GYPSY BLOOD

GYPSY BLOOD is a 2003 passenger vessel (inspected). The Coast Guard has recorded 34 inspections since 2003, most recently in May 2026, along with 58 deficiencies and 4 casualty investigations between 2008 and 2016.

Records from 2003 to 2026. Most recent: inspection, 4 May 2026.

Built
2003
Last inspected
4 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDE8995
625121
Flag
UNITED STATES
367412140
Maury page id
psix-625121

Inspections, by type

…with no type recorded5
Years with a record 19 calendar years (2003–2026)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)50.0 ft × 16.0 ft × 6.0 ft
Registered tonnagegross 32 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderEVANS BOAT REPAIR INC · CRISFIELD, MD, UNITED STATES · built 2003
Hull materialFRP (Fiberglass)
PropulsionDiesel
Hull shapeShip
Hull configurationMonohull
Hailing portPOINT PLEASANT, NJ
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it25 - Simplified, Net Ton
32 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE8995MMSI 367412140 · active · compulsorily equipped · granted 1 March 2019, expires 28 May 2029
WDB4647MMSI 366900780 · expired · compulsorily equipped · granted 4 July 2003, cancelled 7 September 2013
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 34

4 May 2026 Vessel Attendance · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8359396
2 May 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8127460
12 March 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8092306
13 May 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7906064
1 May 2023 COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7678528
14 March 2023 Internal Structural Exam · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7651503
15 October 2022 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7580521
2 May 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7442105
24 November 2021 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7357181
6 November 2021 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7346366
3 May 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7188414
26 March 2021 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7163292
4 May 2020 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6950749
27 March 2019 Internal Structural Exam · Annual Inspection · Administrative Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6650098
27 April 2018 DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6400939
10 April 2017 Internal Structural Exam · Annual Inspection · Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6119232
19 August 2016 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5977760
25 July 2016 Type not recorded
No type recorded · Station Manasquan Inlet · USCG East District (CGD-E) · Activity 5953727
2 May 2016 Internal Structural Exam · Administrative Inspection · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5866966
5 May 2014 Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4865334
26 March 2010 DAPI Audit
Administrative · USCG East District (dp) · USCG East District (CGD-E) · Activity 3703480
23 March 2010 Annual Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3698221
27 April 2009 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3461891
29 August 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3312157
10 August 2008 Type not recorded
No type recorded · Station Manasquan Inlet · USCG East District (CGD-E) · Activity 3295347
19 July 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3276083
6 May 2008 COI Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3199269
25 January 2007 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2861553
3 November 2005 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2526429
28 July 2005 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2440935
14 October 2004 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2195325
15 September 2003 Plan Review "T" Boat · COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1901749
9 July 2003 Hull Examination · Simplified Stability Test
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1855967
23 May 2003 Plan Review "T" Boat
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1883084

