Records from 2004 to 2026. Most recent: inspection, 2 April 2026.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 April 2026
Resolved
... rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. MIs observed a segment of the railing missing. Reinstall rail within 2 weeks.
46 CFR 177.900 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2026
Resolved 14 April 2026
Resolution: Vessel sent photos showing the new rail installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 April 2026
Resolved
A bilge suction must be fitted with a suitable strainer... MIs observed Port Side Engine Room Bilge strainer not serviceable. Replace strainer in kind.
46 CFR 182.510 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2026
Resolved 14 April 2026
Resolution: Vessel sent photos of newly installed bilge strainer
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 May 2025
Resolved
Each fixed power bilge pump must be self priming. It may be driven off the main engine or other source of power. It must be permanently connected to the bilge maifold and may also be connected to the fire main. Make Port Bow No. 2, Port Engine Room, STBD Engine Room, and STBD Lazarette Bilge Pumps ready for inspection.
46 CFR 182.520(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 May 2025
Resolution: MI def check conducted. Bilge suction sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 May 2025
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indictate a high water level. Port Lazarette bilge alarm light found missing. Repair within 14 days.
46 CFR 182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 July 2025
Resolution: Recieved picture from email by Operator that
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 June 2023
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. Waterlight lanyard on starboard bow ring buoy is deteriorated from ultraviolet light.
46 CFR 180.70(d)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2023
Resolved 15 August 2023
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 12 June 2023
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. Air compressor under the pilot house must be mounted.
46 CFR 176.830(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2023
Resolved 15 August 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 June 2023
Resolved
General design, installation, and maintenance requirements. Extension cord is being used from the Port Engine Room to the Toilet and must be hardwired and must be protected from exposure to chemicals and sewage.
46 CFR 183.200
33 CFR 159.71
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2023
Resolved 15 August 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 August 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to protect crew and the vessel from electrical hazards. Extension cord being used as permanent wiring in port engine room. Remove extension cord and replace with proper cable.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2022
Resolved 22 August 2022
Resolution: Extension cord has been removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 August 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to protect crew and the vessel from electrical hazards. Positive lead on motors for oil changeout pumps in both P/S engine rooms do not have terminal protection to prevent shorts. Install protection on positive terminal.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2022
Resolved 22 August 2022
Resolution: Rubber boot has been installed on both motors.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 August 2022
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew and the vessel from electrical hazards. Aft stbd spot light has broken mount and is being held up with zip ties. Replace mount or entire light.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2022
Resolved 22 August 2022
Resolution: Spotlight has been replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 15 August 2022
Resolved
A watertight door must be fitted with quick action closing devises operable from both sides of the door. Port engine room door bottom dog is broke. Replace.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2022
Resolved 22 August 2022
Resolution: Engine room dog has been replaced.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 9 June 2021
Resolved
Both port and starboard eng. room fwd fire dampers are not properly working. Must reapair or replace and prove proper operations.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2021
Resolved 9 June 2021
Resolution: Operation restored while inspection team aboard. Cause was a siezed pin.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 June 2021
Resolved
Railing on center bow is missing which is a safety hazard for crew. Must fix to like new conditon.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2021
Resolved 16 June 2021
Resolution: Safety net installed, permanent gates being made.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 June 2021
Resolved
Port engine room electrical distribution panel needs to be re-labeled.
Rectify prior to 7 days
Action required: 705 - Other - as specified
Due 16 June 2021
Resolved 16 June 2021
Resolution: Updated markings
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 9 June 2021
Resolved
Gen set exhaust on port side in laz space does not have lagging. Must replace.
Rectify prior to 7 days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 June 2021
Resolved 16 June 2021
Resolution: Lagging added to exhaust
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 June 2021
Resolved
CO2 bottles sit on metal plate, place a non-metallic barrier between bottle and place.
Rectify orior to 7 days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 June 2021
Resolved 16 June 2021
Resolution: Rubber placed between
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 June 2021
Resolved
Remove all electrical dead end wires, non-marine type power strips, daisy chain, ext cords from space below bridge.
Rectify prior to 7 days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 June 2021
Resolved 9 June 2021
Resolution: Rectified onboard to satisfaction of lead inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 June 2021
Resolved
Remove non-marine type power strips in snack bar.
