JAMES M HEWGLEY

JAMES M HEWGLEY is a 2003 towing vessel. The Coast Guard has recorded 12 inspections since 2004, most recently in September 2025, along with 26 deficiencies.

Records from 2004 to 2025. Most recent: inspection, 17 September 2025.

Built
2003
Last inspected
17 September 2025
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDJ4566
626734
Flag
UNITED STATES
Maury page id
psix-626734

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspections, by type

…with no type recorded1
Years with a record 9 calendar years (2004–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)51.0 ft × 22.0 ft × 8.0 ft
Registered tonnagegross 75 / net 60
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderVERRET SHIPYARD INC · PLAQUEMINE · built 2003
Hull materialSteel
PropulsionDiesel Direct
Hull shapeBox
Hull configurationMonohull
Hailing portPORT OF CATOOSA, OK
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it60 - Simplified, Net Ton
75 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 12

17 September 2025 COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8213186
11 November 2024 Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8033430
19 September 2024 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 8004845
23 August 2023 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7774386
21 September 2022 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7563126
1 April 2022 Annual Inspection
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 7422230
30 June 2020 Administrative Inspection · Deficiency Check · MTSA Verification · Initial Certification
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6984701
19 June 2020 Administrative Inspection
Administrative · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6981352
25 July 2018 Administrative Inspection
Administrative · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 6490555
29 January 2017 Type not recorded
No type recorded · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 6083945
8 December 2010 Industry Initiated Exam · MTSA Verification
Physical examination · Marine Safety Detachment Ft. Smith · USCG Heartland District (CGD-H) · Activity 3910261
30 January 2004 Security Plan Review - ASP
Administrative · Commandant (CG-FAC) · Activity 2000442