Deficiency record · 58

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 May 2026 Resolved
This part contains requirements for the design, construction, installation, and operation of propulsion and auxiliary machinery, steering apparatus, and associated safety systems. Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. MI observed during steering check the starboard rudder post plate was cracked. When operator turned to port then starboard MI witnessed the plate rose with pressure causing water to enter space. O/O shall proceed to repair facility to be hauled out of water to replace the starboard plate. O/O shall notify MI when repairs have been made to conduct underway steering test to satisfaction of MI.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 May 2026
Resolution: Rudder plate was replaced to satisfaction of MI.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 May 2026 Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate high water level. MI observed the high water level alarm for the forward compartment audible alarm was faint and light flickered. O/O shall repair high level water alarm to satisfaction of attending MI.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2026
Resolution: Bilge alarm worked as designed and to satisfaction of MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 May 2026 Resolved
Connections must be made to battery terminals with a permanent type connectors. Spring clips or other temporary type clamps are prohibited. MI observed four battery in tray had mixture nuts and wing nuts. O/O shall replaced wing nuts with permanent type connector to satisfaction of MI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2026
Resolved 14 May 2026
Resolution: Met requirements to reg. and satisfaction of attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 May 2026 Resolved
Where flexibility is necessary, a section of flexible metallic hose may be used. Nonmetallic hose may be used for wet exhaust systems provided it is especially adapted to resist the action of oil, acid, and heat, has a wall thickness sufficient to prevent collapsing, and double clamped where practicable. MI observed area on hose where one clamp was used for wet exhaust. O/O shall add another clamp to satisfaction of MI.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2026
Resolved 14 May 2026
Resolution: Met to satisfaction of MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 May 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: operation of the main propulsion machinery both ahead and astern. Vessel starboard engine failed to start. Make proper repairs to the satisfaction of the OCMI. 46 CFR 176.804
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 May 2025
Resolution: Owner replaced starter on STBD MDE and MI team returned to vessel and verified satiasfactory repairs. MI team got vessel underway to conduct drills
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 May 2024 Resolved
Vessel had excess water in forward compartment. Pump out bilge. 46CFR17.802(a)(7)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2024
Resolution: Water removed from compartment
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2024 Resolved
Starboard main engine fuel oil shut off valve seized open. Replace valve. 46CFR182.455(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2024
Resolved 17 May 2024
Resolution: O/O replaced with new ball valve.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2024 Resolved
Battery chargers must have an ammeter connected in the charging circuit. Three (03) battery chargers do not have ammeters. Install ammeters. 46CFR182.455(b)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2024
Resolved 11 June 2024
Resolution: ammeters installed on battery chargers
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2024 Resolved
Remote fuel shut off not properly labeled. Install proper markings for fuel valves. 46CFR185.608
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2024
Resolved 17 May 2024
Resolution: O/O installed markings for fuel shut off.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 May 2024 Resolved
First-aid kit missing aspirin items. Put aspirin in First-aid kit. 46CFR184.710
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2024
Resolved 17 May 2024
Resolution: O/O purchased new aspirin and place in first aid kit.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2024 Resolved
Face plate on light/receptacle outlet in engine room broken with exposed wiring. Replace face plate. 46CFR183.200(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2024
Resolved 17 May 2024
Resolution: O/O installed new face plate
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 May 2024 Resolved
Bilge high level alarm not working in generator compartment. Repair alarm. 46CFR182.530
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2024
Resolved 12 June 2024
Resolution: Received video of sat operation of visual and audible high water alarm.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 13 May 2024 Resolved
Missing oil pollution placard. Install placard. 33CFR155.450
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2024
Resolved 17 May 2024
Resolution: Verified oil pollution placard placed on bulkhead.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 2 May 2022 Resolved
A section was missing in each gasket for the hatches to the lazarette and the hatch to the engine room. Replace gaskets so hatches on the weather deck are watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2022
