MAURY USCG vessel records Sign in
← All vessels

WESTWARD

WESTWARD is a school ship. The Coast Guard has recorded 15 inspections since 2003, most recently in January 2010, along with 14 deficiencies and 1 casualty investigation in 2008.

Records from 2003 to 2010. Most recent: inspection, 11 January 2010.

Built
Not recorded
Last inspected
11 January 2010
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7730484 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDB4655
631774
Flag
UNITED STATES
366900860 (licence lapsed)
Maury page id
psix-631774

Inspections, by type

…with no type recorded2
Years with a record 7 calendar years (2003–2010)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the School Ship class in Maury's sources begin in 1981.

Documentation record

Registered dimensions (L × B × D)89.1 ft × 22.0 ft × 14.0 ft
Registered tonnagegross 114 / net 34
ITC dimensions (L × B × D)89.1 ft × 22.0 ft × 14.0 ft
ITC tonnagegross 114 / net 34
BuilderNot recorded
Hull materialSteel
PropulsionAuxiliary Sail
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPORTLAND, ME
Trade endorsementsCoastwise, restricted, Recreational, Registry
DocumentationValid · issued 7 February 2026 · expires 31 March 2027
Service, as the file records itSchool Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it114 - Convention (Subpart B), Gross Ton
34 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDB4655MMSI 366900860 · expired · voluntarily equipped · granted 9 July 2003, cancelled 14 September 2013
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 15

11 January 2010 DAPI Audit · Examination of Repairs · Annual Inspection · MARPOL Annex VI Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3661915
9 September 2008 Internal Structural Exam · Drydock Exam · COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3320824
6 August 2008 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3290856
26 April 2008 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3195220
30 October 2007 Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3084834
4 September 2007 Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3036194
26 August 2006 Hull Examination · Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2761734
21 April 2006 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2630323
20 April 2006 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2628992
29 September 2005 Administrative Inspection
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2504271
20 September 2005 Re-Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2492127
14 June 2005 Administrative Inspection
Administrative · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 2389931
13 June 2005 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2388849
1 September 2004 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2183048
8 August 2003 Hull Examination · COI Inspection
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1880726

Deficiency record · 14

Electrical › Lighting (emergency) › Lighting Fixture
Issued 30 October 2007 Resolved
Emergency lighting was replaced with temporary battery powered switch operated flashlights. Emergency lighting system must be repaired. Temporary battery operated emergency lights must be maintained in a working condition until repairs are complete.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 15 November 2007
Resolution: Cleared by Sector Charleston SC ([name withheld]/PO Hendricksen).
Fire Fighting › Fire Pumps › Pressure
Issued 30 October 2007 Resolved
Discharge pressure gauge on the main fire pump is inoperative. Provide a new pressure gauge for fire pump.
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 15 November 2007
Resolution: Cleared by Sector Charleston SC ([name withheld]/PO Hendricksen).
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 30 October 2007 Resolved
Paint locker aboard vessel must have fixed CO2 fire extinguishing system. Vessel must provide a fixed system or equivalent arrangement for the paint locker.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 November 2007
Resolved 19 December 2007
Resolution: Satisfactory installation of fixed 15 lb. CO2 system verified by [name withheld], Sector Charleston.
Electrical › Electric Supply System (service) › Battery Installation
Issued 30 October 2007 Resolved
Submit plans NLT 06Jun2008 to USCG Marine Safety Center to modify 120 volt large battery installation in engine room to meet the requirements of 46 CFR Subchapter J.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 June 2008
Resolved 11 August 2008
Resolution: MSC issued letter approving replacement of existing battery bank.
Electrical › Electric Supply System (service) › Battery Installation
Issued 30 October 2007 Resolved
Upon plan approval, complete modifications to 120 volt large battery installation NLT the next COI exam or 17Sep2008, whichever occurs first. Approval letter from MSC dated August 11, 2008 and placed in vessel hard file.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 January 2009
Resolved 13 May 2009
Resolution: Installed sealed battery bank as per written proposal dated 17 JUL 08 and MSC Approval letter dated 11 AUG 08 (MSC project #P014306). Power ventilation has been installed and meets the ventilation requirment for a moderate battery installation.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 29 September 2005 Resolved
REPLACE AND OR REPAIR ONE 20 PERSON LIFERAFT DAMAGED/INFLATED IN WX. VESSEL ROUTE RESTRICTED TO PARITALLY PROTECTED WATERS NOT GREATER THAN 20NM FROM A HARBOR OF SAFE REFUGE. TOTAL PERSON ON BOARD NOT MORE THAN 40. PRIMARY LS IAW 46CFR169.515. INSTALLATION / REPAIR SHALL BE TO THE SATISFACTION OF THE COGNIZANT [name withheld] 15OCT05.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 October 2005
Resolved 21 April 2006
Resolution: Liferaft was repacked and placed back aboard the vessel.
Electrical › Electrical Distribution System (service) › Cable
Issued 20 September 2005 Resolved
Remove permanently installed orange extension cord to lighting fixture in forward berthing area and engine room.
Action required: 705 - Other - as specified
Due 27 September 2005
Resolved 22 September 2005
Resolution: Wires removed
Stability › Watertight Integrity › General
Issued 20 September 2005 Resolved
Prove watertight integrity of galley and dry stores watertight doors.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 September 2005
Resolved 22 September 2005
Resolution: W/Tdoors repaired
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 20 September 2005 Resolved
Provide updated Coast Pilot and Light List
Action required: 705 - Other - as specified
Due 27 September 2005
Resolved 21 September 2005
Resolution: Provided on board
Operations/Management › Drills/Instruction › Not Conducted
Issued 1 September 2004 Resolved
Prior to carrying passengers, perform man overboard and fire drills in the presence of a marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2004
Resolved 22 September 2004
Resolution: Witnessed satisfactory underway man overboard and fire drills with crew.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 1 September 2004 Resolved
Prior to carrying passengers, make permanent repairs to after galley bulkhead in way of freezer flat and dry stores, to the satisfaction of the attendin marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2004
Resolved 14 September 2004
Resolution: Examined satisfactory temporary repair to bulkhead.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 1 September 2004 Resolved
Make permanent repairs to after galley bulkhead in way of freezer flat and dry stores, NLT next credit hull exam.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 August 2005
Resolved 21 June 2005
Resolution: Examined welded steel bulkhead insert. Witnessed satisfactory hose test.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 1 September 2004 Resolved
Make vessel machinery installations available for operational inspection by a marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2004
Resolved 22 September 2004
Resolution: Examined machinery installation while underway, and found them to be satisfactory.
Construction/Loadline › Hull
Issued 8 August 2003 Resolved
Four areas in vessel's hull structure were identified for repair and renewal. See narrative for further details. LEGACY COMPONENT DESC: Bottom Plating
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 September 2003

Casualty record · 1

26 April 2008Routine · role: Involved in a Marine Casualty · activity 3195220
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record