MAURY USCG vessel records Sign in
← All vessels

ANGLER

ANGLER is a 2003 passenger vessel (inspected). The Coast Guard has recorded 33 inspections since 2002, most recently in January 2026, along with 37 deficiencies.

Records from 2002 to 2026. Most recent: inspection, 22 January 2026.

Built
2003
Last inspected
22 January 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI7655
630332
Flag
UNITED STATES
367052820, 367730840 (licence lapsed)
Maury page id
psix-630332

Inspections, by type

Years with a record 20 calendar years (2002–2026)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)64.9 ft × 20.0 ft × 10.0 ft
Registered tonnagegross 86 / net 69
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPERFORMANCE MARINE INC · ARUNDEL, ME, UNITED STATES · built 2003
Hull materialFRP (Fiberglass)
PropulsionJet Drive
Hull shapeShip
Hull configurationMonohull
Hailing portBAR HARBOR, ME
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 24 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it86 - Simplified, Gross Ton
69 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDI7655MMSI 367730840 · expired · compulsorily equipped · granted 28 April 2016, cancelled 27 June 2026
WDC6200MMSI 367052820 · expired · compulsorily equipped · granted 28 June 2005, cancelled 29 August 2015
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 33

22 January 2026 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8300086
1 May 2025 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8117826
21 February 2025 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8079686
3 May 2024 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7901766
5 June 2023 Administrative Inspection
Administrative · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 7703641
5 April 2023 Internal Structural Exam · Deficiency Check · COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7660431
27 April 2022 Deficiency Check · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7439128
14 April 2022 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7431146
25 March 2021 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7170417
4 March 2021 Examination of Repairs · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7141409
1 July 2020 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7089782
3 October 2019 In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6820810
10 September 2019 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6808125
7 May 2019 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6678542
4 April 2019 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6655335
26 April 2018 COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6395590
9 May 2017 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6139864
28 April 2017 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6134472
28 April 2016 Deficiency Check · Annual Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5865701
2 May 2014 MARPOL Annex V Examination · DAPI Audit · Annual Inspection · MARPOL Annex IV Survey · Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4849055
7 May 2012 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4304029
21 February 2012 Plan Review "T" Boat
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4248295
12 May 2009 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3453177
17 March 2009 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3432961
30 June 2008 COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3175409
24 April 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2884244
11 April 2007 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3085422
28 June 2005 Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2405580
28 March 2005 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2321274
2 August 2004 Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2153184
2 July 2003 Deficiency Check · Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1830845
6 June 2003 Simplified Stability Test
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1827559
7 November 2002 Construction Oversight · Plan Review "T" Boat · Simplified Stability Test
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1830842

