Records from 2008 to 2026. Most recent: inspection, 4 May 2026.
Inspection history · 19
4 May 2026
Vessel Attendance · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8359396
2 May 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8127460
12 March 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8092306
13 May 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7906064
1 May 2023
COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7678528
14 March 2023
Internal Structural Exam · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7651503
15 October 2022
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7580521
2 May 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7442105
24 November 2021
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7357181
6 November 2021
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7346366
3 May 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7188414
26 March 2021
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7163292
4 May 2020
Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6950749
27 March 2019
Internal Structural Exam · Annual Inspection · Administrative Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6650098
27 April 2018
DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6400939
10 April 2017
Internal Structural Exam · Annual Inspection · Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6119232
19 August 2016
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5977760
25 July 2016
Type not recorded
No type recorded · Station Manasquan Inlet · USCG East District (CGD-E) · Activity 5953727
2 May 2016
Internal Structural Exam · Administrative Inspection · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5866966
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 May 2026
Resolved
This part contains requirements for the design, construction, installation, and operation of propulsion and auxiliary machinery, steering apparatus, and associated safety systems. Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. MI observed during steering check the starboard rudder post plate was cracked. When operator turned to port then starboard MI witnessed the plate rose with pressure causing water to enter space. O/O shall proceed to repair facility to be hauled out of water to replace the starboard plate. O/O shall notify MI when repairs have been made to conduct underway steering test to satisfaction of MI.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 May 2026
Resolution: Rudder plate was replaced to satisfaction of MI.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 May 2026
Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate high water level. MI observed the high water level alarm for the forward compartment audible alarm was faint and light flickered. O/O shall repair high level water alarm to satisfaction of attending MI.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 14 May 2026
Resolution: Bilge alarm worked as designed and to satisfaction of MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 May 2026
Resolved
Connections must be made to battery terminals with a permanent type connectors. Spring clips or other temporary type clamps are prohibited. MI observed four battery in tray had mixture nuts and wing nuts. O/O shall replaced wing nuts with permanent type connector to satisfaction of MI.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2026
Resolved 14 May 2026
Resolution: Met requirements to reg. and satisfaction of attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 May 2026
Resolved
Where flexibility is necessary, a section of flexible metallic hose may be used. Nonmetallic hose may be used for wet exhaust systems provided it is especially adapted to resist the action of oil, acid, and heat, has a wall thickness sufficient to prevent collapsing, and double clamped where practicable. MI observed area on hose where one clamp was used for wet exhaust. O/O shall add another clamp to satisfaction of MI.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 May 2026
Resolved 14 May 2026
Resolution: Met to satisfaction of MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 May 2025
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: operation of the main propulsion machinery both ahead and astern. Vessel starboard engine failed to start. Make proper repairs to the satisfaction of the OCMI. 46 CFR 176.804
Action required: 60 - Rectify deficiencies prior to movement
Resolved 8 May 2025
Resolution: Owner replaced starter on STBD MDE and MI team returned to vessel and verified satiasfactory repairs. MI team got vessel underway to conduct drills
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 May 2024
Resolved
Vessel had excess water in forward compartment. Pump out bilge. 46CFR17.802(a)(7)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2024
Resolution: Water removed from compartment
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2024
Resolved
Starboard main engine fuel oil shut off valve seized open. Replace valve. 46CFR182.455(b)(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2024
Resolved 17 May 2024
Resolution: O/O replaced with new ball valve.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2024
Resolved
Battery chargers must have an ammeter connected in the charging circuit. Three (03) battery chargers do not have ammeters. Install ammeters. 46CFR182.455(b)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2024
Resolved 11 June 2024
Resolution: ammeters installed on battery chargers
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 May 2024
Resolved
Remote fuel shut off not properly labeled. Install proper markings for fuel valves. 46CFR185.608
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2024
