Records from 2016 to 2017. Most recent: inspection, 13 November 2017.
Documentation record
Registered dimensions (L × B × D)29.0 ft × 10.0 ft × 3.8 ft
Registered tonnagegross 7 / net 5
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBENTZ BOATS LLC · LEWISTON, ID, UNITED STATES · built 2003
Hull materialAluminum
PropulsionInboard/Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portPHILADELPHIA, PA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 1 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7 - Simplified, Gross Ton
5 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Electrical › Electric Supply System (service) › Cable
Issued 20 April 2017
Resolved
RT01: Horizontal pipes used for protection shall have 6 millimeter holes for drainage every 5 feet. Provide drainage holes in PVC pipe running fore and aft. 46 CFR 183.340 (b)(6) Due 09 MAY2017
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 19 May 2017
Resolution: Attended vessel in person to clear deficiences.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 28 June 2016
Resolved
Does not alarm upon deployment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 July 2016
Resolution: Tested system, all sat.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 28 June 2016
Resolved
Demonstrate proper operation of vapor detection system
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2016
Resolution: Witnessed proper operation of vapor detection.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 28 June 2016
Resolved
Provide DAPI compliance for all crew and employees.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2016
Resolution: Verified crew pre employment.
Engineering › Bilge Water Management System › Pump
Issued 28 June 2016
Resolved
Provide audible bilge high level alarm at operating station.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2016
Resolution: Verified proper operation of bilge high level.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 28 June 2016
Resolved
Provide valid Certificate of Documentation.
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 7 July 2016
Resolution: Verified COD.
Communications › Radio Communications › VHF Radiotelephone
Issued 28 June 2016
Resolved
Make VHF radio DSC capable.
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 7 July 2016
Resolution: Vessel replaced radio, MMSI is imputted, DSC capable.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 June 2016
Resolved
Make anchor light all-round white light. Restricted to daylight operations.
Action required: 705 - Other - as specified
Resolved 7 July 2016
Resolution: Vessel replaced nav light.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 June 2016
Resolved
Provide first-aid kit meeting the requirements of 46CFR160.041.
Action required: 705 - Other - as specified
Due 12 July 2016
Resolved 7 July 2016
Resolution: Vessel replaced first aid kit.
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 28 June 2016
Resolved
Provide servicing report for fire extinguishers, fire boy and vapor detection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2016
Resolution: Verified Tech report.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 28 June 2016
Resolved
Conduct man overboard and fire drills in the presence of a USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 July 2016
Resolution: Conducted drills aboard sister vessel, Ben Franklin. All Sat.