Records from 1985 to 2013. Most recent: casualty investigation, 18 November 2013.
Inspection history · 45
23 March 2009
Type not recorded
No type recorded · USCGC ANACAPA (WPB 1335) · USCG Northwest District (CGD-NW) · Activity 3447588
25 September 2008
Type not recorded
No type recorded · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 3332650
23 May 2005
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2366380
2 August 2003
Administrative Inspection
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1897952
20 November 2002
Annual Inspection · Re-Inspection · Plan Review "T" Boat
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 1708970
13 August 2002
Hull Examination · Plan Review "T" Boat · Examination of Repairs
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 1660938
7 June 2001
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1373508
1 June 2001
Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1370185
18 July 2000
COI Inspection · Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1413763
24 January 2000
Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 816201
20 December 1999
Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1399253
28 June 1999
Deficiency Check · Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1365276
8 December 1998
Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1368955
17 November 1997
COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1378279
10 November 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 784527
10 July 1997
Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1430428
2 July 1996
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1088875
24 May 1996
Re-Inspection · Hull Examination · MARPOL Annex V Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1355823
16 June 1995
Examination of Repairs · Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 878358
12 June 1995
Deficiency Check · Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1431538
26 April 1995
Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1380225
16 June 1994
COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1374076
21 April 1994
Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1358642
12 October 1993
Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 830494
12 October 1993
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1142047
4 June 1993
Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 826560
22 April 1993
Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 836717
30 March 1993
Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1370570
8 December 1992
Drydock Extension
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 826216
14 July 1992
Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1359451
29 June 1991
COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 826558
29 June 1991
COI Inspection · Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 942101
9 August 1989
Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1343215
19 May 1988
COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1042980
3 May 1988
Hull Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1350989
14 March 1988
Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1029428
16 February 1988
Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1021105
30 June 1987
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1021237
29 June 1987
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1327573
5 June 1987
Hull Examination · Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1325646
25 November 1986
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1019810
23 June 1986
Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1304345
25 March 1986
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1306133
13 June 1985
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 994652
6 May 1985
COI Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1291705
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 20 November 2002
Resolved
Post original Certificate of Documentation on vessel.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2014
Resolution: vessel operating as a 6 pack
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 20 November 2002
Resolved
Show proof of vessel compliance with Drug and Alcohol testing requirements. LEGACY COMPONENT DESC: Recordkeeping
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2014
Resolution: vessel operating as a 6 pack
Lifesaving › Liferaft Equipment › Bailer
Issued 20 November 2002
Resolved
Service Life Raft LEGACY COMPONENT DESC: Liferaft Servicing
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2014
Resolution: vessel operating as a 6 pack
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 20 November 2002
Resolved
Replace CARDOX general purpose storage bottle with a WALTER KIDDEE 75lb. CO2 bottle in accordance with the previously approved installation plans. LEGACY COMPONENT DESC: Tanks
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2014
Resolution: vessel operating as a 6 pack
Personnel › Certificates/Documents/Licenses › License, Mate
Issued 20 November 2002
Resolved
Vessel is not to conduct operations with passengers onboard for more than 12 hours in a 24 hour period unless in compliance with Certificate of Inspection. Show proof of adequate manning for control of vessel with at least one Licensed Master and one Licensed Mate.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2014
Resolution: vessel operating as a 6 pack
Documentation › Logs/Records › Logbook (official)
Issued 20 November 2002
Resolved
Show proof of conducting required training and provide a training log book that meets the requirements of 46CFR185.420.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2014
Resolution: vessel operating as a 6 pack
Documentation › Logs/Records › Logbook (official)
Issued 20 November 2002
Resolved
Provide lifesaving equipment maintenance records that meet the requirements of 46CFR185.702 LEGACY COMPONENT DESC: Logbook (official)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2014
Resolution: vessel operating as a 6 pack
Documentation › Logs/Records › Logbook (official)
Issued 20 November 2002
Resolved
Provide a voyage plan that meets the requirements of 46CFR185.503 when carrying passenger overnight.
Action required: 705 - Other - as specified
Resolved 5 November 2014
Resolution: vessel operating as a 6 pack
Documentation › Logs/Records › Logbook (official)
Issued 20 November 2002
Resolved
Provide a passenger count in accordance with 46CFR185.504 when a voyage plan is not required.