Rectify prior to 7 days.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 June 2021
Resolved 16 June 2021
Resolution: Items removed
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 9 June 2021
Resolved
Electronic Chart display is not working. Must fix to navigate properly.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2021
Resolved 9 June 2021
Resolution: Rectified while onboard to the satisfaction of lead inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 9 June 2021
Resolved
Port Engine room has an exhaust leak casuing inspector's safety meter to alarm. Must find and fix to new conditon.
Rectify prior to seven days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 June 2021
Resolved 16 June 2021
Resolution: Leak found, part re-placed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 June 2021
Resolved
Vessel's crew and captain unfamiliar with safety systems due to vessel being laid-up up for 6 months, must conduct company training and document.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2021
Resolved 16 June 2021
Resolution: Company conducted additional traing and sent documents as proof.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 May 2020
Resolved
Fixed fire extinguishing systems must have controls and valves that automatically shutdown all engines that draw intake air from the protected space. The starboard generator was unable to shut down due to a the fuel shutdown solenoid. 46 CFR 181.410(b)
Rectify prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 June 2020
Resolution: Attending Marine Inspectors verified proper repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 May 2020
Resolved
A bilge suction must be fitted with a suitable strainer. The bilge suction in the starboard lazarette space is missing a strainer. 46 CFR 182.510(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 June 2020
Resolution: Attending Marine Inspectors verified proper repair.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 May 2020
Resolved
All wire connections must be made within a watertight enclosure. All bilge high level alarm connections are not in enclosures. 46 CFR 183.340(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 June 2020
Resolution: Attending Marine Inspectors verified proper repair.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 5 March 2020
Resolved
Repair cracked welds (01) on transverse bulkhead just forward of ladder in port side forepeak, (04) on next transverse bulkhead moving forward, all marked with yellow chalk. Inspect space for further cracked welds and repair as necessary.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2020
Resolved 17 April 2020
Resolution: Deficiency rectified with photo evidence/routine visits to boatyard during COVID-19.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 5 March 2020
Resolved
Repair forward bulkhead penetration for tank vent, port side. Penetration found with compromised welds on both sides of penetration in tank void and void forward.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2020
Resolved 17 April 2020
Resolution: Deficiency rectified with photo evidence/routine visits to boatyard during COVID-19.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 5 March 2020
Resolved
Repair forward bulkhead penetration for tank vent, stbd side. Penetration found with compromised welds on both sides of penetration in tank void and void forward.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2020
Resolved 17 April 2020
Resolution: Deficiency rectified with photo evidence/routine visits to boatyard during COVID-19.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 5 March 2020
Resolved
Repair cracked welds found on side shell (o/b), just above the main deck, fwd of the main engine- as marked
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2020
Resolved 17 April 2020
Resolution: Deficiency rectified with photo evidence/routine visits to boatyard during COVID-19.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 March 2020
Resolved
5--Replace/repair valves that have corroded on steering lines in port lazarette.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2020
Resolved 17 April 2020
Resolution: Deficiency rectified with photo evidence/routine visits to boatyard during COVID-19.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 5 March 2020
Resolved
Clean/preserve/protect strengthening plate for starboard strut in lazarette.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2020
Resolved 17 April 2020
Resolution: Deficiency rectified with photo evidence/routine visits to boatyard during COVID-19.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 5 March 2020
Resolved
Repair port rub rail sharp inset found around midships of vessel.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2020
Resolved 17 April 2020
Resolution: Deficiency rectified with photo evidence/routine visits to boatyard during COVID-19.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 5 March 2020
Resolved
Repair rub rail on port quarter of vessel, cracked welds and strengthening members tripped.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2020
Resolved 17 April 2020
Resolution: Deficiency rectified with photo evidence/routine visits to boatyard during COVID-19.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 5 March 2020
Resolved
During cleaning and coating of fuel tanks, yard representative discovered further pitting in fuel tanks of vessel forcing further hull material to be cut from fuel tanks on both port and starboard side. Vessel is catamarran hull type with integral fuel tanks in number three void from bow.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2020
