RED OAK VICTORY

RED OAK VICTORY is a 1944 freight ship. The Coast Guard has recorded 24 inspections since 2016, most recently in February 2026, along with 28 deficiencies — 1 with no resolution recorded — and 3 operational controls, 1 with no removal date recorded.

Records from 2016 to 2026. Most recent: inspection, 20 February 2026.

Built
1944
Last inspected
20 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
1 with no removal date recorded

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 February 2026
Operational controls 1 with no removal date recorded
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

5291331
Flag
UNITED STATES
Maury page id
psix-63104

Documentation record

Registered dimensions (L × B × D)439.1 ft × 62.1 ft × 34.5 ft
Registered tonnagegross 7,640 / net 4,602
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTHE PERMANTS METALS CORP · RICHMOND, CA, UNITED STATES · built 1944
Hull materialSteel
PropulsionSteam Turbine
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portRICHMOND, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 January 2026 · expires 31 January 2027
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7640 - Regulatory (Subpart C or D), Gross Ton
4602 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

24 inspections, each with its date, unit and type; 28 deficiencies with the resolution recorded against each; 3 operational controls with the dates imposed and removed; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 24

20 February 2026 Administrative Inspection · Vessel Attendance
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8313506
25 September 2025 Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8235579
5 November 2024 Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8029459
12 September 2024 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7997649
28 September 2023 Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7787869
5 December 2022 Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7604299
18 October 2022 Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7579596
13 September 2021 COI Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7311329
14 September 2020 COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7057442
28 August 2020 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7044383
26 August 2019 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6795494
30 August 2018 Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6524147
10 July 2018 In-Service Inspection
Physical examination · Commandant (CG-5P-TI) · Activity 6601523
9 July 2018 In-Service Inspection · Administrative Inspection · ISM SMC Audit · Excursion Permit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6478623
13 June 2018 Administrative Inspection · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6443720
3 November 2017 Administrative Inspection
Administrative · Commandant (CG-5P-TI) · Activity 6320250
30 August 2017 Attraction Vessel Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6255704
4 April 2017 Periodic Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6118155
5 December 2016 Plan Review (Other than "T")
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6052566
22 November 2016 Internal Structural Exam · Drydock Extension · Plan Review (Other than "T")
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6034216
12 August 2016 Attraction Vessel Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6064070
9 August 2016 Excursion Permit
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5973248
21 June 2016 Excursion Permit
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5914388
1 March 2016 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5824903

