MAURY USCG vessel records Sign in
← All vessels

STRETCH DUCK 35

STRETCH DUCK 35 is a 1945 passenger vessel (inspected). The Coast Guard has recorded 38 inspections since 2003, most recently in January 2019, along with 13 deficiencies.

Records from 2003 to 2019. Most recent: inspection, 9 January 2019.

Built
1945
Last inspected
9 January 2019
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI8184
628449
Flag
UNITED STATES
—
Maury page id
psix-628449

Inspections, by type

…with no type recorded2
Years with a record 15 calendar years (2003–2019)
The 38 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 38

9 January 2019 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6608112
20 August 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6520010
31 July 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6520006
26 July 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6520002
13 July 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6519999
12 July 2018 Deficiency Check · Annual Inspection · Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6477205
10 October 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6295376
25 May 2017 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6155100
24 February 2017 Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6094363
27 November 2016 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6097792
25 August 2016 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5994722
5 July 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5931523
16 May 2016 Administrative Inspection · COI Inspection · DAPI Audit · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5878651
1 May 2016 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5882284
23 February 2016 Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5820370
14 October 2015 Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5748785
9 October 2014 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5002135
24 July 2012 Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4375319
21 September 2011 Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4162277
9 December 2009 In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3653022
29 April 2009 Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3453977
25 February 2009 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3426502
26 March 2008 DAPI Audit · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3162968
22 February 2007 Deficiency Check · In-Service Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2891627
25 October 2006 Annual Inspection · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2801967
15 August 2006 Annual Inspection · Examination of Repairs
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2748674
24 October 2005 Examination of Repairs
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2508951
30 August 2005 Administrative Inspection · Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2479456
13 June 2005 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2388819
25 May 2005 Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2361089
26 May 2004 Deficiency Check · COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2079281
29 April 2004 Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2061700
28 April 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2100642
19 March 2004 Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2034654
10 December 2003 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1971953
28 October 2003 Initial Certification
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1924641
31 July 2003 Plan Review "T" Boat
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1862763
24 June 2003 Construction Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1820481

Deficiency record · 13

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 July 2018 Resolved
[name withheld] states the vessel shall have 38 child PFD's. However, the COI is only endorsed for 36 passengers. In additon, the Ops Manual provides marien casualty contact information for Activities Europe. Amend Ops Manual to require 36 Child size PFD's, and SECTOR Mobile's contact number for marine casualties, IAW NVIC 01-01.
Action required: 705 - Other - as specified
Due 18 July 2018
Resolved 13 July 2018
Resolution: The Ops Manual was updated to reflect the requirement to carry 36 child size PFD's, and also provide SECTOR Mobile's contact inforamtion for marine casualties.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 July 2018 Resolved
As per the issued COI, the vessel is required to have a FCC Station License, Safety Radio Certificates, and a Marien Operator's Certificate. Vessel did not have them. Provide the required FCC documentation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2018
Resolved 20 August 2018
Resolution: Provided valid FCC Station License, Radiotelephony Safety Certificate, and Marine Radio Operators Permit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 July 2018 Resolved
Vessel is required to have 36 child size PFD's onboard. Vessel only has 32. provide 36 childe size pfd's.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 13 July 2018
Resolved 13 July 2018
Resolution: Vessel owner/operator provided 36 child size PFD's. Al were properly stowed and labeled.
Engineering › Steering Gear System › Rudder
Issued 14 September 2017 Resolved
The rudder is making contact with the boat ramp when being launched and is causing damage to the rudder. Submit a repair proposal that would prevent the rudder from making contact with the boat ramp when being launched to the local OCMI for review/approval.
Action required: 705 - Other - as specified
Due 13 October 2017
Resolved 10 October 2017
Resolution: Repair proposal was received and reviewed by SECTOR Mobile. The proposal was found to be satisfactory and approved. Owner will notify SECTOR Mobile once repairs are complete to inspect.
Personnel › Training › Familiarization Training
Issued 16 June 2016 Resolved
Limited to Mobile Bay within 1,000 feet of the USS Alabama IAW operational plan.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 July 2016
Resolved 5 July 2016
Resolution: The vessel is authorized to operate in areas specified on COI.
Engineering › Pressure Vessel › Marking and Stamping
Issued 9 December 2009 Resolved
Prove proper installation of pressure vessels used for axel housing low air pressurization system.
Action required: 705 - Other - as specified
Due 9 January 2010
Resolved 25 May 2010
Resolution: Pressure switch (12psi) and relief valve (15 psi) installed to limit pressure to <15 psi.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 22 February 2007 Resolved
Proof test vessels' heat detection system prior to carrying passengers once each day of commercial use. Conduct a visual inspection fore Fire or Smoke on vessels' bilge compartment every 10 minutes while underway with passengers onboard. Upgrade vessels' Heat Detection System to include Electrical Supervision and two sources of power (vital circuit) by dates provided by your company to the OCMI.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 22 August 2007
Resolution: Company upgraded heat detection system to include electrical supervision and 2 sources of power.
Engineering › Reduction Gearing/Clutches › Line Shaft
Issued 15 August 2006 Resolved
annul maintenance required on running gear and drive train.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 25 October 2006
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 29 April 2004 Resolved
Prior to insatlling replacemtn shaft perform NDT to show shaft is satisfactory for service. Provide written report of findings.
Action required: 705 - Other - as specified
Due 29 May 2004
Resolved 28 May 2004
Engineering › Bilge Water Management System › Pump
Issued 29 April 2004 Resolved
Prior ot carrying passengers prove proper operation of Higgins pump by pumping water.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 May 2004
Resolved 28 May 2004
Construction/Loadline › Hull
Issued 19 March 2004 Resolved
Prior to operation make permenet repairs to fractures inway of propellor shaft tunnel by insert. Submit proposal to operate vessel without hitting or draging bottom of rudder backet in all conditions of loading and tide. LEGACY COMPONENT DESC: Bottom Plating
Action required: 705 - Other - as specified
Due 19 April 2004
Resolved 22 March 2004
Communications › Alarms/Indicators
Issued 31 December 2003 Resolved
The flammable vapor detector was operating intermitantly and the operator put the alarm in silence mode.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 December 2003
Resolution: It was found that engine exhaust was entering the engine compartment through a loose bolt on the bow. The bolt was made tight and alarm operated normally.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 28 October 2003 Resolved
Stencil all life jackets and life rings with vessel name.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 October 2003
Resolved 28 May 2004