Action required: 705 - Other - as specified
Resolved 5 November 2014
Resolution: vessel operating as a 6 pack
Communications › Audible Communications › Bell
Issued 20 November 2002
Resolved
Provide a 200mm (8 inch) bell in accordance with the Inland Navigation Rules
Action required: 705 - Other - as specified
Resolved 5 November 2014
Resolution: vessel operating as a 6 pack
Communications › Audible Communications › Horn/Whistle
Issued 20 November 2002
Resolved
Provide a horn/whistle that meets the requirements of the Inland Navigation Rules.
Action required: 705 - Other - as specified
Resolved 5 November 2014
Resolution: vessel operating as a 6 pack
Communications › Visual Communication › Red Warning Signal
Issued 20 November 2002
Resolved
Provide a brightly colored, portable, water tight container for the flares and smoke signals marked "Distress Signals" LEGACY COMPONENT DESC: Distress Signal Storage
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 5 November 2014
Resolution: vessel operating as a 6 pack
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 20 November 2002
Resolved
Provide a 39.5 inch high railing in accordance with "new" Subchapter T 46CFR177.900(d)(1) or as alternative the vessel may install a 42 inch rail in accordance with "old" Subchapter T 46CFR177.35-1(c). Presently the rails forward measure 34" and aft 36" in height.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 5 November 2014
Documentation › Manifests/Lists › Dangerous Goods Manifest/Stowage Plan
Issued 20 November 2002
Resolved
Provide a procedure where a Crew and Passenger list are transmitted to a shoreside facility or representative when the vessel carries passengers overnight in accordance with 46CFR185.502. LEGACY COMPONENT DESC: Passenger List
Action required: 705 - Other - as specified
Resolved 5 November 2014
Resolution: vessel operating as a 6 pack
Lifesaving › Liferaft Equipment › Anti-seasickness Medicine
Issued 20 November 2002
Resolved
Provide a Survival craft placard that meets the requirements of 46CFR185.518. LEGACY COMPONENT DESC: Life raft placard
Action required: 705 - Other - as specified
Resolved 5 November 2014
Resolution: vessel operating as a 6 pack
Communications › Alarms/Indicators › Bilge Alarm
Issued 20 November 2002
Resolved
Prove proper operation of the bilge high level alarm for the forepeak.
Action required: 705 - Other - as specified
Resolved 5 November 2014
Resolution: vessel operating as a 6 pack
Electrical › Electrical Distribution System (service) › Bus Bar Connection
Issued 20 November 2002
Resolved
Remove the orange extension cord that is installed behind the bulkheads and in the closet in the forward passenger berthing area. LEGACY COMPONENT DESC: Wiring
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 5 November 2014
Resolution: vessel is operating as a 6 pack
Personnel › Certificates/Documents/Licenses › FV Safety Instructor
Issued 20 November 2002
Resolved
Provide a FCC Marine Radio Operator Permit for all vessel masters. Vessel is limited to operation not more than 1000 yards from land if the Master does not have the required license in accordance with USCG memorandum of understanding with FCC. LEGACY COMPONENT DESC: License, Operator
Action required: 705 - Other - as specified
Resolved 5 November 2014
Resolution: vessel is operating as a 6 pack
Engineering › Bilge Water Management System › Eductor
Issued 20 November 2002
Resolved
On the Achilles Rigid Hull Inflatable; repair the cracked transom and replace the oversized (15hp) outboard motor with one than is not more than 9.9 hp in accordance with manufacturer's data placard. Skiff may not be used to carry passengers until repaired and an appropriate engine is installed. LEGACY COMPONENT DESC: Skiff/Vessel Tender
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 5 November 2014
Resolution: vessel is operating as a 6 pack
Communications › Radio Communications › EPIRB
Issued 20 November 2002
Resolved
Replace the expired Hydrostatic Release for the EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2014
Resolution: vessel is operating as a 6 pack
Construction/Loadline › Hull
Issued 19 August 2002
Resolved
Crop and renew six hull frames identified on port side in fore peak due to extensive rot at frame ends. LEGACY COMPONENT DESC: Hull Frame
