MAURY USCG vessel records Sign in
← All vessels

SOUTHERN BREEZE

SOUTHERN BREEZE is a 1994 freight ship. The Coast Guard has recorded 2 inspections in 2000, along with 28 deficiencies — 7 with no resolution recorded —.

Records in 2000. Most recent: inspection, 1 September 2000.

Built
1994
Last inspected
1 September 2000
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9117727 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
PHILIPPINES
—
Maury page id
psix-6308

Inspections, by type

…with no type recorded2
…past their stated due date7
Years with a record 1 calendar year (2000)
The 2 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 26 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it4062 - Regulatory (Subpart C or D), Net Ton
13540 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.

Inspection history · 2

1 September 2000 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 281890
2 May 2000 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 277340

Deficiency record · 28

Fire Fighting
Issued 1 September 2000 No resolution recorded
INCCORECT FIRE CONTROL PLAN.
Condition: Unknown
Due 2 November 2000 — due date passed with no resolution recorded
Lifesaving
Issued 1 September 2000 No resolution recorded
LIMIT SWITCHES ON STARBOARD LIFEBOAT DAVIT ASSEMBLY NEED TO BE CORRECTED.
Condition: Unknown
Due 2 November 2000 — due date passed with no resolution recorded
Documentation
Issued 1 September 2000 No resolution recorded
CREW FAMILIARIZATION AND WRITTEN INSTRUCTIONS FROM COMPANY.
Condition: Unknown
Due 2 November 2000 — due date passed with no resolution recorded
Navigation
Issued 2 May 2000 Resolved
Obtain the current edition of International and Inland Rules of Road (COLREGS). 33CFR164.33
Condition: Unknown
Due 11 September 2000
Resolved 11 September 2000
Fire Fighting
Issued 2 May 2000 Resolved
Provide gasket for international shore connection. SOLAS 74 II-2/19
Condition: Unknown
Due 11 September 2000
Resolved 11 September 2000
Lifesaving
Issued 2 May 2000 Resolved
Provide manufacturer's operating and maintenance manual for both lifeboat davit assemblies. SOLAS III/19.3
Condition: Unknown
Due 11 September 2000
Resolved 11 September 2000
Fire Fighting
Issued 2 May 2000 No resolution recorded
Update all copies of the Fire Control Plan to indicate the correct locationof emergency equipment and proper deck name identification. SOLAS 74 II- 2/20
Condition: Unknown
Due 3 May 2000 — due date passed with no resolution recorded
Lifesaving
Issued 2 May 2000 No resolution recorded
Conduct and document crew vessel familiarization. STCW VI/1, A-VI/1
Condition: Unknown
Due 3 May 2000 — due date passed with no resolution recorded
Documentation
Issued 2 May 2000 No resolution recorded
Provide company written instructions to master setting forth policies/procedures for vessel familiarization. STCW I/14, A-I/14
Condition: Unknown
Due 3 May 2000 — due date passed with no resolution recorded
Lifesaving
Issued 2 May 2000 No resolution recorded
Prove proper operation of both limit switches on the stbd lifeboat davit assembly. SOLAS 74 III/19.2
Condition: Unknown
Due 3 May 2000 — due date passed with no resolution recorded
Lifesaving
Issued 2 May 2000 Resolved
Prove proper operation of seized swivel head wire rope guides on each end of the stbd lifeboat davit assembly. SOLAS 74 III/19.2
Condition: Unknown
Due 11 September 2000
Resolved 11 September 2000
Lifesaving
Issued 2 May 2000 Resolved
Conduct and log weekly test of survival craft, lifeboat engines and generalalarm system. SOLAS 74 III/19.6
Condition: Unknown
Due 11 September 2000
Resolved 11 September 2000
Lifesaving
Issued 2 May 2000 Resolved
