MAURY USCG vessel records Sign in
← All vessels

TORM GERD

TORM GERD is a 2002 tank ship. The Coast Guard has recorded 25 inspections since 2003, most recently in February 2020, along with 8 deficiencies and 7 operational controls.

Records from 2003 to 2020. Most recent: operational control imposed, 19 February 2020.

Built
2002
Last inspected
19 February 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9240897 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V3898
626716
Flag
SINGAPORE
—
Maury page id
psix-626716

Inspections, by type

…with no type recorded8
Years with a record 12 calendar years (2003–2020)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it11742 - Convention (Subpart B), Net Ton
45960 - Dead Weight, Metric Ton
55839 - Displacement, Metric Ton
30128 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ABBEY K Towing Vessel · MISLE 102794 · 21 September 2004 · activity 2202307

Inspection history · 25

19 February 2020 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6911958
14 February 2020 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6909484
13 February 2020 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6908818
12 December 2019 COC-CHEM & TVE Annual · ISPS II Exam · Administrative Inspection · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6867660
6 March 2019 COE-Administrative
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6637475
17 January 2019 Deficiency Check · COE-Administrative
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6610991
12 December 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6596259
12 December 2018 COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6596306
13 January 2017 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6070561
4 December 2016 COE-Dockside · ISPS II Exam · Ballast Water Examination · COC-CHEM Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6049819
29 July 2016 ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5952471
1 January 2016 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5789580
27 October 2015 ISPS II Exam · COC-CHEM & TVE Renew · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5746941
4 May 2012 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4302349
2 July 2011 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4046633
7 May 2008 Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3200667
7 May 2008 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3201361
18 April 2008 COC-CHEM Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3186874
14 July 2005 COC-TVE Renew · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2426359
15 October 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2221441
21 September 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2202307
18 August 2004 NPV Safety Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2169934
26 July 2004 COC-CHEM Annual · ISPS II Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2145236
19 February 2004 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2011717
10 June 2003 Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1814889

Deficiency record · 8

08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 12 December 2018 Resolved
No. 1 code: 1099 Cite: 46CFR39.2007C(1) Action Taken: 15ac High level alarm must activate when cargo reaches 95% or higher but before tank overfill alarm activates. High level alarms for cargo tanks 1s, 2s, 3s, and 2p did not activate prior to overfill alarm sounding. Rectify deficiency prior to loading cargo.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 12 December 2018
Resolved 17 January 2019
Resolution: Verified Classification report attesting to the proper operation of the High-Level alarms for 1S, 2S, 3S, 2P Tanks. Ref: Class Report attached to activity: 6610991
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 12 December 2018 Resolved
Port anchor is damaged and missing a fluke - requires replacement.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 January 2019
Resolved 17 January 2019
Resolution: Verified Classification report attesting to the replacement of Port Anchor damaged in NY during the month of December 2018 at anchorage. Ref: Class Report attached to Act:6610991
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 27 October 2015 Resolved
PSCO OBSERVED MULTIPLE PIN HOLE SOFT PATCHES IN IGG LINE AS WELL AS MULTIPLE LEAKS ON COMBUSTION CHAMBER AND SCRUBBER AND THE SALT WATER COOLING LINE. SOLAS04 I-II(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 October 2015
Resolved 29 October 2015
Resolution: RECIEVED CLASS REPORT ATTESTING TO THE PROPER REPAIR AND OPERATION OF THE IGG PIPING.
Electrical › Electric Supply System (service) › Cable
Issued 27 October 2015 Resolved
PSCO OBSERVED DEAD END WIRES IN ENGINE ROOM, LOCATION WAS ON THE DECK ABOVE THE BLOWERS. SOLAS II-1 45/1.3
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 October 2015
Resolution: RECIEVED CLASS REPORT ATTESTING TO REPAIRS.
Engineering › Sea-water System (primary cooling) › Piping
Issued 27 October 2015 Resolved
PSCO OBSERVED THE CASCADE DRAIN PIPING IN MULTIPLE PLACES WASTED, WITH ONE SECTION HAVING A RUBBER SOFT PATCH. SOLAS04 II-I 45/1.3
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 January 2016
Resolution: MSU Texas City has received DNV-GL class report attesting to the proper and permanent repairs to the vessels cascade drain piping.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 18 April 2008 Resolved
The vessel ODME is inoperable due to a faulty flow switch and transmitter. MARPOL 73/78 (Cons 2006) Annex 1 Reg. 31.2
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 April 2008
Resolved 30 August 2009
Resolution: DNV class report # 23462 dated 6/12/08
Deck/Cargo › Vapor Control Systems › Blower
Issued 26 July 2004 Resolved
PRIOR TO NEXT US PORT PROVIDE CLASS RPT ATTESTING TO PROPER OPS OF IG BLOWERS OR SUFFICIENT SPARE PARTS FOR ONE BLOWER. SOLAS II-2 REG 62.7.1
Action required: 705 - Other - as specified
Resolved 18 August 2004
Resolution: Received DNV report clearing item.
Deck/Cargo › Vapor Control Systems › Inerting System
Issued 26 July 2004 Resolved
PRIOR TO NEXT US PORT PROVIDE CLASS RPT ATTESTING TO THE CONTENTS OF THE CALIBRATION GAS FOR THE IG 02 ANALYZER. SOLAS II-2 REG 62.18
Action required: 705 - Other - as specified
Resolved 18 August 2004
Resolution: Received DNV report clearing item.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.