Deficiency record · 28

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 September 2025 Resolved
The COFR Operator of a vessel must establish and maintain (or cause to be established and maintained) evidence of financial responsibility acceptable to the Director… Vessel is missing COFR. 33 CFR 138.40
Condition: Improper/Lack of Maintenance
Action required: 703 - Prior to bunkering operations
Due 9 October 2025
Resolved 31 March 2026
Resolution: Verified vessel has valid COFR.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 25 September 2025 Resolved
On a merchant vessel of the United States the construction of which began after March 4th, 1915..(5) each crew berthing area shall be equipped with information regarding-(A) vessel owner or company policies prohibiting sexual assault and sexual harassment, retaliation, and drug and alcohol usage; and (B) procedures and resources to report crimes, including sexual assault and sexual harassment, including information-(i) on the telephone number, website address, and email address for reporting allegations of sexual assault and sexual harassment to the Coast Guard;(ii) on vessel owner or company procedures to report violations of company policy and access resources; (iii) on resources provided by outside organizations such as sexual assault hotlines and counseling;(iv) on the retention period for surveillance video recording after an incident of sexual harassment or sexual assault is reported; and (v) additional items specified in regulations issued by, and at the discretion of, the Secretary of the department in which the Coast Guard is operating. (d) In each washing space in a visible location there shall be information regarding procedures and resources to report crimes upon the vessel, including sexual assault and sexual harassment, and vessel owner or company policies prohibiting sexual assault and sexual harassment, retaliation, and drug and alcohol usage. Vessel missing required signage in crew berthing areas. 46 U.S.C. 11011(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2025
Resolved 9 October 2025
Resolution: Posted signage.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 25 September 2025 Resolved
The purpose of this part is to ensure a dependable, independent, and dedicated emergency power source with sufficient capacity to supply those services that are necessary for the safety of the passengers, crew, and other persons in an emergency. Emergency light/exit sign on the stbd side museum is inoperable. 46 CFR 112.05-1(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2025
Resolved 9 October 2025
Resolution: Completed repair.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 25 September 2025 Resolved
Suitable hand covers, guards, or rails shall be installed in way of all exposed and dangerous places… Deck is wasted on stbd side of the flying bridge. Close off space to passengers until repairs are made. 46 CFR 92.25-15
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2025
Resolved 19 February 2026
Resolution: Completed repair.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 25 September 2025 Resolved
(a) In General.-The owner of a vessel subject to inspection under section 3301 shall- (1) ensure that such vessel is equipped with a vessel master key control system, manual or electronic, which provides controlled access to all copies of the vessel's master key of which access shall only be available to the individuals described in paragraph (2); (2) establish a list of all crew, identified by position, allowed to access and use the master key and maintain such list upon the vessel, within owner records and included in the vessel safety management system; (3) record in a log book information on all access and use of the vessel's master key, including- (A) dates and times of access;(B) the room or location accessed; and (C) the name and rank of the crew member that used the master key; and(4) make the list under paragraph (2) and the log book under paragraph (3) available upon request to any agent of the Federal Bureau of Investigation, any member of the Coast Guard, and any law enforcement officer performing official duties in the course and scope of an investigation. Vessel missing required key control.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 October 2025
Resolved 9 October 2025
Resolution: Provided SMS update.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 28 September 2023 No resolution recorded
Existing structure previously approved will be considered satisfactory so long as it is maintained in good condition to the satisfaction of the Officer in Charge, Marine Inspection. Minor repairs and alterations may be made to the same standard as the original construction. Vessel was found to have 20+ holes in the side shell below the deepest loaded waterline. Temporary, unapproved repairs, were attempted by the crew. Make permanent repairs to the satisfaction of the OCMI prior to movement. 46 CFR 92.01-90
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 28 September 2023 Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked as follows: (a) Spaces storing carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. VENTILATE THE AREA BEFORE ENTERING. A HIGH CONCENTRATION CAN OCCUR IN THIS AREA AND CAN CAUSE SUFFOCATION.”. (b) Spaces protected by carbon dioxide—“CARBON DIOXIDE GAS CAN CAUSE INJURY OR DEATH. WHEN ALARM OPERATES OR WINTERGREEN SCENT IS DETECTED, DO NOT ENTER UNTIL VENTILATED. LOCK OUT SYSTEM WHEN SERVICING.” The reference to wintergreen scent may be omitted for carbon dioxide systems not required to have odorizing units and not equipped with such units. Paint locker was found to not have required signage. Affix signage in all appropriate areas. 46 CFR 97.37-11
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 October 2023
Resolved 14 December 2023
Resolution: Signage confirmed in place.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 28 September 2023 Resolved
Under the authority if 46 U.S.C. 3313 and 46 U.S.C. 3710, a certificate of inspection issued to a vessel may be suspended or revoked if a vessel is found not to comply with the terms of its certificate or fails to meet a standard required by this chapter. During the COI renewal inspection, Marine Inspector found that the vessel was not complying with all the terms listed on the COI. The vessel is required to comply with its own operations manual and the terms listed on the COI. The following are required by the manual and are were not being completed by the crew: Man Overboard and Abandon ship drills that are required monthly were not being conducted. Specific crewmembers and staff are required to be certified in CPR and First Aid by Red Cross or equivalent. None of the crew/staff were current. USCG Approved life-rings are required to on board at locations listed on COI, but the life-rings were damaged and beyond service life. COI requires USCG approved portable fire extinguishers, but two were found not in their required brackets. Make corrections to the satisfaction of the attending Marine Inspector within 30 days. 46 CFR 2.01-20
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2023
Resolved 14 December 2023
Resolution: All sat.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 20 October 2022 Resolved
It shall be the duty of the owner, master, or person in charge to see that the vessel's firefighting equipment is at all times ready for use and that all such equipment required by the regulations in this subchapter is provided, maintained, and replaced as indicated. Four required portable extinguishers onboard had servicing tags showing they were overdue for inspection as of Aug. 2022.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2022