Resolved 5 May 2022
Resolution: USCG satisfied with pictures sent.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 2 May 2022 Resolved
There were cables submersed in the bilge in the engine room that could potentially introduce an unsafe condition. Secure cables above the bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2022
Resolved 5 May 2022
Resolution: USCG satisfied with picture sent.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 May 2022 Resolved
The Type II retroreflective tape on the ring lifebuoy was deteriorating. Replace Type II retroreflective tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2022
Resolved 5 May 2022
Resolution: USCG satisfied with picture sent.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 3 May 2021 Resolved
VHF radio is not on its own circuit as required. Provide dedicated circuit with over current protection for VHF radio. 46 CFR 183.392
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2021
Resolved 21 May 2021
Resolution: VHF Radio was placed on its own circuit with an in-line fuse for overcurrent protection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 May 2021 Resolved
Storage space forward of engine room has wire run that has splice as well as connections made outside of enclosure. Replace cable so splice is not needed. Tape wire nuts. Enclose box. 46 CFR 183.340
Action required: 15 - Rectify deficiencies by next port
Due 17 May 2021
Resolved 21 May 2021
Resolution: Old wire was replaced with new wire that had no splices. Connections were made inside appropriate junction box, and twist caps were taped.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 May 2021 Resolved
Vessel is missing 01 fire extinguisher from accommodation space. Replace extinguisher. 46 CFR 181.500
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2021
Resolved 21 May 2021
Resolution: Extinguisher provided.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 May 2021 Resolved
Vessel has installed 02 battery chargers that were not subject to CG plan review. Provide drawing detailing the installation to include bill of materials (part numbers and/or specifications) of chargers, cables, circuit breakers, batteries and connectors. 46 CFR 176.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2021
Resolved 24 November 2021
Resolution: Drawing reviewed. Chargers are plugged into local receptacle.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 26 March 2021 Resolved
VESSEL REQUIRES DRYDOCK INSPECTION PRIOR TO 31MAR2021. MAKE VESSEL AVAILABLE FOR DRYDOCK INSPECTION PRIOR TO CARRYING PASSENGERS. (46CFR176.600)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2021
Resolution: Conducted satisfactory DD/ISE. -GSC
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 8 May 2017 Resolved
Vessel's STBD engine vent closure will not operate/close as designed, must repair to new condition.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2017
Resolution: Vessel fixed the brackets which allows the vent to close properly
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 8 May 2017 Resolved
Vessel's stbd engine has an exhaust leak, must identify and repair to like new condition.
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 16 May 2017
Resolution: Vessel had a blocked/heavily saturated crankcase vent which was leaking oil on the engine for burn off, this was corrected and engine was ran with CGMI
Engineering › Diesel Engine (propulsion-direct drive) › Bedplate
Issued 10 April 2017 Resolved
Must replace aft inboard motor mount on stbd engine, wasted beyond repair.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2017
Fire Fighting › Fire Bucket › Capacity
Issued 2 May 2016 Resolved
EKO01 Provide three 2.5 gallon fire buckets labeled "FIRE BUCKET".
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 24 May 2016
Resolution: Received email from [name withheld] with photo of corrected deficiency.
Lifesaving › Lifebuoys › Serviceable
Issued 2 May 2016 Resolved
EKO02 Replace grab line on ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 24 May 2016
Resolution: Received email from [name withheld] with photo of corrected deficiency.
Communications › Radio Communications › VHF Radiotelephone
Issued 27 April 2009 Resolved
VSL Operator do not have a FCC Marine Operator Permit. Provide a proof of Marine Opeator Permit by 15 May 2009.
Action required: 705 - Other - as specified
Due 15 May 2009
Resolved 6 May 2009
Resolution: VSL opeator sent a copy of FCC Marine Operator Permit exam certificate via fax.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 April 2009 Resolved
Asprin & eye wash solution expired. Provide proof of current asprin and eye wash solution.
Action required: 705 - Other - as specified
Due 15 May 2009
Resolved 1 May 2009
Resolution: VSL owner sent a copy of reciepts for asprin and eye wash solution.
Engineering › Fuel Oil Service System › Filter
Issued 27 April 2009 Resolved
No flame bowl for ship service diesel generator(SSDG) fuel filter housing. Install a flame bowl on SSDG filter housing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2009
Resolution: VSL owner installed a new flame bowl on SSDG fuel filter housing.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 27 April 2009 Resolved
No MF Radio on board. VSL is restricted to 20 nautical miles until a working MF radio is onboard
Action required: 705 - Other - as specified
Resolved 23 June 2009
Resolution: New SSB Radio installed and tested properly.
Construction/Loadline › Hull › Keel
Issued 6 May 2008 Resolved