Action required: 705 - Other - as specified
Due 19 August 2002
Resolved 1 October 2002
Resolution: New frames installed
Construction/Loadline › Hull
Issued 19 August 2002
Resolved
Crop and renew Breasthook due to fractures LEGACY COMPONENT DESC: Breasthook
Action required: 705 - Other - as specified
Due 1 October 2002
Resolved 1 October 2002
Resolution: New breasthook installed
Construction/Loadline › Hull
Issued 19 August 2002
Resolved
Crop and renew three hull planks at wind and water line, port side aft, where holed due to rot. Each plank end/butt joint must off set the other by a minimum of three frame bays. LEGACY COMPONENT DESC: Hull Plating
Action required: 705 - Other - as specified
Due 19 August 2002
Resolved 1 October 2002
Resolution: Hull planks replaced
Construction/Loadline › Hull › Hull Plating
Issued 19 August 2002
Resolved
Crop and renew transverse frame at shear on transom due to rot, excessive checking, and cracks across grain. LEGACY COMPONENT DESC: Transverse Frame
Action required: 705 - Other - as specified
Resolved 5 November 2014
Resolution: vesel operating as a 6 pack
Construction/Loadline › Hull › Hull Plating
Issued 19 August 2002
Resolved
Crop and renew aft port Knee in way of transom at the shear strake due to mechanical damage and fractures associated with transverse frame in item #5. LEGACY COMPONENT DESC: Knee
Action required: 705 - Other - as specified
Resolved 5 November 2014
Resolution: vessel operating as a 6 pack
Construction/Loadline › Hull
Issued 19 August 2002
Resolved
Renew caulking at Garboard Strake and Keel, Transom, and other places as identified. LEGACY COMPONENT DESC: Caulking
Action required: 705 - Other - as specified
Due 19 August 2002
Resolved 1 October 2002
Resolution: Affected areas recaulked
Construction/Loadline › Hull
Issued 19 August 2002
Resolved
Scrape away mold growth on frames in lazerette, treat/preserve, and renew as necessary. LEGACY COMPONENT DESC: Framing, general
Action required: 705 - Other - as specified
Due 19 August 2002
Resolved 1 October 2002
Resolution: Corrected
Construction/Loadline › Hull
Issued 19 August 2002
Resolved
Crop and renew hull plank in way of bilge system overboard discharge due to "[name withheld]" from stray current corrosion which has holed the planking LEGACY COMPONENT DESC: Hull Planking
Action required: 705 - Other - as specified
Due 19 August 2002
Resolved 1 October 2002
Resolution: New plank installed
Construction/Loadline › Hull
Issued 19 August 2002
Resolved
Make repairs to main deck aft, where water tight integrity has been compromised and allowing water to start to deteriorate underlayment and frames. LEGACY COMPONENT DESC: Decking
Action required: 705 - Other - as specified
Due 19 August 2002
Resolved 13 November 2002
Resolution: Refastened and and recaulked
Construction/Loadline › Hull
Issued 16 August 2002
Resolved
Crop and renew six transverse deck frames in fore peak due to extensive rot on frame ends. LEGACY COMPONENT DESC: Transverse Frame
Action required: 705 - Other - as specified
Due 16 August 2002
Resolved 1 October 2002
Resolution: New frames installed
Electrical › Electrical Distribution System (service)
Issued 13 August 2002
Resolved
Remove gang plug installed in cabinet with VCR which has been cut and improperly spliced. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 August 2002
Resolved 1 October 2002
Resolution: Removed
Electrical › Electrical Distribution System (service)
Issued 13 August 2002
Resolved
Remove equipment ground for 32v DC motor to bilge system from copper pipe and provide proper common ground.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 August 2002
Resolved 1 October 2002
Resolution: Equipment case ground now grounded to engine frame
Electrical › Electrical Distribution System (service)
Issued 13 August 2002
Resolved
Remove equipment wiring from direct connection at batteries and connect to proper distribution panel. LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 August 2002
Resolved 1 October 2002
Resolution: Excess unused wire removed and equipment no is directly connected to the batteries with exception of equipment associated with item 18 which is being moved to main distribution panel.