Resolved 17 April 2020
Resolution: Deficiency rectified with photo evidence/routine visits to boatyard during COVID-19.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 5 March 2020
Resolved
Discovered hole in hull plating just aft of port side fuel tank in machinery space approximately six to eight inches aft of forward bulkhead.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2020
Resolved 17 April 2020
Resolution: Deficiency rectified with photo evidence/routine visits to boatyard during COVID-19.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 May 2019
Resolved
Vessel must prove proper operation of FF system after all repairs are done and also the CGMI must witness a pressure test of all new piping. Vessel will place an extra crew member on board as a fire watch, conduct rounds of both engine rooms every 15 min, and log in the official log book. This is only good in the New York zone for 2 weeks.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2019
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 6 May 2019
Resolved
Due to vessel's new exhaust system the CO2 piping has been altered from the approved drawing and the heat actuator is now located dangerously close to the exhaust muffler; vessel must submit drawing of changes with list of materials used, re-test piping system to correct psi, add a winter green odorizing unit, and heat actuator moved to a new location.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2019
Resolved 23 May 2019
Resolution: Vessel tested piping with CGMI and 3rd party fire service company.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 6 May 2019
Resolved
All thee IBA's are improperly rigged to the vessel via the painter preventing from floating free, must correct this by attaching to the weak link as provided and required by regulation and manufacture instructions.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2019
Resolution: Vessel Captain corrected on the spot and training with crew was conducted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2019
Resolved
Vessel has a live dead end wire in the port engine room that possible broke off a breaker/junction box; secure source of power and fix to a safe approved condition
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2019
Resolution: Wire re-=connected to terminal.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 May 2019
Resolved
The vessel's bilge system did not de-water the compartment in a timely manner (VERY SLOW) must prove proper operation per the regulation. (50GPM)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2019
Resolution: Vessel installed new in kind fire/bilge pump and tested with CGMI.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 6 May 2019
Resolved
Vessel's port engine room power ventilation is not on-board due to it being broke and a new one is being installed which affects the fixed fire fighting shut downs, must replace to original approval and demonstrate proper operation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2019
Resolution: Installed new vent fan. All test sat.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 6 May 2019
Resolved
During this inspection the Captain & crew were unfamiliar with the life saving arrangements, the Capt did not know how to operate the fixed fire system when asked by the CGMI; this is due to the crews and captains changing vessels/platforms. The company must provide documented proof on vessel specific training provided to the Capt and crew for the Ocean State.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 May 2019
Resolution: Captain and crew were re-trained IAW company's volunteer SMS and documented on correct forms.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2019
Resolved
A light cover in the stbd aft engine room is missing causing a personnel safety issue, must place a protective cover over the light as discussed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 May 2019
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 2 October 2018
Resolved
Vsl is broadcasting invalid MMSI, Vsl is broadcasting invalid IMO #, Vsl is broadcasting Invalid Call Sign and Vsl is not broadcasting static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 15 August 2022
Resolution: Cleared by activity #7504377.
Construction/Loadline › Hull › Side Shell
Issued 18 June 2017
Resolved
STARBOARD HULL STEM SIDESHELL/CONNECTION, FRACTURED AT WELDMENT MULTIPLE LOCATIONS, STEM DEFLECTED. CROP RENEW IN KIND TO SAT OF COG OCMI.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 June 2017
Resolved 5 July 2017
Resolution: Repairs are complete to the satisfaction of the COG OCMI.
Construction/Loadline › Structures › End Bulkhead
Issued 18 June 2017
Resolved
STEM APRON PLATE MISSING THREADED PLUGS ALLOWS INGRESS OF WATER TO FOREPEAK.
Action required: 60 - Rectify deficiencies prior to movement
Due 18 June 2017
Resolved 18 June 2017
Resolution: PLUGGED WITH STAINLESS BOLTS
Construction/Loadline › Structures › Deck Plating
Issued 18 June 2017
Resolved
DECK SOFT PATCH IWO E/R EVIDENCE OF SALTWATER INGRESS OUTBOARD FLANGE, CRYSTALIZED SALT CAKED/DRIPPING FROM EDGE ON TO WIRING ETC...ID SOURCE OF WATER INGRESS, SEAL TO SAT OF ATTENDING MI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 June 2017
Resolved 5 July 2017
Resolution: Repairs complete to the satisfaction of the attending MI.
