Records from 2005 to 2023. Most recent: inspection, 7 November 2023.
Inspection history · 32
7 November 2023
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7821796
3 October 2023
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7803767
14 July 2021
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7255842
2 October 2020
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7070106
26 August 2019
Internal Structural Exam · Annual Inspection · Administrative Inspection · DAPI Audit · Drydock Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6796879
26 July 2019
Drydock Extension · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6762607
13 February 2019
Examination of Repairs
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6624983
12 February 2019
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6633157
3 December 2018
In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6591056
11 September 2018
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6537848
14 June 2018
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6445017
11 May 2018
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6408824
20 April 2018
Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6395423
6 April 2018
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6383949
7 October 2017
In-Service Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6298844
17 July 2017
Hull Examination · Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6211540
18 May 2017
Drydock Extension
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6148978
14 July 2016
COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5939056
8 October 2015
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5738236
15 September 2015
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5733238
7 August 2014
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4946601
24 January 2012
Type not recorded
No type recorded · Boat Forces Unit United States Virgin Islands · USCG Southeast District (CGD-SE) · Activity 4230406
24 January 2012
Damage Survey
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4230552
4 January 2012
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4218036
25 July 2011
Plan Review (Other than "T")
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4094048
21 July 2011
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4088974
13 July 2009
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3533226
24 September 2008
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3331542
13 September 2007
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3056492
8 June 2007
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2955135
22 August 2006
Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2755680
8 July 2005
Hull Examination · COI Inspection · Inclining Experiment
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2567916
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 3 December 2018
Resolved
Wastage discovered in the vicinity of the portside aft window outcropping and above the second window from the starboard side on the transom. Wastage resulted in holing of the metal, but was significantly above the waterline. Next scheduled drydocking is prior to 31JUL19. Approved temporary repair utilizing epoxy patches until next drydock.
Action required: 705 - Other - as specified
Due 31 July 2019
Resolved 26 August 2019
Resolution: Repairs completed during DD Examination.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 6 April 2018
Resolved
Fireboy alarm panel (bezel) loose causing inconsistent discharge alarm. Secure bezel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2018
Resolved 20 April 2018
Resolution: Vessel provided documentation that bexel was reattached.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 6 April 2018
Resolved
Engine room ventilation dampers do not fully close. Show proper operation of engine room dampers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2018
Resolved 20 April 2018
Resolution: Vessel provided documentation that dampers are able to close.
Lifesaving › Lifebuoys › Approval
Issued 6 April 2018
Resolved
Lifebuoy faded and does not present proper color. Paint or replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 April 2018
Resolved 20 April 2018
Resolution: Vessel replaced ring buoy.
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 6 April 2018
Resolved
Servicing certificate not available for Fireboy system. Provide servicing certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2018
Resolved 11 May 2018
Resolution: Vessel provided servicing certificate.
Engineering › Lubricating Oil Service System › Gauge
Issued 6 April 2018
Resolved
Engine RPM gauge inoperable. Show proper operation of engine RPM gauge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2018
Resolved 11 May 2018
Resolution: RPM gauge shown to be functioning.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 April 2018
Resolved
Stern light lens cloudy and does not show proper intensity of light. Replace lens.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2018
Resolved 20 April 2018
Resolution: Vessel replaced stern light.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 April 2018
Resolved
Stern light was inoperable Corrected on the spot.
Action required: 10 - Deficiency Rectified
Due 6 April 2018
Resolved 6 April 2018
Resolution: Corrected on the spot. Replaced bulb.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 October 2017
Resolved
Conduct repairs on damaged rails.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2018
Resolution: Rails repaired.
Construction/Loadline › Hull › Side Shell
Issued 7 October 2017
Resolved
Submit repair proposal for damaged hull port bow.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 November 2017
Resolved 6 April 2018
Resolution: Sideshell deemed not needing repair.
Sail Rigging › Chainplates › Materials
Issued 17 July 2017
Resolved
Replace distorted chain plates on both sides of vessel.
Action required: 705 - Other - as specified
Resolved 25 August 2017
Resolution: Vessel replaced all chain plates.