Electrical › Electric Generation Source (service)
Issued 13 August 2002
Resolved
Clean and service battery terminals with dielectric grease due to severe corrosion. LEGACY COMPONENT DESC: Battery terminals
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 August 2002
Resolved 1 October 2002
Resolution: Serviced
Electrical › Electrical Distribution System (service)
Issued 13 August 2002
Resolved
Remove improper wiring on TACO Circulation Pump - extension cord with end cut off, wired to controller, and plugged into outlet. Provide proper power supply though distribution system panel board and circuit with adequate breaker for load. Provide plans for evaluation/approval of this system. LEGACY COMPONENT DESC: Wiring
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 September 2002
Resolved 1 October 2002
Resolution: Rewired properly
Electrical › Electrical Distribution System (service)
Issued 13 August 2002
Resolved
Remove improper refrigerator wiring plugged into outlet in engine room, run through overhead to main deck. Provide proper power supply though distribution system panel board and circuit with adequate breaker for load. LEGACY COMPONENT DESC: Wiring
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 September 2002
Resolved 1 October 2002
Resolution: Rewired curcuit properly
Electrical › Electrical Distribution System (service)
Issued 13 August 2002
Resolved
Provide metal retention straps for electrical service wiring that is draped over steering cable on port side of engine room. Inspect wiring for chaffing, replace as necessary. LEGACY COMPONENT DESC: Wiring
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 September 2002
Resolved 1 October 2002
Resolution: Straps installed in way of rotating machinery in accordance with ABYC.
Electrical › Electrical Distribution System (service)
Issued 13 August 2002
Resolved
Remove small panel board from direct connection to battery distribution switch in engine room. Provide proper power supply though DC distribution system panel board and circuit with adequate breaker for loads. LEGACY COMPONENT DESC: Panelboard
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 September 2002
Resolved 1 October 2002
Resolution: Rewired curcuit properly
Electrical › Electrical Distribution System (service)
Issued 13 August 2002
Resolved
For wiring in closets in lower accommodations; tape splices made with twist type household wire nuts and place in closed junction boxes. LEGACY COMPONENT DESC: Junction Box
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 August 2002
Resolved 1 October 2002
Resolution: Proper connections made
Electrical › Lighting (service)
Issued 13 August 2002
Resolved
Remove improper household lamp cord used to supply power to lighting circuit in lower accommodations, rewire using boat cable. LEGACY COMPONENT DESC: Conductor
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 19 August 2002
Resolved 1 October 2002
Resolution: Lamp cord replaced with 14AWG boat cable.
Documentation
Issued 7 June 2001
Resolved
PROVIDE EVIDENCE OF MONTH IN WHICH LIFERAFT WAS SERVICED IN 2001.
Condition: Unknown
Due 5 July 2001
Resolved 5 July 2001
Documentation
Issued 7 June 2001
Resolved
PROVIDE EVIDENCE OF AN FCC MARINE RADIO OPERATOR'S PERMIT FOR A CURRENT CREWMEMBER. POSTED PERMIT WAS FOR A PREVIOUS MASTER WHO IS NO LONGER WITH_x001C_ THE VESSEL.
Condition: Unknown
Due 6 July 2001
Resolved 6 July 2001
Construction/Loadline
Issued 18 July 2000
Resolved
REPLACE GASKET ON FOUR PORTLIGHTS BELOW WEATHER DECK SO AS TO PROVIDE A FULLY WATERTIGHT SEAL.
Condition: Unknown
Due 20 November 2000
Resolved 17 November 2000
Fire Fighting
Issued 20 December 1999
Resolved
Provide three 2.5 gal capacity fire buckets with "fire bucket" stencil and lanyard as per 46CFR 181.610.
Condition: Unknown
Due 20 December 1999
Resolved 20 December 1999
Lifesaving
Issued 20 December 1999
Resolved
Remove all unserviceable ringbuoys from vessel.
Condition: Unknown
Due 20 December 1999
Resolved 20 December 1999
Accommodation/Occupational Safety
Issued 20 December 1999
Resolved
Provide safety chain/line, or equivalent, to close gap in aft rail, top course.
Condition: Unknown
Due 20 December 1999
Resolved 20 December 1999
Engineering
Issued 20 December 1999
Resolved
Provide proper fuel hose for main engine supply, per 46CFR182.720.
Condition: Unknown
Due 20 December 1999
Resolved 20 December 1999
Engineering
Issued 20 December 1999
Resolved
Replumb generator fuel supply piping to incorporate shutoff valves and remote operability of tank suction valve as per 46CFR182.455.
Condition: Unknown
Due 20 December 1999
Resolved 20 December 1999
Navigation
Issued 20 December 1999
Resolved
Provide current/corrected navigation chart and light list for OPAREA per 46CFR182.420.