Deficiency record · 37

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 April 2023 Resolved
Owner/Operator to make vessel available for drydock and internal structural examination as required by 46 CFR 176.600. Vessel has surpassed interval dates as of 31Mar23. Vessel to receive credited examination prior to carriage of passengers. 46CFR176.600
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 May 2023
Resolution: Vessel underwent satisfactory drydock and internal structural exams.
07 - Fire Safety › N/A - No Subsystem › Fire patrol
Issued 27 April 2022 Resolved
Vessels that have overnight accommodations for passengers must submit plans to the cognizant OCMI by 28Mar2022 for the installation and use of a monitoring device to ensure the wakefulness of the watchmen. The monitoring device must ensure the wakefulness of the crew in the event that the watchman is unresponsive; Remain operable during the nighttime watch; and Be arranged to ensure proper coverage of the passenger accommodation spaces, common areas, and spaces with potential fire hazards. Submit plans to the OCMI by 27May2022.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 May 2022
Resolved 21 July 2022
Resolution: Vessel opted to exclude overnight passengers from the COI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 March 2021 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure and personnel injury. Main feed fuel lines for all 3 main engines are wasted and no longer serviceable.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 March 2021
Resolution: Confirmed installation of new hoses on all 3 main engines.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 25 March 2021 Resolved
A hatch exposed to the weather must be watertight. Port side hatch to machinery space is not watertight.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 March 2021
Resolution: Confirmed hatch caulking had been replaced, rendering it watertight.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 23 March 2021 Resolved
Griddle rated for over 250 degrees temperature needs to meet the following regulations: 46 CFR 177.405, 46 CFR 177.410, 46 CFR 177.600, 46 CFR 181.400, 46 CFR 181.425 & 46 CFR 184.200. Properly install all necessary structural fire protection, fire detection, fixed fire extinguishing system & other requirements as per the regulations to satisfaction of CG marine inspector or properly tag out/remove griddle from vessel prior to carrying passengers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 14 April 2022
Resolution: Griddle has been removed.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 3 October 2019 Resolved
The construction and arrangement of berths and other furniture must allow free and unobstructed access to each berth. Each berth must be immediately adjacent to an aisle leading to a means of escape from the accommodation space. An aisle alongside a berth must be at least 24 inches wide. The aisle alongside the berth leading to the emergency egress hatch is only 16 inches in width, creating an obstruction to the secondary means of escape from the space. Must be rectified prior to the carriage of overnight passengers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 4 March 2021
Resolution: The aisle alongside the berth is at least 24 inches wide.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 3 October 2019 Resolved
All passenger accommodations must be arranged and equipped to provide for the safety of the passengers in consideration of the route, modes of operation, and speed of the vessel. Ladders or other means to facilitate escape are not provided on emergency egress hatches in either forward or aft accommodation spaces. Must be rectified prior to the carriage of overnight passengers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 4 March 2021
Resolution: Ladders have been provided
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 7 May 2019 Resolved
Port FWD hatch has wood rot. Repair or replace wood. Repairs will be made in Dry dock scheduled for the winter of 2019.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 June 2019
Resolved 7 May 2019
Resolution: Made repairs to wood as hatchway.
Construction/Loadline › Structures › Superstructure
Issued 4 May 2017 Resolved
SS aft corner of superstructure, minor hole in bulkhead to flooring connection. Inside engine room air duct, flooring rotten (plywood - 2 sheets 1/2" thickness to be replaced in kind.) Laminate will be replaced at location and glassed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 May 2017
Resolution: Vessel glassed area of concern in kind, all sat.
Fire Fighting › Structural - B Class Divisions › Windows
Issued 28 April 2016 Resolved
Window in Pilot house is cracked.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 May 2016
Resolved 6 May 2016
Resolution: Window has been replaced.
Engineering › Sea-water System (primary cooling) › Piping
Issued 2 May 2014 Resolved
Port MDE sea suction hose between sea valve & filter, outer casing cracked, replace in kind.
Action required: 705 - Other - as specified
Due 16 May 2014
Resolved 6 May 2014
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 7 May 2012 Resolved
Provide copy of company's drug and alcohol policy IAW 46 CFR 16.401.
Action required: 705 - Other - as specified
Due 7 June 2012
Resolved 7 May 2012
Resolution: Vessel representative provided company policy. Deficiency cleared.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 7 May 2012 Resolved
Provide EAP phone # and EAP information for crew members IAW 46 CFR 16.401.
Action required: 705 - Other - as specified
Due 7 June 2012
Resolved 7 May 2012
Resolution: Vessel representative provided EAP information. Deficiency cleared.
Communications › Audible Communications › Bell
Issued 7 May 2012 Resolved
Provide bell IAW Navigation Rules, Annex III, 33 CFR 86.23.
Action required: 705 - Other - as specified
Due 7 June 2012
Resolved 1 May 2013
Resolution: Bell was on board for the inspection. Deficiency cleared.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 7 May 2012 Resolved
