Records from 2016 to 2025. Most recent: inspection, 21 August 2025.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 15
21 August 2025
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8207327
23 April 2025
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8077102
14 August 2024
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7980871
21 May 2024
Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7916148
21 August 2023
COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7733317
21 April 2023
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7668726
19 January 2022
In-Service Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7382459
6 May 2021
Hull Examination · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7190849
4 March 2021
Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7150051
8 August 2019
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6776922
26 July 2018
Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6491465
5 June 2018
Excursion Permit · Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6435158
6 September 2017
Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6261215
12 October 2016
Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6020701
23 August 2016
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5956633
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 21 August 2023
Resolved
Replace HRU on EPIRB. Vessel restricted to operating not more than 3 miles from land until corrected.
Action required: 705 - Other - as specified
Due 21 September 2023
Resolved 12 September 2023
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 21 August 2023
Resolved
Provide 5 additional day/night flares. Vessel restricted to a Lakes Bays and Sounds route until corrected.
Action required: 705 - Other - as specified
Due 1 September 2023
Resolved 22 August 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 21 August 2023
Resolved
Prove operation of oil pressure gauge at operating station.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 March 2024
Resolved 21 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 August 2023
Resolved
Prove operation of Bilge Pump Energized indicator at operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2023
Resolved 12 September 2023
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 17 June 2021
Resolved
Provide serviced liferaft onboard. Vessel restricted to operating not more than 1 mile from land until corrected.
Action required: 705 - Other - as specified
Due 17 July 2021
Resolved 30 June 2021
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 17 June 2021
Resolved
Prove operation of fixed firefighting system restart feature.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2021
Resolved 30 June 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 June 2021
Resolved
Provide Alco-test kits.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 23 June 2021
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 17 June 2021
Resolved
Prove operation of propane shutoff feature when propane alarm is activated. Propane copoking appliances not to be used when passengers are aboard until corrected.
Action required: 705 - Other - as specified
Due 17 July 2021
Resolved 13 July 2021
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 March 2021
Resolved
Vessel is overdue for a credit hull exam and the annual COI inspection. Vessel may not carry passengers for hire until these required inspections are conducted by an attending Coast Guard Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 May 2021
Resolved 30 June 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 September 2019
Resolved
Prove operation of fixed system override switch and discharge alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 October 2019
Resolved 22 October 2019
Resolution: Attended vessel. Tested alarms/shutdowns with no defs noted.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 30 September 2019
Resolved
Replace Expired HRU. Vessel restricted to operating not more than 3 miles from land until cleared.
Action required: 705 - Other - as specified
Due 30 September 2019
Resolved 22 October 2019
Resolution: Attended vessel. HRU replaced.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 30 September 2019
Resolved
Confirm EPIRB is operating satisfactory (proper test). Vessel restricted to operating not more than 3 miles from land until cleared.
Action required: 705 - Other - as specified
Due 30 September 2019
Resolved 22 October 2019
Resolution: Attended vessel. EPIRB tested sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 September 2019
Resolved
Provide FCC Safety Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2019
Resolved 22 October 2019
Resolution: Certificate issued.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 September 2019
Resolved
Address wiring/seal on propane solenoid.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2019
Resolved 22 October 2019
Resolution: Attended vessel. Deficiency corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 September 2019
Resolved
Replace broken handle on fuel shutoff.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2019
Resolved 22 October 2019
Resolution: Attended vessel. New handle installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 September 2019
Resolved
Replace expired Alco-Test kits.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2019
Resolved 24 October 2019
Resolution: Attended vessel. New test kits onboard.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 26 July 2018
Resolved
Prove operation of running lights and stern light. Vessel may not operate at night or during periods of low visibility until corrected.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 September 2018
Resolved 1 September 2018
Resolution: Lights repaired and operational.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 7 September 2017
Resolved
Service Fire Equipment (fixed and portable)
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 29 September 2017
Communications › Radio Communications › EPIRB
Issued 7 September 2017
Resolved
Replace EPIRB HRU.
Action required: 705 - Other - as specified
Due 30 September 2017
Resolved 29 September 2017
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 7 September 2017
Resolved
Provide alcohol test kits.
Action required: 705 - Other - as specified
Due 7 September 2017
Resolved 29 September 2017
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 23 August 2016
Resolved
Affix reflective tape to both sides of the buoy, renew tape were worn.
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 15 September 2016
Resolution: New reflective tape was applied to both ring buoys.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 23 August 2016
Resolved
Tighten the hand rails along the main deck Port & stbd for increased stability and passenger safety.
Action required: 705 - Other - as specified
Due 23 September 2016
Resolved 15 September 2016
Resolution: Hand rails were tighten & verified by Master.
Fire Fighting › Fire Bucket › Availability
Issued 23 August 2016
Resolved
Replace the missing fire bucket; vsl to have 3 onboard.
Action required: 705 - Other - as specified
Due 23 September 2016
Resolved 17 October 2016
Resolution: Three fire buckets were onboard.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 23 August 2016
Resolved
Mount the B-1 fire extinguisher near the operating station using the approved bracket.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 September 2016
Resolved 15 September 2016
Resolution: The B-1 was mounted in front of the helm, inside a enclosure to protect from the weather.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 23 August 2016
Resolved
Provide a 3rd party service report for the portable & Fireboy fire extinguishing equipment.
Action required: 705 - Other - as specified
Due 23 September 2016
Resolved 15 September 2016
Resolution: All portable fire extinguisher & the Fixed system were serviced.