Condition: Unknown
Due 20 December 1999
Resolved 20 December 1999
Fire Fighting
Issued 20 December 1999
Resolved
Repair or replace smoke detector in port/aft berthing compartment.
Condition: Unknown
Due 20 December 1999
Resolved 20 December 1999
Fire Fighting
Issued 20 December 1999
Resolved
Install servicing tag on fixed CO2 system per NFA rules.
Condition: Unknown
Due 20 December 1999
Resolved 20 December 1999
Lifesaving
Issued 20 December 1999
Resolved
Obtain and affix EPIRB registration from NOAA.
Condition: Unknown
Due 20 December 1999
Resolved 20 December 1999
Electrical
Issued 20 December 1999
Resolved
Encase or remove dead end wires at starboard aft stairway.
Condition: Unknown
Due 20 December 1999
Resolved 20 December 1999
Lifesaving
Issued 20 December 1999
Resolved
Remove/replace plastic waste containers with non-combustable models meeting46CFR177.405.
Condition: Unknown
Due 20 December 1999
Resolved 20 December 1999
Navigation
Issued 20 December 1999
Resolved
Replace/update compass deviation table.
Condition: Unknown
Due 20 December 1999
Resolved 20 December 1999
Lifesaving
Issued 28 June 1999
Resolved
ATTACH WATERLIGHT TO RING BUOY WITH VIA A 6' LINE WITH CLIP.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Lifesaving
Issued 28 June 1999
Resolved
PROVIDE ADDITIONAL RETRO-REFLECTIVE TAPE ON RING BUOY SO THAT 4 QUADRANTS HAVE 2" WIDE RETRO BANDS ON BOTH SIDES.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Construction/Loadline
Issued 28 June 1999
Resolved
SECURE FIXED BALLAST IN VESSEL BILGES SO IT CANNOT SHIFT POSITION.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Fire Fighting
Issued 28 June 1999
Resolved
INSTALL AN ENGINEROOM FIRE DETECTION SYSTEM PER 46 CFR 181.400(c).
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Fire Fighting
Issued 28 June 1999
Resolved
INSTALL INDEPENDENT MODULAR SMOKE DETECTORS IN EACH OVERNIGHT ACCOMODATION SPACE PER 46 CFR 181.400(c) AND 181.450, OR USCG MOC POLICY LETTER 4-98.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Engineering
Issued 28 June 1999
Resolved
REPLACE FUEL HOSE AT GENERATOR USING MATERIAL MEETING 46 CFR 182.720(e).
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Construction/Loadline
Issued 28 June 1999
Resolved
PROVIDE MACHINERY GUARD FOR FIXED BILGE PUMP.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Construction/Loadline
Issued 28 June 1999
Resolved
LAZARETTE VENTILATION MUST BE RECONFIGURED SO THAT WATERTIGHT INTEGRITY IS MAINTAINED BELOW THE FLUSH WEATHER DECK PER 46 CFR 179 SUBPART C.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Construction/Loadline
Issued 28 June 1999
Resolved
DOUBLE HOSE CLAMP ALL HOSES FOR SYSTEMS SUBJECT TO SEAWATER FLOODING WHERE THEY ARE LOCATED 6" ABOVE THE LOAD WATERLINE OR LOWER.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Construction/Loadline
Issued 28 June 1999
Resolved
PROVIDE A PERMANENT HANDLE FOR REACH ROD SERVING FORE-PEAK BILGE SUCTION VALVE.
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999
Fire Fighting
Issued 8 December 1998
Resolved
Provide plans for installing and upgrading fixed fire extinguishing system for machinery spaces. Plans must be provided, approved and system installed before 11 MAR 99.
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Lifesaving
Issued 8 December 1998
Resolved
Replace battery and show proper operation of waterlight for lifefloat.
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Electrical
Issued 8 December 1998
Resolved
Properly repair and show proper operation of emergency lighting located at stairs leading down to forward cabins.
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Lifesaving
Issued 8 December 1998
Resolved
Remove or properly replace outdate Class A EPIRB with Cat I EPIRB.
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Electrical
Issued 8 December 1998
Resolved
Show proper operation of the internal communications/public address system used in coordinationg man overboard drills between master and crew.
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Construction/Loadline
Issued 8 December 1998
Resolved
Properly install and show proper operation of the newly required high levelbilge alarms in all watertight compartments.
