MAYA

MAYA is a 2003 tank ship. The Coast Guard has recorded 15 inspections since 2016, most recently in March 2021, along with 8 deficiencies and 1 operational control.

Records from 2016 to 2021. Most recent: inspection, 11 March 2021.

Built
2003
Last inspected
11 March 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 March 2021
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9256016
630337
Flag
MARSHALL ISLANDS
Maury page id
psix-630337

Documentation record

Tonnage as PSIX records it39085 - Convention (Subpart B), Gross Ton
19936 - Convention (Subpart B), Net Ton
68467 - Dead Weight, Metric Ton
81464 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

15 inspections, each with its date, unit and type; 8 deficiencies with the resolution recorded against each; 1 operational control with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 15

11 March 2021 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7154362
11 March 2021 Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7154366
20 January 2021 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7127423
2 May 2020 COC-TVE Annual
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6942462
31 January 2020 PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6900087
24 April 2019 In-Service Inspection · ISPS II Exam · COC-TVE Annual · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6669289
12 December 2018 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6596644
7 September 2018 COE-Administrative
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6535332
7 July 2018 Administrative Inspection · COE-Administrative
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6470336
3 January 2018 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6330424
2 August 2017 PII Safety Exam · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6228394
1 August 2017 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6226855
31 July 2017 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6307586
7 January 2017 COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6065099
9 March 2016 NPV Safety Exam · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5830318

Deficiency record · 8

11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 31 January 2020 Resolved
BEFORE LEAVING PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFESAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. 03 LIFEBUOYS WITH SELF IGNITING LIGHTS DID NOT HAVE A LINE ATTACHING THE LIFEBUOYS TO THE LIGHTS. SOLAS 74 (2014) III/20.2
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 31 January 2020
Resolved 31 January 2020
Resolution: SHIPS PERSONNEL PROPERLY ATTACHED LINES CONNECTING LIFEBUOYS TO THE LIGHTS.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 31 January 2020 Resolved
THE CONDITION OF THE SHIP & ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE CURRENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEDD TO SEA. 04 SELF CLOSING DOORS COULD NOT SELF- CLOSE. SOLAS 74 (09) I/11(a)
Action required: 10 - Deficiency Rectified
Due 31 January 2020
Resolved 31 January 2020
Resolution: SHIPS PERSONNEL ADJUSTED DOORS TO ALLOW THEM TO PROPERLY CLOSE.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 April 2019 Resolved
Personal equipment shall consist of protect clothing of material to protect the skin from the heat radiating from the fire and from burns and scalping by steam. The outer surface shall be water resistant. 04 firefighting outfits have excessive flaking of reflective material. 01 of these outfits has a hole in the crotch of the pants. 01 outfit jacket does not have functioning buttons. FFS CODE 3.2.1.1.1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 April 2019
Resolution: Deficiency Downgraded to Code 10 ac after Class reviewed condition.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 24 April 2019 Resolved
The machinery, boilers, and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed temporary patch on salt water outlet line from COPT condenser circulating pump (IVO Valve 136 VPW) to COPT Condenser.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 May 2019
Resolution: Vessel replaced salt water outlet line and provided Class Surveyor report.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 24 April 2019 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed leaking fuel drain on diesel service tank.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 April 2019
Resolution: Leaking fuel drain repaired by crew. Deficiency Downgraded to Code 10.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 24 April 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulation to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed excessive rust and possible non-approved patches on starboard sea chest. Request class clarification on condition of sea chest. **AMENDMENT: EXCESSIVE RUST WAS OBSERVED ON STARBOARD SEA CHEST STRAINER (25APR2019)**
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 April 2019
Resolution: Deficiency was downgraded upon learning that system was sea chest strainer and not sea chest as originally suspected.
Engineering › Steam Boiler (auxiliary/waste heat) › Fan Motor
Issued 9 March 2016 Resolved
All electrical apparatus shall be so constructed and so installed as to not cause injury when handled in the normal manner. The vessel's boiler blower fan motor has exposed 440V wires. 74 SOLAS (04 Cons) II-1/45.1.3
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2016
Resolution: received class report attesting to the proper repair/operation.
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 9 March 2016 Resolved
Arrangements for the storage, distribution and utilization of other flammable oils. Shall be such as to ensure the safety of the ship and persons on board. Vessel's fuel oil transfer pump is leaking into engine room. 74 SOLAS (04 Cons) II-2/4.2.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2016
Resolution: received class report attesting to the proper repair/operation.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.