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 18 June 2017
Resolved
WIRING PORT LAZARETTE NOT PROPERLY DEAD ENDED, REMOVE OR REPAIR LOOSE/UNSECURED CABLE, COVER OPEN JUNCTION BOX.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 June 2017
Resolved 5 July 2017
Resolution: Repairs are complete to the satisfaction of the attending MI.
Electrical › Lighting (service) › Lighting Fixture
Issued 18 June 2017
Resolved
MASTHEAD LIGHT IMPROPERLY PLACED AND WIRED ON WRONG CIRCUIT, ENERGIZES ON ANCHORLIGHT CIRCUIT. ANCHOR LIGHT IMPROPERLY PLACED/NOT OPERATIONAL, DOES NOT ENERGIZE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 June 2017
Resolved 5 July 2017
Resolution: Repairs are complete to the satisfaction of the attending MI.
Documentation › Certificates/Documents › FCC SSL
Issued 5 June 2017
Resolved
Vessel's master must provide a valid FCC Marine Operator Permit.
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 16 June 2017
Resolution: Marine Radio Operator Permit obtained.
Communications › Radio Communications › EPIRB
Issued 5 June 2017
Resolved
EPIRB's NOAA registration has it listed as a Category 2 EPIRB instead of as a Category 1. Registration needs to be updated.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 16 June 2017
Resolution: Registration has been updated.
Engineering › Bilge Water Management System › Valve
Issued 5 June 2017
Resolved
The bilge suctions in both fore peaks were not operational upon initial testing. Both check valves had to be knocked loose with a hammer. The vessel's operator much prove proper operation of the bilge suction for all compartments and provide a signed letter from the port engineer that the system is fully operational.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 16 June 2017
Resolution: Port Engineer testified to all valves working properly. New check valves were installed on all bilge suctions.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 5 June 2017
Resolved
Fix cracks in railings up at the bow.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 28 June 2017
Resolution: MI verified railing has been fixed
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 5 June 2017
Resolved
Children’s PFDs on the upper deck need to be stored separate from the adult life jackets.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 11 July 2017
Resolution: Children PFDs located in locker on upper deck were in excess of what was required by the COI so they have been removed from the vessel.
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 June 2017
Resolved
The audible noise on the STBD side fuel compartment bilge alarm and the light on the port side Bow #2 space bilge alarm are inoperable.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 16 June 2017
Resolution: Bilge alarms operating properly.
Lifesaving › Lifefloat › Serviceable
Issued 5 June 2017
Resolved
Repair or replace all 5 life floats. Vessel to submit proposal for any repairs prior to commencing. Vessel is restricted from operating no more than 3 NM from shore from 31MAY-01NOV.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 November 2017
Resolved 11 July 2017
Resolution: New IBAs have been installed onboard and weight calcs exmained by MSC.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 5 June 2017
Resolved
Properly mount loose fire extinguishers in engine rooms.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 16 June 2017
Resolution: New mounts have been installed.
Fire Fighting › Fire Pumps › Pressure
Issued 5 June 2017
Resolved
Fix/replace both pressure gages on the fire mains in both engine rooms and verify proper operating pressure
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 16 June 2017
Resolution: New presure gages installed.
Electrical › Electrical Distribution System (service) › Cable
Issued 5 June 2017
Resolved
Remove solid core cable from battery charger room and replace with proper stranded cable.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 June 2017
Resolved 18 June 2017
Resolution: Cable has been removed
Electrical › Electric Supply System (service) › Battery Charger
Issued 5 June 2017
Resolved
Provide ammeter in the battery charger circuit.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 October 2017
Resolved 14 June 2018
Engineering › Diesel Engine (propulsion-electric) › Emergency shutdown
Issued 2 March 2017
Resolved
Loss of propulsion not ID'd; conduct sea trials and test MDEs and gens.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 March 2017
Resolution: Operator accidently triped a switch to a control panel. Vessel ordered a guard for the switch.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 28 June 2016
Resolved
7 water light batteries are expired. Replace batteries. Vessel restricted to day light operations.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 June 2016
Resolved 29 June 2016
Resolution: Vessel replaced batteries.
Lifesaving › Lifefloat › Paddle
Issued 28 June 2016
Resolved
Lifefloat missing paddles. Provide two paddles for life float.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 June 2016
Resolved 29 June 2016
Resolution: Vessel replaced paddles.