Condition: Unknown
Due 8 December 1998
Resolved 8 December 1998
Electrical
Issued 17 November 1997
Resolved
Correct improper wire connections throughout vessel. (improper wire splices-use of tape and twist on connectors outside boxes in many areas)
Condition: Unknown
Due 1 December 1997
Resolved 12 February 1998
Deck/Cargo
Issued 17 November 1997
Resolved
Replace hoist on boom for vessels small boat prior to operation with passengers aboard and NLT 01DEC97. Wire is wasted and frayed and would likely fail when put to use.
Condition: Unknown
Due 1 December 1997
Resolved 12 February 1998
Documentation
Issued 17 November 1997
Resolved
Provide evidence of a chemical testing program, to include pre-employement testing, EAP, supervisor training and evidence of enrollment of all crewmembers in a random testing program. Prior to ops with any passengers and NLT 01JAN98.
Condition: Unknown
Due 1 January 1998
Resolved 9 April 1998
Deck/Cargo
Issued 17 November 1997
Resolved
Replace/repair forward mast stay NLT 15NOV97.
Condition: Unknown
Due 12 February 1998
Resolved 12 February 1998
Construction/Loadline
Issued 17 November 1997
Resolved
Replace inoperative manual bilge pump.
Condition: Unknown
Due 12 February 1998
Resolved 12 February 1998
Lifesaving
Issued 17 November 1997
Resolved
Repair/replace inoperative waterlight on ring bouy prior to operation and NLT 01NOV97.
Condition: Unknown
Due 12 February 1998
Resolved 12 February 1998
Construction/Loadline
Issued 10 July 1997
Resolved
OPEN THE FORWARD VOID FOR INSPECTION, UNDER THE ESCPAE LADDER FOR THE FORWARD BERTHING SPACE.
Condition: Unknown
Due 10 July 1997
Resolved 10 July 1997
Documentation
Issued 24 May 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 24 May 1996
Resolved 24 May 1996
Documentation
Issued 12 June 1995
Resolved
Provide evidence of enrollment in a drug testing program.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Lifesaving
Issued 12 June 1995
Resolved
Replace/repair one adult and two child lifejackets.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Accommodation/Occupational Safety
Issued 12 June 1995
Resolved
Make permanent repairs to portside aft railing.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Lifesaving
Issued 16 June 1994
Resolved
MARK/STENCIL THE BUOYANT APPARATUS WITH THE VESSEL'S NAME AND THE NUMBER OFPERSONS THE APPARATUS IS CERTIFIED FOR.
Condition: Unknown
Due 2 February 1995
Resolved 2 February 1995
Fire Fighting
Issued 16 June 1994
Resolved
REPAIR OR REPLACE BROKEN RETAINING STRAP ON FIRE EXTINGUISHER BRACKET IN FORWARD CABIN.
Condition: Unknown
Due 2 February 1995
Resolved 2 February 1995
Lifesaving
Issued 16 June 1994
Resolved
PROVIDE/INSTALL APPROVED WEAK-LINK BETWEEN BOUYANT APPARATUS PAINTER AND VESSEL.
Condition: Unknown
Due 2 February 1995
Resolved 2 February 1995
Accommodation/Occupational Safety
Issued 16 June 1994
Resolved
SECURE/LOCK MSD OVERBOARD VALVES WITHIN THREE MILES & TAG/MARK VALVES "DO NOT OPEN INSIDE U.S. WATERS".
Condition: Unknown
Due 2 February 1995
Resolved 2 February 1995
Lifesaving
Issued 16 June 1994
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 2 February 1995
Resolved 2 February 1995
Documentation
Issued 16 June 1994
Resolved
ORIGINAL VESSEL DOCUMENTATION REQUIRED TO BE ONBOARD VESSEL WHILE OPERATING, PHOTO COPY UNSAT.
Condition: Unknown
Due 2 February 1995
Resolved 2 February 1995
Lifesaving
Issued 16 June 1994
Resolved
REPLACE TWO ADULT AND ONE CHILD LIFEJACKETS WHICH DID NOT PASS AND WERE DESTROYED DURING THIS INSPECTION.
Condition: Unknown
Due 2 February 1995
Resolved 2 February 1995
Navigation
Issued 16 June 1994
Resolved
OBTAIN/PLACE ONBOARD CURRANT NOTICE TO MARINERS, TIDE TABLES, CHARTS, PUBS.