Resolved 17 May 2024
Resolution: O/O installed markings for fuel shut off.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 May 2024
Resolved
First-aid kit missing aspirin items. Put aspirin in First-aid kit. 46CFR184.710
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2024
Resolved 17 May 2024
Resolution: O/O purchased new aspirin and place in first aid kit.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 May 2024
Resolved
Face plate on light/receptacle outlet in engine room broken with exposed wiring. Replace face plate. 46CFR183.200(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2024
Resolved 17 May 2024
Resolution: O/O installed new face plate
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 May 2024
Resolved
Bilge high level alarm not working in generator compartment. Repair alarm. 46CFR182.530
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2024
Resolved 12 June 2024
Resolution: Received video of sat operation of visual and audible high water alarm.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 13 May 2024
Resolved
Missing oil pollution placard. Install placard. 33CFR155.450
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2024
Resolved 17 May 2024
Resolution: Verified oil pollution placard placed on bulkhead.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 2 May 2022
Resolved
A section was missing in each gasket for the hatches to the lazarette and the hatch to the engine room. Replace gaskets so hatches on the weather deck are watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2022
Resolved 5 May 2022
Resolution: USCG satisfied with pictures sent.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 2 May 2022
Resolved
There were cables submersed in the bilge in the engine room that could potentially introduce an unsafe condition. Secure cables above the bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2022
Resolved 5 May 2022
Resolution: USCG satisfied with picture sent.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 May 2022
Resolved
The Type II retroreflective tape on the ring lifebuoy was deteriorating. Replace Type II retroreflective tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2022
Resolved 5 May 2022
Resolution: USCG satisfied with picture sent.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 3 May 2021
Resolved
VHF radio is not on its own circuit as required. Provide dedicated circuit with over current protection for VHF radio. 46 CFR 183.392
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2021
Resolved 21 May 2021
Resolution: VHF Radio was placed on its own circuit with an in-line fuse for overcurrent protection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 May 2021
Resolved
Storage space forward of engine room has wire run that has splice as well as connections made outside of enclosure. Replace cable so splice is not needed. Tape wire nuts. Enclose box. 46 CFR 183.340
Action required: 15 - Rectify deficiencies by next port
Due 17 May 2021
Resolved 21 May 2021
Resolution: Old wire was replaced with new wire that had no splices. Connections were made inside appropriate junction box, and twist caps were taped.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 3 May 2021
Resolved
Vessel is missing 01 fire extinguisher from accommodation space. Replace extinguisher. 46 CFR 181.500
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2021
Resolved 21 May 2021
Resolution: Extinguisher provided.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 May 2021
Resolved
Vessel has installed 02 battery chargers that were not
subject to CG plan review. Provide drawing detailing the
installation to include bill of materials (part numbers
and/or specifications) of chargers, cables, circuit
breakers, batteries and connectors. 46 CFR 176.700
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2021
Resolved 24 November 2021
Resolution: Drawing reviewed. Chargers are plugged into local receptacle.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 26 March 2021
Resolved
VESSEL REQUIRES DRYDOCK INSPECTION PRIOR TO 31MAR2021. MAKE VESSEL AVAILABLE FOR DRYDOCK INSPECTION PRIOR TO CARRYING PASSENGERS. (46CFR176.600)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 April 2021
Resolution: Conducted satisfactory DD/ISE. -GSC
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 8 May 2017
Resolved
Vessel's STBD engine vent closure will not operate/close as designed, must repair to new condition.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2017
Resolution: Vessel fixed the brackets which allows the vent to close properly
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 8 May 2017
Resolved
Vessel's stbd engine has an exhaust leak, must identify and repair to like new condition.
Action required: 705 - Other - as specified
Due 8 June 2017
Resolved 16 May 2017
Resolution: Vessel had a blocked/heavily saturated crankcase vent which was leaking oil on the engine for burn off, this was corrected and engine was ran with CGMI
Engineering › Diesel Engine (propulsion-direct drive) › Bedplate
Issued 10 April 2017
Resolved
Must replace aft inboard motor mount on stbd engine, wasted beyond repair.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2017
Fire Fighting › Fire Bucket › Capacity
Issued 2 May 2016
Resolved
EKO01 Provide three 2.5 gallon fire buckets labeled "FIRE BUCKET".
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 24 May 2016
Resolution: Received email from [name withheld] with photo of corrected deficiency.
Lifesaving › Lifebuoys › Serviceable
Issued 2 May 2016
Resolved
EKO02 Replace grab line on ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2016
Resolved 24 May 2016
Resolution: Received email from [name withheld] with photo of corrected deficiency.