Records from 2003 to 2011. Most recent: operational control imposed, 17 September 2011.
Documentation record
Tonnage as PSIX records it25063 - Convention (Subpart B), Gross Ton
25063 - Simplified, Gross Ton
10189 - Simplified, Net Ton
10189 - Convention (Subpart B), Net Ton
43826 - Displacement, Ton
35000 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Inspection history · 20
14 September 2011
COC-CHEM Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4144860
26 July 2011
COE-Dockside
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4089554
15 March 2010
COE-Dockside
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3696100
25 June 2007
Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination · COC-CHEM Renew · MARPOL Annex V Examination · MARPOL Annex II Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2973242
20 April 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2629803
13 March 2006
Ballast Water Examination · ISPS II Exam · NPV Safety Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2601336
6 January 2006
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2562319
4 November 2005
Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 2536252
3 November 2005
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2527715
19 October 2005
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2518443
18 October 2005
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2516465
14 October 2005
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2514409
14 October 2005
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2514582
1 October 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2507496
30 September 2005
ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2504947
1 December 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2254094
19 September 2004
Special
Type not classified · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 2199248
13 September 2004
COC-CHEM Annual · Ballast Water Examination · ISPS II Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2194350
26 June 2004
ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2111196
3 July 2003
Certificate of Compliance · Ballast Water Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1832357
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 14 September 2011
Resolved
Oil tankers of 150 GT and above shall be equipped with an ODME and control system. System could not be proven to work properly. MARPOL Annex 1 Reg. 31.1 (70a)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 October 2011
Resolution: Received report from class attesting to the proper operation of the ODME.
Deck/Cargo › Vapor Control Systems › Liquid Overfill Protection
Issued 14 September 2011
Resolved
Each tankship vapor collection system must be fitted with a pressure sensing device that alarms visual and audible. Audible alarm did not occur during test of system. 46CFR39.20-13(b)(1) (17a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 September 2011
Resolution: Wiring was repaired reconnecting the audible alarms for the HIGH/LOW vapor pressure sensor. Class reports were recieved and found satisfactory.
Deck/Cargo › Holds/Tanks › Portable Gas Measuring Equipment
Issued 14 September 2011
Resolved
All tankers shall be equipped with at least one portable instrument for measuring flammable vapor concentrations, together with a sufficient set of spares. One of two portable gas detection instruments was properly calibrated. There was no suitable back up unit. SOLAS 74 (2001 Con.) II-2 Reg.59.5 (17a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 September 2011
Resolution: Recieved new unit and or Calibration of old units. Vessel now has two working portable gas detection devices and meets Solas Requirements.