Condition: Unknown
Due 2 February 1995
Resolved 2 February 1995
Engineering
Issued 16 June 1994
Resolved
COMPLETE REPAIRS TO RAW WATER COOLING SYS ON SHIPS SERVICE GENERATOR, PROVESAT OPERATION UNDERLOAD OF GEN SET.
Condition: Unknown
Due 2 February 1995
Resolved 2 February 1995
Engineering
Issued 16 June 1994
Resolved
PROVIDE/INSTALL FLAME CUPS/DRIP CONTAINMENT UNDER FUEL OIL FILTERS AS PER 46CFR182.20-40(b)(5).
Condition: Unknown
Due 2 February 1995
Resolved 2 February 1995
Navigation
Issued 16 June 1994
Resolved
MOUSE/LOCKWIRE SHACKEL PIN IN STEERING CABLE CONNECTOR LINK.
Condition: Unknown
Due 2 February 1995
Resolved 2 February 1995
Lifesaving
Issued 16 June 1994
Resolved
REMOVE OLD UNSERVICABLE BUOYANT APPRATUS FROM VESSEL.
Condition: Unknown
Due 2 February 1995
Resolved 2 February 1995
Documentation
Issued 16 June 1994
Resolved
PROVIDE EVIDENCE OF ENROLLEMENT IN DRUG TEST PROGRAM AND TEST RESULTS FOR CREWMEMBERS
Condition: Unknown
Due 2 February 1995
Resolved 2 February 1995
Documentation
Issued 16 June 1994
Resolved
PLACE ORIGINAL COI ONBOARD AND POST AS REQUIRED, PHOTO COPY NOT ACCEPTABLE.
Condition: Unknown
Due 2 February 1995
Resolved 2 February 1995
Construction/Loadline
Issued 21 April 1994
Resolved
RE-FASTEN PLANKS AT EACH FRAME ON BOTH STBD & PORT SIDES FROM THE KEEL TO THE WATERLINE IN AREAS STARTING APPROXIMATELY 6 FEET FWD OF STERN TO APPROX19 FEET FWD OF THE STERN AND ADDITIONAL FRAMING ON EACH SIDE OF THESE AREASAS INDICATED IN SHIPWRIGHT'S PROPOSAL.
Condition: Unknown
Due 30 May 1994
Resolved 3 February 1995
Construction/Loadline
Issued 21 April 1994
Resolved
MAKE REPAIRS TO KEEL IN WAY OF WORM SHOE STARTING APPROX 6' AFT OF STEM FORAPPROX 7', AN ADDITIONAL 6' LENGTH APPROX AMIDSHIP AND SMALLER AREAS THE LENGTH OF KEEL AS MARKED. SCRAPING, BURNING & TREATING THEN FILLING IS ACCEPTED HOWEVER FILLINGS MAY HAVE TO BE REMOVED FOR FUTURE INSPECTIONS.
Condition: Unknown
Due 30 May 1994
Resolved 8 June 1994
Construction/Loadline
Issued 21 April 1994
Resolved
REPLACE A MINIMUM OF 6.5 FEET OF PLANK ON PORT SIDE, FROM THE STERN FORWARD13TH STRAKE UP FROM THE KEEL AND ADDITIONAL PLANK AS PER SHIPWRIGHT'S PROPOSAL.
Condition: Unknown
Due 30 May 1994
Resolved 3 February 1995
Construction/Loadline
Issued 21 April 1994
Resolved
REFASTEN BOTH PORT AND STBD GARBORD STRAKES AT LEAST THE AFT TWO THIRDS OF THE VESSEL TO THE STERN.
Condition: Unknown
Due 30 May 1994
Resolved 3 February 1995
Construction/Loadline
Issued 21 April 1994
Resolved
RE-CORK & CAULK PORT GARBOARD PLANK IN WAY OF THE LENGTH THAT REQUIRES REFASTINING.
Condition: Unknown
Due 30 May 1994
Resolved 3 February 1995
Construction/Loadline
Issued 21 April 1994
Resolved
RE-CORK & CAULK STBD SEAMS WITH 9TH THRU 11TH PLANK UP FROM THE KEEL IN WAYOF THE STERN CONTINUING FORWARD APPROXIMATELY 3-5 FEET AS PER SHIPWRIGHT'S PROPOSAL.