Resolved 4 November 2022
Resolution: Operator provided photos of updated inspection tags.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 18 October 2022 Resolved
Except as noted in this subpart or subpart 91.05, no vessel subject to inspection and certification shall be operated without a valid certificate of inspection. Vessel's COI expired on 05OCT2022 and passengers were carried after this date.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 October 2022
Resolved 27 October 2022
Resolution: Vessel completed inspection.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 18 October 2022 Resolved
Where natural ventilation is provided for spaces protected by carbon dioxide extinguishing system, provisions shall be made for easily and effectively closing off the ventilation. Paint locker on starboard forward main deck has CO2 protection with no way to secure natural ventilation pipe.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2022
Resolved 28 October 2022
Resolution: Crew provided photos for ventilation closure devices.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 October 2021 Resolved
Fire pumps, hydrants, hose and nozzles shall be installed on all self-propelled vessels. Numerous fire station cutout valves appear to be seized in the closed position. Prove proper operation of each fire station cutout supply valve. 46CFR95.05-5(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 18 October 2022
Resolution: Inspectors verified correction.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 October 2021 Resolved
Fires axes shall be distributed throughout the spaces available to persons on board so as to be most readily available in the event of emergency. Fire axes were discovered to be ziptied to there brackets making them not readily available. Remove the zipties on all fire axes. 46CFR95.60-10
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 20 October 2022
Resolution: Verified removal of zip ties.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 5 October 2021 Resolved
Where natural ventilation is provided for spaces protected by a carbon dioxide extinguishing system, provisions shall be made for easily and effectively closing off the ventilation. The emergency diesel generator ventilation closure was missing the required gasket. Install gasket to make closure air tight. 46CFR95.15-35
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 18 October 2022
Resolution: Verified installation of gasket.
01 - Certificates & Documentation › 011 - Ships Certificates › Civil Liability for Oil Pollution Damage Cert.
Issued 5 October 2021 Resolved
Any vessel using the navigable waters of the United States or any port subject to the jurisdiction of the United States must have a Certificate of Financial Responsibility. Vessel's COFR was expired. Renew COFR. 33CFR138.15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2021
Resolved 20 October 2022
Resolution: Verified vessel has valid COFR.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 September 2020 Resolved
All firehose must be subjected to a test pressure equivalent to the maximum pressure to which they may be subjected in service, but not less than 100 psi. Fire hoses were not ready for hydrostatic test. Complete hydro test in presence of CG within 30 days. 46 CFR 91.25-20(a)(4)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2020
Resolved 13 October 2020
Resolution: Witnessed all hoses pressed up.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 June 2020 Resolved
At each inspection for certification and at other times necessary, the inspector will determine that all fire-extinguishing equipment is in suitable condition. Annual servicing is overdue for all required portable and fixed fire fighting onboard. Conduct proper servicing and provide local OCMI with documentation for all overdue fire fighting equipment prior to allowing passengers onboard. 46 CFR 91.25-20
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2020
Resolved 28 August 2020
Resolution: Servicing records provided.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 June 2020 Resolved
All dead-end lines shall extend at least 2 inches beyond the last orifice and shall be closed with cap or plug. CO2 piping in port and starboard paint lockers do not extend 2 inches at dead-end. Storage of flammable materials prohibited in both paint lockers until proper piping installed. 46 CFR 95.15-15(e)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2020
Resolved 28 August 2020
Resolution: Photos provided for piping extension in both paint lockers.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 June 2020 Resolved
Complete but simple instructions for the operation of the systems must be located in a conspicuous place at or near all pull boxes, stop valve controls and in the cylinder storage room. No instructions provided for operation of CO2 protecting paint lockers. Post instructions for operation of paint locker CO2 system. 46 CFR 95.15-10(h)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 July 2020
Resolved 28 August 2020
Resolution: Photos provided for instructions posted outside both paint lockers.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 August 2019 Resolved
ISE was due 30NOV18. Complete ISE within 30 days.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2019
Resolved 5 December 2019
Resolution: Completed ISE
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 August 2019 Resolved
Fire hoses were not ready for hydrostatic test. Complete hydro test in presence of CG within 30 days.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 September 2019
Resolved 5 December 2019
Resolution: Witnessed sat hose test.
04 - Emergency Systems › N/A - No Subsystem › Safe areas
Issued 27 August 2019 Resolved
Install emergency escape/exit signage at the end of shaft alley within 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2019
Resolved 5 December 2019
Resolution: Crew installed proper signage.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 27 August 2019 Resolved
Rope off area to restrict passenger access on stack deck in engine room where insufficient rails protection is in place within 30 days.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 August 2019
Resolved 5 December 2019
Resolution: Crew secured areas.
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 30 August 2018 Resolved
Submit proposal to improve rails in boiler room flats intended to be accessible to passengers, install within 60 days of plan approval. Prevent passenger access to the identified areas until cleared.
Action required: 705 - Other - as specified
Resolved 18 January 2019
Resolution: Railings now satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 August 2018 Resolved
Provide (1) new 50ft fire hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 November 2018
Resolution: (2) new hoses provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Civil Liability for Oil Pollution Damage Cert.
Issued 30 August 2018 Resolved
Provide federal COFR.
Action required: 703 - Prior to bunkering operations
Resolved 29 November 2018
Resolution: Valid COFR provided.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 30 August 2018 Resolved
Provide transfer procedures.
Action required: 703 - Prior to bunkering operations
Resolved 22 January 2019
Resolution: Transfer procedures provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 August 2018 Resolved
Lock electric panel on bridge.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 September 2018
Resolution: Panel locked.