Repair check in stem area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 May 2008
Resolution: Received picture of repaired area, all sat.
Construction/Loadline › Hull › Side Shell
Issued 6 May 2008 Resolved
Repair anchor check on port bow.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 May 2008
Resolution: Received picture verifying repairs to port bow, all sat.
Construction/Loadline › Hull › Sheerstrake
Issued 6 May 2008 Resolved
Provide repair proposal for stern/transom area and after the proposal is approved repair.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 May 2008
Resolution: Verified repairs to stern/transom deck area, all sat.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 6 May 2008 Resolved
Proved proper operation of MF radio and remove SSB installation. Provide FCC technician report attesting to both. The vessel is restricted to 20 miles or less from shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 June 2008
Resolution: Received fax from FCC Technician stating SSB and MF radio are functioning.
Navigation › Piloting/Steering › Marine Charts
Issued 20 December 2006 Resolved
Provide current coast pilot, light list, and tides/currents tables.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 January 2007
Resolved 3 January 2007
Resolution: Received phone call from Angelo, vessel rep, who stated that nav pubs deficiency corrected and rqd items on board vsl.
Communications › Radio Communications › EPIRB
Issued 20 December 2006 Resolved
Provide valid hydrostatic release for EPIRB. Vessel restricted from operating beyond 3NM until corrected.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 17 May 2007
Resolution: Observed valid hydrostatic release mechanism installed for EPIRB.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 December 2006 Resolved
Install stern light. Vessel restricted from operating from sunset to sunrise until corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 May 2007
Resolution: Observed properly installed stern light.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 20 December 2006 Resolved
Demonstrate proper operation of audible alarm for fixed fire system at operating station prior to operating with passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2007
Resolution: Observed proper operation of fixed f/f system including audible alarm.
Communications › Radio Communications › EPIRB
Issued 3 November 2005 Resolved
Renew/Replace expired hydrostatic release unit for EPIRB. Vessels route restricted to NMT 3 miles until corrected.
Action required: 705 - Other - as specified
Due 3 December 2005
Resolved 26 January 2006
Resolution: Discussion with O/O revealed that the HRU has been renewed. 26JAN06: Attended vessel. Verified that new HRU is onboard (exp. NOV 07).
Lifesaving › Inflatable Liferafts › Servicing
Issued 3 November 2005 Resolved
Provide annual servicing of liferafts. 05DEC05: Extended required due date to 03JAN06. Liferafts have been removed from the vessel and are being serviced. Vessel is drydocked.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 January 2006
Resolved 26 January 2006
Resolution: Attended vessel. Rafts have been serviced (DEC 05) and are on board.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 November 2005 Resolved
Provide original COI for signature and post on board behind glass.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 December 2005
Resolved 26 January 2006
Resolution: Attended vessel. Master produced original COI. COI was endorsed for the second annual inspection (03NOV05) and posted.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 3 November 2005 Resolved
Provide annual servicing on B-II extinguisher in forward space.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 December 2005
Resolved 26 January 2006
Resolution: Master [name withheld] stated that the B-II extinguisher has been serviced and tagged. 26JAN06: Attended vessel. Verified service tags on all extinguishers.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 3 November 2005 Resolved
Post proper numbering to indicate correct lifejacket stowage.
Action required: 705 - Other - as specified
Due 3 December 2005
Resolved 2 December 2005
Resolution: Master [name withheld] stated that proper numbers have been put in place.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 3 November 2005 Resolved
Prove proper operation of starter for port main diesel engine. 05DEC05: Extended required due date to 03JAN06. Engine has been pulled from the vessel and is undergoing repair in a shop. 26JAN06: Attended vessel. Engine has been serviced and has been reinstalled but cannot be tested as vessel is in drydock. Requirement due date extended to 01APR06.
Action required: 705 - Other - as specified
Due 20 December 2006
Resolved 20 December 2006
Resolution: Witnessed satisfactory operation of engine during u/w test ride.
Engineering › Bilge Water Management System › Pump
Issued 3 November 2005 Resolved
Prove proper operation of engine room submersible pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 December 2005
Resolved 2 December 2005
Resolution: Discussion with Angelo Eppolito revealed that the faulty pump has been replaced and was tested satisfcatory.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 3 November 2005 Resolved
Locate source of exhaust leak on port main engine and repair. 05DEC05: Extended required due date to 03JAN06. Engine has been pulled from the vessel and is undergoing repair in a shop. 26JAN06: Attended vessel. Engine has been serviced and has been reinstalled but cannot be tested as vessel is in drydock. Requirement due date extended to 01APR06.