Sail Rigging › Stays/Shrouds › Wires
Issued 17 July 2017
Resolved
Shrouds are wrapped (serving). Make wires available for inspection on main mast rigging that is to be changed to stainless steel.
Action required: 705 - Other - as specified
Resolved 25 August 2017
Resolution: Wire was inspected under wrapping in several places.
Accommodation/Occupational Safety › Potable Water System › General
Issued 17 July 2017
Resolved
Make interior of water tanks available for inspection.
Action required: 705 - Other - as specified
Resolved 31 July 2017
Resolution: Tanks made available.
Sail Rigging › Mast Step › Base
Issued 17 July 2017
Resolved
Remove masts for inspection or present plan for inspection. Complete rigging changeout of main mast.
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 6 April 2018
Resolution: Masts inspected. Rigging renewal ongoing.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 July 2017
Resolved
Repair wasted railing stanchions.
Action required: 705 - Other - as specified
Resolved 31 July 2017
Resolution: Stanchions repaired.
Construction/Loadline › Hull › Bottom Plating
Issued 17 July 2017
Resolved
Remove ballast to facilitate inspection of interior of hull/keel.
Action required: 705 - Other - as specified
Resolved 27 July 2017
Resolution: Ballast removed and area inspected.
Construction/Loadline › Hull › Side Shell
Issued 17 July 2017
Resolved
Remove wasted metal surrounding scuppers in starboard midships bulwark.
Action required: 705 - Other - as specified
Resolved 25 August 2017
Resolution: Wasted metal was removed.
Construction/Loadline › Hull › Side Shell
Issued 17 July 2017
Resolved
Clad weld pitting on port side aft hull plating.
Action required: 705 - Other - as specified
Resolved 31 July 2017
Resolution: Inspected clad weld.
Sail Rigging › Chainplates › Materials
Issued 18 May 2017
Resolved
Forward port chainplate cracked. Repair to the satisfaction of attending USCG marin inspector prior to flying sails on the foremast.
Action required: 705 - Other - as specified
Resolved 6 April 2018
Resolution: Chainplate renewed.
Sail Rigging › Stays/Shrouds › Turnbuckles and Toggles
Issued 14 July 2016
Resolved
Provide plan to correct issues identified during third party rigging inspection and inorporate preventative maintenance.
Action required: 705 - Other - as specified
Due 21 July 2016
Resolved 29 July 2016
Resolution: Implementation plan provided to USCG MI.
Sail Rigging › Stays/Shrouds › Turnbuckles and Toggles
Issued 14 July 2016
Resolved
Complete and log rigging inspections daily, weekly and monthly in accordance with written company procedures.
Action required: 705 - Other - as specified
Due 14 August 2016
Resolved 18 October 2016
Resolution: Vessel provided completed logs showing completed inspections.
Communications › Radio Communications › EPIRB
Issued 14 July 2016
Resolved
Complete and log monthly EPIRB testing.
Action required: 705 - Other - as specified
Due 14 August 2016
Resolved 18 October 2016
Resolution: Vessel provided completed logs showing completed EPIRB testing.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 July 2016
Resolved
Remove expired first aid kit items and provide complete first aid kit.
Action required: 705 - Other - as specified
Due 21 July 2016
Resolved 29 July 2016
Resolution: Replacement items were presented to attending MI.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 14 July 2016
Resolved
Remove excess oil from bilge below engine.
Action required: 705 - Other - as specified
Due 21 July 2016
Resolved 29 July 2016
Resolution: Bilge was pumped to the satisfaction of attending CG MI
Communications › Radio Communications › VHF Radiotelephone
Issued 14 July 2016
Resolved
Mark call sign on emergency broadcast placard.
Action required: 705 - Other - as specified
Due 21 July 2016
Resolved 29 July 2016
Resolution: Call sign was provided.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 14 July 2016
Resolved
Provide records of crew drug awareness training.
Action required: 705 - Other - as specified
Due 21 July 2016
Resolved 29 July 2016
Resolution: Records of training were provided to attending CG MI.
