for tank room and engine room were not working. Replace light bulbs. 46CFR182.530(c)
Action required: 705 - Other - as specified
Due 16 September 2022
Resolved 14 September 2022
Resolution: received video evidence of the lights working properly.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 September 2022
Resolved
Dead end wiring under the console in the wheelhouse need to be capped or removed. 46CFR183.340
Action required: 705 - Other - as specified
Due 16 September 2022
Resolved 15 September 2022
Resolution: picture evidence of dead end wiring removal reviewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 September 2022
Resolved
01 child life jacket missing in wheelhouse. Replace missing life jacket. 46CFR180.71(b)(1)
Action required: 10 - Deficiency Rectified
Due 16 September 2022
Resolved 13 September 2022
Resolution: child life jacket was replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 September 2022
Resolved
Starboard side ring buoy missing name. Stencil name with proper size lettering. 46CFR180.70(b)(1)
Action required: 10 - Deficiency Rectified
Due 16 September 2022
Resolved 13 September 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 June 2020
Resolved
The fuel shut off valve must be manually operable from outside the space. Port fuel shutoff valve stem has broken off threads. Repair or replace valve.
46 CFR 182.455(b)(4)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2020
Resolved 17 June 2020
Resolution: inspectors onboard verified rectified deficiency
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 15 June 2020
Resolved
Lifefloat requires servicing for deteriorated grab lines and lifelines as well as SOLAS retro reflective tape. Life float paddles need to be labeled with vessel name.
46 CFR 180.200(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2020
Resolved 17 June 2020
Resolution: inspectors onboard verified rectified deficiency
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 15 June 2020
Resolved
A visual and audible alarm to indicate high water level must be provided at the operating station. Visual alarms for high water level were not functioning.
46 CFR 182.530(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2020
Resolved 17 June 2020
Resolution: inspectors onboard verified rectified deficiency
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 June 2020
Resolved
A vessel must be provided with satisfactory arrangement for draining any watertight compartments. Demonstrate that the installed bilge system is capable of draining watertight spaces.
46 CFR 182.500(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2020
Resolved 17 June 2020
Resolution: inspectors onboard verified rectified deficiency
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 June 2020
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards. Remove dead end wires throughout the vessel. Remove extension cord from water heater.
46 CFR 183.200
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2020
Resolved 17 June 2020
Resolution: inspectors onboard verified rectified deficiency
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 15 June 2020
Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape. Emergency lighting in galley space was not functioning and lights need to be secured to fixture
46 CFR 183.432
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2020
Resolved 17 June 2020
Resolution: inspectors onboard verified rectified deficiency
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 June 2020
Resolved
Portable extinguisher at operating station was not present. Provide all required fire extinguishers.
46 CFR 181.500
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2020
Resolved 17 June 2020
Resolution: inspectors onboard verified rectified deficiency
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 15 June 2020
Resolved
Each vessel that operates beyond 3 miles must have an EPIRB. EPIRB battery is expired and requires servicing.
46 CFR 180.64
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2020
Resolved 17 June 2020
Resolution: inspectors onboard verified rectified deficiency
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 June 2020
Resolved
Each connection to a conductor or terminal part of a conductor must be made in an enclosure. Wire connection to pump in lazarette needs to be out of the bilge.
46 CFR 180.340(g)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 June 2020
Resolved 17 June 2020
Resolution: inspectors onboard verified rectified deficiency
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 June 2020
Resolved
Seal bulkhead penetrations between lazarette and engine room.
46 CFR 179.320
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2020
Resolved 17 June 2020
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 15 June 2020
Resolved
An exposed hazard must be properly protected by a cover. Replace cover for generator belt.
46 CFR 177.960
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2020
Resolved 29 June 2020
Resolution: Guard provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 June 2020
Resolved
All griddles must be fitted with a grease extraction hood in compliance with 181.425. Griddle was not installed with extraction hood. Either remove griddle or provide extraction hood.
46 CFR 181.405(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2020
Resolved 17 June 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 June 2020
Resolved
A generator designed for 40 degrees C may be used in 50 degrees C ambient locations provided the generator is derated to 80 percent of the full load rating. Generator must be derated.
46 CFR 183.320(b)(2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2020
Resolved 17 July 2020
Resolution: Manufacturer's 50deg celsius nameplate installed on generator motor. Manufacture stated motor rated for 50deg celsius.
Operations/Management › Drug and Alcohol Testing › Testing, Substances
Issued 17 May 2018
Resolved
Alcohol Test Strips Expired.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2018
Resolved 5 July 2018
Resolution: Alcohol test strips were replaced.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 19 April 2016
Resolved
Replace as original center pilothouse window.46CFR177.1010
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2016
Resolution: new window installed.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 19 April 2016
Resolved
Conduct man over board and fire drills underway. 46CFR185.520
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2016
Resolution: conducted satisfactory drills
Electrical › Electric Supply System (service) › Battery Installation
Issued 19 April 2016
Resolved
Remove wing nuts on bettery terminals and replace with lock, wash or nut. 46CFR183.354
Condition: Improper Installation
Due 26 April 2016
Resolved 21 April 2016
Resolution: wing nuts replaced with approved nuts, terminals cleaned.
Electrical › Electric Supply System (service) › Cable
Issued 19 April 2016
Resolved
Remove all dead end wiring in engine space. 46CFR183.340
Condition: Improper Installation
Due 26 April 2016
Resolved 21 April 2016
Resolution: all dead end wiring removed