Deficiency record · 26

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 19 September 2024 Resolved
Each towing vessel must be equipped with gauges at the machinery location for auxiliary generators to include an RPM gauge. The vessel did not have an RPM gauge at the machinery location. RPM gauge must be fitted at the machinery station.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2024
Resolved 11 November 2024
Resolution: Vessel installed new RPM gauge on the generators.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 September 2024 Resolved
Electrical equipment and electrical cables must be suitable protected from we and corrosive environments. The vessels battery installations were not protected and were exposed to the environment in the engine room and the dog house under the bridge of the vessel. The vessel must install battery boxes to properly protect the installations and cables associated with them.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 October 2024
Resolved 11 November 2024
Resolution: Batteries were placed inside a battery box providing proper protection.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 23 August 2023 Resolved
Machinery alarms were not available for the vessel's generator (low lube oil pressure & high water temp) and steering system (low hydraulic fluid level).
Action required: 705 - Other - as specified
Due 23 October 2023
Resolved 31 October 2023
Resolution: Alarms installed at the operating station (visual/audible) that monitor low lube oil pressure and high water temperature on the generator and hydraulic oil low level on steering system in addition to existing alarms.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 23 August 2023 Resolved
Records were not available indicating that all portable fire extinguishers were annually inspected.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2023
Resolved 31 August 2023
Resolution: Email provided with pictures showing the portable fire extinguishers (via label) were annually tested.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 September 2022 Resolved
Of the vessel's 02 lifebuoys; only 01 had a floating electric light with the other needing one installed.
Action required: 705 - Other - as specified
Due 28 September 2022
Resolved 26 September 2022
Resolution: a light was installed on the remaining lifebuoy and a picture was emailed to MSD FT. Smith.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 September 2022 Resolved
Pressure relief valve on the air receiver was not tested twice every 5 years with no more than 3 years between tests.
Action required: 705 - Other - as specified
Due 28 September 2022
Resolved 26 September 2022
Resolution: A new pressure relief valve for the air receiver was installed, pictures of installation were sent via email to MSD Ft. Smith.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 1 April 2022 Resolved
General alarm indicating light in the engine room was located in the forward bulkhead on the starboard corner and was found to not be of adequate flash intensity to alert a crewmember working within the space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2022
Resolved 13 April 2022
Resolution: Vessel Manager sent photo and video of the General alarm light in the engine room functioning.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 30 June 2020 Resolved
The following list of items must be recorded in the TVR, official logbook, or in accordance with the TSMS applicable to the vessel: (1) Personnel records, in accordance with §140.400; (specifically who is filling positions)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2020
Resolved 21 July 2020
Resolution: Recieved email from vessel representative with implemented personnel records.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 30 June 2020 Resolved
The following list of items must be recorded in the TVR, official logbook, or in accordance with the TSMS applicable to the vessel: (3) Record of drills and instruction, in accordance with §140.420; (Fire, abandon ship and man overboard functional drills)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2020
Resolved 21 July 2020
Resolution: Received email with record of drills.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 30 June 2020 Resolved
The following list of items must be recorded in the TVR, official logbook, or in accordance with the TSMS applicable to the vessel: (6) Navigation assessment, in accordance with §140.635;
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2020
Resolved 21 July 2020
Resolution: Recieved email with navigation assesment form implemented on vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 June 2020 Resolved
Life jacket marking, lights and whistle missing
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2020
Resolved 16 July 2020
Resolution: Company properly marked and outfitted lifejackets.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 30 June 2020 Resolved
Vessel has a radar exemption letter that prohibits night time operations, however vessel was operating at night. Request new radar exemption with night operation provision or cease night time operation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 July 2020
Resolution: Vessel ceased night operations and requested a new exemption to continue night operations.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 30 June 2020 Resolved
Post Emergency Duties List on Bridge
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2020
Resolved 3 August 2020
Resolution: Emergency Duties List posted.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 30 June 2020 Resolved
Conduct Drills with new crew-members within 24 hours
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 July 2020
Resolution: Recieved email evidence that company conducted drills with new crew members and implemented policy to conduct trainng within 24 hours.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 30 June 2020 Resolved
Provdie Fall Overboard Prevention Policy
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 July 2020
Resolution: Recieved policy via email.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 30 June 2020 Resolved
Replace Alcohol Testing strips
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2020
Resolved 16 July 2020
Resolution: Company replaced alcohol test strips.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 30 June 2020 Resolved
[name withheld] rings with vessel name, attach lights and lifeline around body of the lifering
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 July 2020
Resolution: Liferings were properly marked and lights attached properly.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 30 June 2020 Resolved
Provide hotwork policy IAW NFPA 306 on board
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 July 2020
Resolution: Recieved policy via email.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 June 2020 Resolved
Relocate fire extinguisher in engine room and galley near exits permanently mounted with proper bracket
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2020
Resolved 3 August 2020
Resolution: Extenguishers relocated with proper brackets.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 30 June 2020 Resolved
Post Oil Placard
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2020
Resolved 3 August 2020
Resolution: Oil Placard Posted.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 30 June 2020 Resolved
Post Garbage Placard
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2020
Resolved 3 August 2020
Resolution: Garbage placard posted.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 30 June 2020 Resolved
Provide Health and Safety Manual
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 July 2020
Resolution: Recieved policy via email.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 30 June 2020 Resolved
Post fuel shut off instructions and make available for use without tools
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2020
Resolved 15 July 2020
Resolution: Fuel shutoff instructions posted.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 June 2020 Resolved
Remove dead end wires on Starboard main diesel engine
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2020
Resolved 16 July 2020
Resolution: Company removed dead end wire from vessel.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 June 2020 Resolved
Install metal cable hanger supports with chaffing protection every 48 inches in battery room below the wheelhouse
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2020
Resolved 3 August 2020
Resolution: Recieved pictures via email that Cable hangers were installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 June 2020 Resolved
All owners & operators of an existing towing vessel must have a valid COI prior to the specified phase-in period. This vessel is on of the 25% of the vessels that has not obtained a valid COI. The vessel shall be made available for a Coast Guard COI inspection within 90 days*. If an inspection is not completed prior to this date, the action for this deficiency shall be changes to a CODE 60(Rectify deficiencies prior to movement) and the vessel may no longer be permitted to operate.
Action required: 705 - Other - as specified
Due 2 September 2020
Resolved 3 September 2020

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.