PGC ARATOS

PGC ARATOS is a 2003 tank ship. The Coast Guard has recorded 19 inspections since 2016, most recently in November 2024, along with 9 deficiencies and 2 operational controls.

Records from 2016 to 2024. Most recent: inspection, 15 November 2024.

Built
2003
Last inspected
15 November 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 November 2024
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9251779
9HA3551
628110
Flag
MALTA
Maury page id
psix-628110

Documentation record

Tonnage as PSIX records it2527 - Convention (Subpart B), Net Ton
9329 - Dead Weight, Metric Ton
13221 - Displacement, Metric Ton
7605 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

19 inspections, each with its date, unit and type; 9 deficiencies with the resolution recorded against each; 2 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 19

15 November 2024 COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8029466
11 November 2024 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8037487
10 October 2022 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7575278
15 April 2022 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7431535
15 April 2022 COC-GAS Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7431934
8 May 2021 Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7192200
21 April 2021 PSC B · Administrative Inspection · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7177017
21 April 2021 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 7180137
5 March 2020 Ballast Water Examination · PSC B · COC-GAS Renew · ISPS Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6921120
28 January 2020 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6897679
31 August 2019 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6803965
31 August 2019 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6804422
13 May 2019 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6683323
5 April 2019 ISPS III Exam · Deficiency Check · COC-GAS Annual · Administrative Inspection · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6641891
5 April 2019 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6727835
5 March 2019 ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6636389
14 May 2018 Administrative Inspection · COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6414046
6 March 2018 Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6360822
20 July 2016 Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5943657

Deficiency record · 9

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 15 November 2024 Resolved
The system should be capable of covering all areas mentioned in 11.3.1 with a uniformly distributed water spray. PSCO observed the forward half of the deck water spray system not providing adequate coverage. 74 solas (20) VII/13.1 93 IGC 11.3.2 16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2024
Resolved 16 November 2024
Resolution: The forward spray water pipes and nozzles were dismantled and thoroughly cleaned out by crew. - Deck water spray system was tested in the presence of the attending surveyor and found providing adequate coverage.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 15 November 2024 Resolved
Where electrical equipment is installed in gas dangerous spaces or zones as provided in 10.1.4, it should be to the satisfaction of the administration. PSCO observed 01 cracked light in the cargo area. 74 SOLAS (20) VII/13.1 93 IGC 10.1.5 16ac
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2024
Resolved 16 November 2024
Resolution: The cracked light located above the Glycol Pumps in the Cargo Compressor Space was replaced with new spare, then tested with satisfactory result.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 15 April 2022 Resolved
FIRE FIGHTING SYSTEMS AND APPLIANCES SHALL BE KEPT IN GOOD WORKING ORDER AND READILY AVAILABLE FOR IMMEDIATE USE. PSCO OBSERVED 02 LEAS IN THE DECK WATER SPRAY FIRE MAIN ON TOP OF COMPRESSOR ROOM ENCLOSURE 74 SOLAS (04) II-2 / 14.2.1.2
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 19 April 2022
Resolved 20 April 2022
Resolution: Vessel submitted class report attesting to the pipe being replaced with a new pipe.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 21 April 2021 Resolved
All steering gear components and the rudder stack shall be of sound and reliable construction to the satisfaction of the administration. Steering gear has a persistent leak calling into question the reliability of the system the leak was noted by Flag on 21FEB21, however vessel was unable to provide documentation of any corrective actions planned. 74SOLAS(01) II-I/29.2.1, 17bc
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 May 2021
Resolution: Received class report attesting to satisfactory repairs.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 5 April 2019 Resolved
06199 The condition of the ship and its equipment should be maintained to conform with the provisions of the code to ensure the ship will remain fit to proceed to sea without danger to the ship or persons aboard or without presenting unreasonable threat to the environment. While examining the semi-enclosed compressor space, the marine chemist was getting up to 35PPM readings on his equipment. 74SOLAS(14) VII/13.1 IGC(93) 1.5.3 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 April 2019
Resolved 5 April 2019
Resolution: Received NKK report acceptance of marine chemist certificate. NKK issued a requirement to implement a manned watch in way of the compressor space to continuously monitor for the presence of VOC and notify the USCG of any reading over 5ppm /stop cargo ops
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 April 2019 Resolved
09209 (electrical)- The administration shall take appropriate steps to ensure uniformity in the implementation and application of the provisions of this part in respect of electrical installations. Two air conditioning units were installed din the overhead in the main switchboard compartment that included spliced cable connections and improper distribution panel installation. Additionally, there were rags stuffed in thru bulkhead run on forward bulkhead in overhead in same compartment. 74SOLAS(14) II-I/40.2 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 5 May 2019
Resolved 2 May 2019
Resolution: 02MAY19 NKK Class report attested to proper installation of electrical junction box and fire stopping material.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 5 April 2019 Resolved
07122 (fire control plan) General arrangement plans shall be permanently exhibited for the guidance of the ship's officers and be in the languages required by the administration. If the language is neither English nor French, a translation into one of these languages shall be included. Fire control plans posted throughout the ship are in Italian and stamped by RINA. Vessel RO is NKK. 74SOLAS(14)/II-2 15.2.4.1 40ac
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2019
Resolved 2 May 2019
Resolution: 02MAY19 NKK Class report stated new fire plans in english were delivered to the vessel and approved by Class NKK.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 April 2019 Resolved
09209 (electrical) Ships shall be designed, constructed and maintained in compliance with electrical requirements of a class society in accordance with provisions of regulation XI-1/1. Breaker labels on the switchboard were labeled in Italian. Working language of the crew is English. 74SOLAS(14) II-I/3.1 40ac
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 2 May 2019
Resolution: 02MAY19 NKK Class report stated crew replaced switchboard italian labeling with English labeling.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 April 2019 Resolved
09209 (electrical) Main switchboards shall be so arranged as to give easy access as may be needed to apparatus without danger to personnel. There was a missing breaker blank on the left side of the main switchboard. 74SOLAS(14) II-1/45.2 40ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2019
Resolved 2 May 2019
Resolution: 02MAY19 NKK Class report stated crew replaced the missing breaker.