Condition: Unknown
Due 30 May 1994
Resolved 3 February 1995
Lifesaving
Issued 12 October 1993
Resolved
12 PERSON BUOYANT APPARATUS HAS DECAYED TO A LEVEL BEYOND USEFUL SERVICE & NEEDS TO BE REPLACED. THE MATERIAL CONDITION OF THE FLOAT IS IN SUCH A WEATHERED CONDITION IT IS VERY UNLIKELY SATISFACTORY REPAIRS COULD BE MADE.VSL IS RESTRICTED FROM CARRYING PASSENGERS WITH THIS REQUIREMENT OUTSTANDIN
Condition: Unknown
Due 12 October 1993
Resolved 12 October 1993
Accommodation/Occupational Safety
Issued 29 June 1991
Resolved
Install a U.S. Coast Guard approved Marine Sanitation Device for inspected vessel.
Condition: Unknown
Due 29 June 1991
Resolved 29 June 1991
Electrical
Issued 5 June 1987
Resolved
PROVIDE BATTERY BOX COVERS
Condition: Unknown
Due 5 June 1987
Resolved 5 June 1987
Navigation
Issued 5 June 1987
Resolved
PROVIDE MAST HEAD LIGHT OF 225 DEGREES FWD.
Condition: Unknown
Due 5 June 1987
Resolved 5 June 1987
Engineering
Issued 23 June 1986
Resolved
REPAIR LEAKING SEAL AND COVER ON MAIN DIESEL ENGINE SALT WATER COOLING PUMP
Condition: Unknown
Due 23 June 1986
Resolved 23 June 1986
Engineering
Issued 23 June 1986
Resolved
PROVIDE A DOWN COMER PIPE ON FURNACE RELIEF VALVE
Condition: Unknown
Due 23 June 1986
Resolved 23 June 1986
Lifesaving
Issued 23 June 1986
Resolved
PROVIDE CRADLE FOR LIFE FLOAT.
Condition: Unknown
Due 23 June 1986
Resolved 23 June 1986
Lifesaving
Issued 23 June 1986
Resolved
STENCIL CAPACITY OF LIFE FLOAT ON LIFE FLOAT.
Condition: Unknown
Due 23 June 1986
Resolved 23 June 1986
Lifesaving
Issued 23 June 1986
Resolved
PROVIDE ONE (1) ADULT LIFE PRESERVER, CAPACITY OF VESSEL REDUCED TO 25 POB
Condition: Unknown
Due 23 June 1986
Resolved 23 June 1986
Electrical
Issued 13 June 1985
Resolved
PROVIDE ELECTRICAL PLANS FOR EMERGENCY LIGHTING BELOW MAIN DECK. PROIR TO COMPLETION OF THE ABOVE REQUIREMENT YOU ARE PROHIBITED FROM CARRYING MORE THAN SIX PASSENGERS ON OVERNIGHT TRIPS.
Condition: Unknown
Due 13 June 1985
Resolved 13 June 1985
Deck/Cargo
Issued 6 May 1985
Resolved
INSTALL CHECK VALVES IN BILGE SYSTEM.
Condition: Unknown
Due 6 May 1985
Resolved 6 May 1985
Deck/Cargo
Issued 6 May 1985
Resolved
INSTALL SCREW DOWN VALVE ON BILGE SUCTION ON FOREPEAK TANK.
Condition: Unknown
Due 6 May 1985
Resolved 6 May 1985
Deck/Cargo
Issued 6 May 1985
Resolved
INSTALL 2ND ANCHOR ON PORT SIDE.
Condition: Unknown
Due 6 May 1985
Resolved 6 May 1985
Unknown
Issued 6 May 1985
Resolved
INSTALL AND DEMONSTRATE PROPER OPERATION OF RELIEF VALVE ON OIL FURNANCE.
Condition: Unknown
Due 6 May 1985
Resolved 6 May 1985
Electrical
Issued 6 May 1985
Resolved
INSTALL BATTERY COVERS ON BATTERY BOXES.
Condition: Unknown
Due 6 May 1985
Resolved 6 May 1985
Electrical
Issued 6 May 1985
Resolved
PROVIDE PLANS FOR APPROVAL, THEN INSTALL EMERG. LIGHTING BELOW MAIN DECK.
Condition: Unknown
Due 6 May 1985
Resolved 6 May 1985