Repair or renew wasted and seized sheave (above and closest to forward winch drum) on stbd lifeboat davit assembly. SOLAS 74 III/19.2
Condition: Unknown
Due 11 September 2000
Resolved 11 September 2000
Lifesaving
Issued 2 May 2000 Resolved
Log and maneuver each lifeboat in the water at least once every three months during an abandon ship drill. SOLAS 74 III/18.3.6
Condition: Unknown
Due 11 September 2000
Resolved 11 September 2000
Engineering
Issued 2 May 2000 Resolved
Post operating instructions for emergency lube oil and fuel oil shutoff valve controls located at the control station, car deck. SOLAS 74 II- 2/15.2.5
Condition: Unknown
Due 11 September 2000
Resolved 11 September 2000
Engineering
Issued 2 May 2000 Resolved
Install fuel shutoff valve at the fuel tank connection for the emergency generator. This valve shall be operable from outside the emergency generator space. SOLAS 74 II-2/15.2.5
Condition: Unknown
Due 11 September 2000
Resolved 11 September 2000
Construction/Loadline
Issued 2 May 2000 Resolved
Secure (bolt in place) manhole cover in transverse watertight bulkhead between the main engine room and shaft alley/MSD space. SOLAS 74 I/11
Condition: Unknown
Due 11 September 2000
Resolved 11 September 2000
Fire Fighting
Issued 2 May 2000 Resolved
Provide documentation from class society that the shaft alley/MSD space canbe used to store flammables/combustibles, a fire detection system is not required in this space, and only one means of escape is suitable. SOLAS 74 I/11
Condition: Unknown
Due 11 September 2000
Resolved 11 September 2000
Fire Fighting
Issued 2 May 2000 Resolved
Remove hold back device from stairway door located on the Bridge deck. SOLAS II-2/46
Condition: Unknown
Due 11 September 2000
Resolved 11 September 2000
Lifesaving
Issued 2 May 2000 Resolved
Prove operation of seized sea water inlet valves, both lifeboats. SOLAS 74 III/19.2
Condition: Unknown
Due 11 September 2000
Resolved 11 September 2000
Electrical
Issued 2 May 2000 Resolved
Prove operation of seized embarkation lighting, make operable by hand, portand stbd boat decks. SOLAS 74 III/19.2
Condition: Unknown
Due 11 September 2000
Resolved 11 September 2000
Lifesaving
Issued 2 May 2000 Resolved
Ring buoys on port boat deck & C deck (stern, stbd side) shall not be fitted with line & waterlight. Relocate line or waterlight to another buoy.SOLAS 74 III/7
Condition: Unknown
Due 11 September 2000
Resolved 11 September 2000
Fire Fighting
Issued 2 May 2000 Resolved
Provide key for the CO2 control panel located in the CO2 room. SOLAS 74 II-2/5
Condition: Unknown
Due 11 September 2000
Resolved 11 September 2000
Fire Fighting
Issued 2 May 2000 Resolved
In lieu of rubber hose, install a metallic shutoff valve at the air test connection to the engine room CO2 discharge piping located in the CO2 room.SOLAS 74 II-2/5
Condition: Unknown
Due 11 September 2000
Resolved 11 September 2000
Fire Fighting
Issued 2 May 2000 Resolved
Install door knob/latch assembly in the fire screen door located in the aftstairway, B deck. SOLAS 74 I/11
Condition: Unknown
Due 11 September 2000
Resolved 11 September 2000
Fire Fighting
Issued 2 May 2000 Resolved
Repair and prove closure of fire screen door, amidships stbd stairway entrance to A deck. SOLAS 74 I/11
Condition: Unknown
Due 11 September 2000
Resolved 11 September 2000
Construction/Loadline
Issued 2 May 2000 Resolved
Prove proper operation of the sliding watertight door in the manual and power modes of operation, tank top car deck. SOLAS 74 I/11
Condition: Unknown
Due 11 September 2000
Resolved 11 September 2000
Lifesaving
Issued 2 May 2000 Resolved
Prove proper operation of the steering gear on the stbd lifeboat. SOLAS 74 III/19.2
Condition: Unknown
Due 11 September 2000
Resolved 11 September 2000

Ownership record