Communications › Radio Communications › EPIRB
Issued 8 October 2015
Resolved
Provide NOAA EPIRB registration and place decal on new EPIRB.
Action required: 705 - Other - as specified
Due 30 October 2015
Resolved 28 October 2015
Resolution: Received new NOAA EPIRB registration form from operator.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 7 August 2014
Resolved
Prove proper operation of engine room ventilation closures IAW 46 CFR 181.20-35 (old T) Remove speaker wire from ventilation duct opening.
Due 14 August 2014
Resolved 11 August 2014
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 7 August 2014
Resolved
Replace water light battery with approved type. Current battery does not meet approval spec and may sink the light.
Due 14 August 2014
Resolved 11 August 2014
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 August 2014
Resolved
Prove proper operation of Mast Head light. Replace burnt out bulb.
Due 14 August 2014
Resolved 11 August 2014
Navigation › Piloting/Steering › Marine Charts
Issued 21 July 2011
Resolved
Provide local charts and nauticle publications.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2011
Resolved 5 October 2012
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 21 July 2011
Resolved
Provide a flame screen for fuel tank vent.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2011
Resolved 5 October 2012
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 21 July 2011
Resolved
Provide alcohol swabs.
Action required: 705 - Other - as specified
Due 22 August 2011
Resolved 5 October 2012
Electrical › Electrical Distribution System (service) › Panelboard
Issued 21 July 2011
Resolved
Provide a totally enclosed distribution panel.
Action required: 705 - Other - as specified
Due 21 August 2011
Resolved 5 October 2012
Stability › Unintentional Flooding › General
Issued 21 July 2011
Resolved
Provide sock/way to prevent downflooding at the bottom of both masts.
Action required: 705 - Other - as specified
Due 21 August 2011
Resolved 5 October 2012
Documentation › Markings/Placards › Warning Signs
Issued 21 July 2011
Resolved
Provide a emergency radio call procedures.
Action required: 705 - Other - as specified
Due 21 August 2011
Resolved 5 October 2012
Stability › Severe Wind/Roll › General
Issued 21 July 2011
Resolved
Certify to the OCMI, in writing, that the vessel complies with stability criteria based on the new Assumed Average Weight Per Person (AAWPP) of 185 pounds or another weight approved by the OCMI.
Action required: 705 - Other - as specified
Due 30 November 2011
Resolved 5 October 2012
Navigation › Piloting/Steering › Compass Deviation Table
Issued 21 July 2011
Resolved
Provide Compass Deviation Table issued after 20 July 2011.
Action required: 705 - Other - as specified
Due 31 July 2011
Resolved 5 October 2012
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 13 September 2007
Resolved
Label bilge high level alrm panel at operating station.
Due 20 September 2007
Resolved 24 September 2007
Resolution: Labeled sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 13 September 2007
Resolved
install approved water light.
Due 20 September 2007
Resolved 24 September 2007
Resolution: water light installed sat.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 22 August 2006
Resolved
Certificate missing. Provide copy
Due 7 September 2006
Resolved 7 September 2006
Resolution: provided sat.
Documentation › Certificates/Documents › Cargo Ship Safety Certificate
Issued 22 August 2006
Resolved
Provide copy of safety radio certifcate.
Due 7 September 2006
Resolved 7 September 2006
Resolution: provided sat.
Documentation › Certificates/Documents › FCC SSL
Issued 8 July 2005
Resolved
Provide vessel with a FCC Telephony Certificate and a radio station License.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 July 2005
Resolved 22 July 2005
Documentation › Logs/Records › Drug Test Records
Issued 8 July 2005
Resolved
Fax the vessel's drug testing program to Sector Boston.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 July 2005
Resolved 22 July 2005
Electrical › Electric Supply System (service) › Cable
Issued 8 July 2005
Resolved
Replace damaged cable to the overhead light in the forward compartment.
Action required: 705 - Other - as specified
Due 22 July 2005
Resolved 22 July 2005
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 8 July 2005
Resolved
Repair DC amp meter and cover blank areas in the main distribution panel box.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 July 2005
Resolved 22 July 2005