Records from 2016 to 2017. Most recent: inspection, 13 November 2017.
Documentation record
Registered dimensions (L × B × D)29.0 ft × 10.0 ft × 3.8 ft
Registered tonnagegross 7 / net 5
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBENTZ BOATS LLC · LEWISTON, ID, UNITED STATES · built 2003
Hull materialAluminum
PropulsionInboard/Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portPHILADELPHIA, PA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 1 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7 - Simplified, Gross Ton
5 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 20 April 2017
Resolved
RT02: Resecure ventilation in engine room on STB side. 46 CFR 182.460 Due 09 MAY 2017
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 19 May 2017
Resolution: Attended vessel to clear def. all sat
Electrical › Electric Supply System (service) › Cable
Issued 20 April 2017
Resolved
RT01: Horizontal pipes used for protection shall have 6 millimeter holes for drainage every 5 feet. Provide drainage holes in PVC pipe running fore and aft. 46 CFR 183.340 (b)(6) Due 09 MAY2017
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 19 May 2017
Resolution: Attended vessel to verify worklist item. worklist cleared.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 28 June 2016
Resolved
Fire boy does not operate as designed. No Alarm, will not start in over ride. Prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 June 2016
Resolved 7 July 2016
Resolution: Verified alarm
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 28 June 2016
Resolved
Demonstrate proper operation of vapor detection system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 June 2016
Resolved 7 July 2016
Resolution: USCG marine inspector witnessed proper operation of vapor detection.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 28 June 2016
Resolved
Prove DAPI compliance for all crew/employees.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 June 2016
Resolved 7 July 2016
Resolution: Verified crew pre employment.
Engineering › Bilge Water Management System › Pump
Issued 28 June 2016
Resolved
Provide Bilge high level alarm at operating station.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 June 2016
Resolved 7 July 2016
Resolution: witnessed bilge high level operation.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 28 June 2016
Resolved
Provide valid COD
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 1 August 2016
Resolution: Varified vessel recived COD.
Communications › Radio Communications › VHF Radiotelephone
Issued 28 June 2016
Resolved
Prove VHF radio DSC capable
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 7 July 2016
Resolution: Vessel installed new radio with DSC, MMSI imputted. All Sat.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 June 2016
Resolved
Make anchor light all around white light. Restricted to day light ops.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 June 2016
Resolved 7 July 2016
Resolution: Vessel replaced the light.
Electrical › Lighting (service) › Lighting Fixture
Issued 28 June 2016
Resolved
Secure dead end wiring, starboard side, under seat.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 July 2016
Resolved 7 July 2016
Resolution: Dead end wire was removed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 June 2016
Resolved
Provide first aid kit metting 46CFR 160.041
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 July 2016
Resolved 7 July 2016
Resolution: Vessel replaced first aid kit
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 28 June 2016
Resolved
Provide Tech fire servicing report for fire extinguisher, fire boy and vapor detection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 June 2016
Resolved 7 July 2016
Resolution: Verified Tech report.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 28 June 2016
Resolved
Conduct man overboard and fire drill in present of USCG Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 June 2016
Resolved 7 July 2016
Resolution: Conducted MOB drills with the Crew.