Action required: 705 - Other - as specified
Due 20 December 2006
Resolved 20 December 2006
Resolution: Witnessed satisfactory operation of engine during u/w test ride. Exhaust did not leak. All sat.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 3 November 2005 Resolved
Provide original Certificate of Documentation. 05DEC05: Extended due date to 03JAN06. COD is apparently lost and O/O is in process of renewing. 26JAN06: Attended vessel. NVDC has not issued new COD as of yet. Requirement due date extended to 01APR06.
Action required: 705 - Other - as specified
Due 1 April 2006
Resolved 7 February 2006
Resolution: Received fax from O/O of new COD issued 27JAN06. Expires 31JAN07.
Accommodation/Occupational Safety › Ventilation › General
Issued 28 July 2005 Resolved
Install Ventilation in fuel tank compartment.
Action required: 705 - Other - as specified
Due 28 August 2005
Resolved 12 August 2005
Resolution: Contacted vessel representative [name withheld] ventilation was installed using 2.5 inch PVC pipe with goosenecks. Vents were installed forward/starboard and aft/port sides of the fuel tank space (2 vents total).
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 14 October 2004 Resolved
Annual Servicing of portable extinguishers and fixed system is overdue. Last service was July 2003.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 November 2004
Resolved 24 October 2004
Resolution: Received fax copy of service report for portable and fixed fire extinguishers.
Stability › Water on Deck › General
Issued 14 October 2004 Resolved
Deck drain at forward part of main deck is piped to bilge. Pipe has been capped off. Drain needs to be reconfigured to drain overboard. 21DEC04: O/O stated that vessel is still in yard undergoing maintenance. Expected to be back in water and returning to Barnegat Light by 01JAN05. Extended 835 due date to 08JAN05.
Action required: 705 - Other - as specified
Due 8 January 2005
Resolved 5 April 2005
Resolution: Attended vessel and observed that the deck drain in question has been modified so that it now drains overboard through a fitting on the port side above the waterline. All connections inspected satisfactory.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 14 October 2004 Resolved
No bell on board. Provide minimum 8 inch bell. 21DEC04: O/O stated that vessel is still in yard undergoing maintenance. Expected to be back in water and returning to Barnegat Light by 01JAN05. Extended 835 due date to 08JAN05.
Due 8 January 2005
Resolved 5 April 2005
Resolution: Attended vessel and verified that a new 8" bell is now on board.
Navigation › Piloting/Steering › Gyro Compass
Issued 14 October 2004 Resolved
Proove proper operation of compass light. 21DEC04: O/O stated that vessel is still in yard undergoing maintenance. Expected to be back in water and returning to Barnegat Light by 01JAN05. Extended 835 due date to 08JAN05.
Due 8 January 2005
Resolved 5 April 2005
Resolution: Attended vessel and verified that compass lights (2) are in place and operating satisfactory.
Electrical › Lighting (service) › Lighting Fixture
Issued 14 October 2004 Resolved
Provide globe for light on overhead/main deck. 21DEC04: O/O stated that vessel is still in yard undergoing maintenance. Expected to be back in water and returning to Barnegat Light by 01JAN05. Extended 835 due date to 08JAN05.
Due 8 January 2005
Resolved 5 April 2005
Resolution: Attended vessel and observed that globe is in place on subject light.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 14 October 2004 Resolved
Provide flashlights at operating station and entrances to machinery spaces. 21DEC04: O/O stated that vessel is still in yard undergoing maintenance. Expected to be back in water and returning to Barnegat Light by 01JAN05. Extended 835 due date to 08JAN05.
Due 8 January 2005
Resolved 5 April 2005
Resolution: Attended vessel. O/O provided two new flashlights. Directed master to put batteries in new light and put in place at operating station which he did. Light tested satisfactory. Existing light is in place outside of machinery space.
Fire Fighting › Fire Hoses
Issued 15 September 2003 Resolved
Install hose hanger for fire hose.
Due 25 September 2003
Resolved 7 October 2003
Resolution: Installed hose hanger for fire hose.
Fire Fighting › Fire Hoses
Issued 15 September 2003 Resolved
Stencil "fire hose" on bulkhead where fire hose is stored.
Due 25 October 2003
Resolved 7 October 2003
Resolution: Stenciled "fire hose" on bulkhead.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 15 September 2003 Resolved
Vessel may only be operated by Angelo Eppolito and [name withheld] acting as Master or Deckhand.
Due 15 September 2003
Resolved 14 October 2004
Resolution: Licenses and documentation checked satisfactory as part of routine annual inspection.
Documentation › Certificates/Documents
Issued 15 September 2003 Resolved
Post Stability Letter and COI.
Due 25 October 2003
Resolved 7 October 2003
Resolution: Posted both documents.

Casualty record · 4

19 July 2008Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3276083
31 July 2010Routine · role: Moored/Anchored in Vicinity of Primary Subject · serious marine incident, as classified · 1 dead · activity 3812814
18 March 2012Routine · role: Involved in a Marine Casualty · 1 dead · activity 4268212
19 August 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 5977760
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.