Provide current copy of tides and currents on board IAW 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 7 June 2012
Resolved 7 May 2012
Resolution: Vessel representative provided new tides and currents publication. Deficiency cleared.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 7 May 2012 Resolved
Ensure EPIRB monthly checks are logged IAW 46 CFR 185.524.
Action required: 705 - Other - as specified
Due 12 May 2012
Resolved 7 May 2012
Resolution: Vessel representative logged EPIRB check after operational test. Deficiency cleared.
Documentation › Markings/Placards › Capacity Marking
Issued 7 May 2012 Resolved
Change max passenger count for upper deck to 24.
Action required: 705 - Other - as specified
Due 12 May 2012
Resolved 1 May 2013
Resolution: Maximum passenger count labeled. Deficiency cleared.
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 May 2012 Resolved
Replace hose for raw water exhaust on starboard main engine.
Action required: 705 - Other - as specified
Due 7 June 2012
Resolved 1 May 2013
Resolution: Raw water exhaust hose replaced. Deficiency cleared.
Communications › Radio Communications › EPIRB
Issued 2 August 2004 Resolved
PROVIDE PROOF OF CURRENT REGISTRATION FOR THE EPIRB WITH NOAA
Action required: 705 - Other - as specified
Due 27 August 2004
Resolved 1 May 2005
Resolution: Proof provided of current registration.
Documentation › Certificates/Documents › FCC SSL
Issued 2 August 2004 Resolved
PROVIDE PROOF OF CURRENT RADIO STATION LICENSE FROM FCC.
Action required: 705 - Other - as specified
Due 27 August 2004
Resolved 1 May 2005
Resolution: Provided proof of current radio station licence from fcc.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 August 2004 Resolved
PROVIDE NON-CORROSIVE CLIP FOR FLOAT LIGHT ATTACHMENT TO LIFE RING.
Action required: 705 - Other - as specified
Due 27 August 2004
Resolved 28 April 2005
Resolution: Non-corrosion clip provided for float light attachment to life ring.
Documentation › Markings/Placards › Warning Signs
Issued 2 August 2004 Resolved
RELABEL LIFE JACKET BOXES, EMERGENCY FUEL OIL SHUT OFFS, AND BELOW DECK CABIN EMERGENCY ESCAPES.
Action required: 705 - Other - as specified
Due 27 August 2004
Resolved 28 April 2005
Resolution: All labels were permanently affixed and correct.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 August 2004 Resolved
POST ALL REQUIRED DOCUMENTATION ( COI, EMERGENCY PROCEDURES, FCC DOCUMENTS, ETC.).
Action required: 705 - Other - as specified
Due 27 August 2004
Resolved 28 April 2005
Resolution: All required documentation was posted.
Lifesaving › Hand Flares › Storage
Issued 2 August 2004 Resolved
PROVIDE BRIGHT COLORED WATERTIGHT BOX LABELED "DISTRESS SIGNALS" FOR THE FLARES.
Action required: 705 - Other - as specified
Due 27 August 2004
Resolved 28 April 2005
Resolution: Box provided and cleary labeled.
Documentation › Markings/Placards
Issued 2 July 2003 Resolved
OBTAIN EMERGENCY INSTRUCTIONS AND LIFE JACKET DONNING PLACARD.
Action required: 705 - Other - as specified
Resolved 29 July 2003
Documentation › Logs/Records
Issued 2 July 2003 Resolved
PROVIDE NAVIGATION PUBS.
Action required: 705 - Other - as specified
Resolved 29 July 2003
Lifesaving
Issued 2 July 2003 Resolved
PUT NAME OF VESSEL ON LIFERING.
Action required: 705 - Other - as specified
Resolved 29 July 2003
Documentation › Logs/Records
Issued 2 July 2003 Resolved
PROVIDE LIFESAVING EQUIPMENT MAINTENANCE LOG BOOK. LEGACY COMPONENT DESC: Logbook/Record (unofficial)
Action required: 705 - Other - as specified
Resolved 29 July 2003
Documentation › Logs/Records
Issued 2 July 2003 Resolved
PROVIDE CURRENT TRAINING LOG BOOK.
Action required: 705 - Other - as specified
Resolved 18 July 2003
Operations/Management › Passenger Operations
Issued 2 July 2003 Resolved
PROVIDE ADEQUATE SAFETY ORENTATION FOR PASSENGERS. LEGACY COMPONENT DESC: Safety Orientation
Action required: 705 - Other - as specified
Resolved 18 July 2003
Operations/Management › Passenger Operations
Issued 2 July 2003 Resolved
PROVIDE METHOD TO ACCOUNT FOR ALL PASSENGERS ONBOARD.
Action required: 705 - Other - as specified
Resolved 18 July 2003
Operations/Management › Drills/Instruction
Issued 2 July 2003 Resolved
CONDUCT FIRE DRILL IN PRESENCE OF A MARINE INSPECTOR. LEGACY COMPONENT DESC: Fire
Action required: 705 - Other - as specified
Resolved 18 July 2003
Operations/Management › Drills/Instruction
Issued 2 July 2003 Resolved
CONDUCT A MAN OVERBOARD DRILL IN THE PRESENCE OF A MARINE INSPECTOR. LEGACY COMPONENT DESC: Man Overboard Recovery
Action required: 705 - Other - as specified
Resolved 18 July 2003
Construction/Loadline › Hull
Issued 2 July 2003 Resolved
PER MSC LETTER 16710/P009411/rrb DATED 7 JULY 2003: PROVIDE PROOF THAT THE HOSES LEADING FROM STRAINER TO GENERATOR MEET SAE J1942 LEGACY COMPONENT DESC: MSC LETTER- GEN HOSES
Condition: Unknown
Due 31 August 2003
Resolved 18 July 2003
Resolution: Hoses do not meet SAE J1942 however they are good quality marine exhaust hose. The generator is designed for a slip on hose connection and the owner agreed to use t-bolt style hose clamps at each connection.
Construction/Loadline › Hull
Issued 2 July 2003 Resolved
PER MSC LETTER 16710/P009411/mjc SERIAL Nr E1-0305671, PROVIDE RESULTS OF ENGINE TESTS. LEGACY COMPONENT DESC: MSC LETTER/ENGINE TESTS
Condition: Unknown
Due 31 July 2003
Resolved 24 July 2003
Resolution: Spoke with dealer. Rcvd copy of their letter dtd 10 Jul 2003 stating that the jets were installed per service manual and installation manual and Designers manual.
Fire Fighting › Miscellaneous Items
Issued 2 July 2003 Resolved
PROVIDE INSULATION INTHE ENGINE ROOM OVER HEAD IWO ACCESS LADDER LEGACY COMPONENT DESC: INSULATION
Condition: Unknown
Due 31 July 2003
Resolved 18 July 2003
Engineering › Generator (propulsion/auxiliary-electric)
Issued 2 July 2003 Resolved
DOUBLE CLAMP STBD ENG ROOM GENERATOR RAW WATER SUPPLY (FROM STRAINER TO GENERATOR) LEGACY COMPONENT DESC: HOSES
Condition: Unknown
Due 31 July 2003
Resolved 18 July 2003

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.