MAURY USCG vessel records
← All vessels

TASMANIA

TASMANIA is a 2001 freight ship. The Coast Guard has recorded 2 inspections since 2016, most recently in December 2017, along with 3 deficiencies.

Records from 2016 to 2017. Most recent: inspection, 26 December 2017.

Built
2001
Last inspected
26 December 2017
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 December 2017
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2016–2017)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9219434
9V3956
631586
Flag
ITALY
Maury page id
psix-631586

Documentation record

Tonnage as PSIX records it39713 - Convention (Subpart B), Gross Ton
24867 - Convention (Subpart B), Net Ton
75410 - Dead Weight, Metric Ton
85838 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 2

26 December 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6323121
12 February 2016 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5814153

Deficiency record · 3

Operations/Management › Drills/Instruction › Fire
Issued 26 December 2017 Resolved
2020-Fire drills-Fire drills should be planned insuch a way that due consideration is given to regular practice in the various emergencies that may occur depending on the type of ships and the cargo. PSCO observed that the last three (03) fire drills took place in the galley. When asked to perform drill in galley, crew was not able to perform drill adequately. 74SOLAS14 III/19.3.5.1. 17a.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 December 2017
Resolution: Classification society provided documentation attesting to training conducted with officers and crew on proper fire drill procedures.
Operations/Management › Drills/Instruction › Fire
Issued 26 December 2017 Resolved
2020-Fire drills-Each fire drill shall include checking of fireman's outfit and other personal rescue equipment. PSCO ran fire drills twice and firemans' outfits were not checked prior to fireman entering the drill. Fireman sent into the drill with the mask on and no air and there were manufacturer's stickers inhibiting the view from each face mask. 74SOLAS14 III/19.3.5.2.3, 17a.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 December 2017
Resolution: Classification society reported training was conducted to ensure future drills will be carried out in a satisfactory manner.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 26 December 2017 Resolved
2099-Other (SOLAS operational Def.)-Where "A" class divisions are penetrated for the passage of pipes, arrangements shall be made to ensure that the fire resistance is not impaired. PSCO observed sewage and gray water hoses passing from the engine room to the steering gear room, where emergency fire pump is located, propping doors open and negating A-60 boundary. 74SOLAS01 II-2/18.1.1, 10c.
Action required: 705 - Other - as specified
Due 26 December 2017
Resolved 26 December 2017
Resolution: Crew routed hoses alternately from the sewage discharge on the main deck the aft peak tank. This allowed doors between the engine room and the emergency fire pump space to properly close.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.