Records from 1992 to 2026. Most recent: inspection, 6 May 2026.
Documentation record
Registered dimensions (L × B × D)68.9 ft × 20.0 ft × 8.0 ft
Registered tonnagegross 93 / net 63
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPLATZER BOAT COMPANY · HOUSTON TX, UNITED STATES · built 1943
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSTURGEON BAY, WI
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 23 April 2026 · expires 31 May 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it93 - Regulatory (Subpart C or D), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 20
6 May 2026
Administrative Inspection · Deficiency Check · Annual Inspection · Vessel Attendance
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8377233
2 April 2025
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 8104208
11 July 2024
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7956104
26 July 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 7752825
15 June 2022
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7478271
11 April 2022
Deficiency Check · Initial Certification · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7440098
24 July 2018
Administrative Inspection
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6533262
8 May 2018
Administrative Inspection · Initial Certification
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 6409885
19 August 2016
Liferaft Servicing
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 5977077
16 July 2015
Type not recorded
No type recorded · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 5185966
16 July 2015
Type not recorded
No type recorded · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 5185976
1 July 2015
Type not recorded
No type recorded · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 5176459
17 November 2014
Industry Initiated Exam
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 5025356
1 November 2010
Industry Initiated Exam · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 4102270
24 February 2010
DAPI Audit
Administrative · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 3685596
27 April 2009
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3463663
29 September 1997
Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 779774
26 May 1993
Uninspected Towing Vessel
Physical examination · MIO STURGEON BAY · USCG Great Lakes District (CGD-GL) · Activity 1144020
31 July 1992
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 153568
31 July 1992
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 224023
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 6 May 2026
Resolved
Piping and machinery components that exceed 220 °C (428 °F), including fittings, flanges, valves, exhaust manifolds, and turbochargers, must be insulated.
No lagging was present on port and starboard engines turbochargers and lower exhaust. Install insulation on exterior of turbochargers and exhaust piping.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2026
Resolved 19 May 2026
Resolution: MI received objective evidence that lagging was installed
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 May 2026
Resolved
A fixed fire pump must be capable of: Delivering water simultaneously from the two highest hydrants at a pitot-tube pressure of at least 344 kilopascals (kPa) (50 pounds per square inch (psi)).
Gauge not present on fire pump line. MI not able to verify pressure requirement of at least 50 psi.
Install gauge allowing for verification of psi.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2026
Resolved 19 May 2026
Resolution: MI received objective evidence of operating pressure gauge
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 May 2026
Resolved
Each towing vessel must have a fire-detection system installed to detect engine room fires. The owner or managing operator must ensure the following: The design of the system and its installation on the towing vessel is certified and inspected by a registered professional engineer with experience in fire-detection system design.
Vessel could not provide paperwork from registered engineer verifying design and installation is certified and approved by registered professional engineer.
Submit proof submit attesting to such.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 May 2026
Resolved 19 May 2026
Resolution: MI recieved copy of PE letter for fire detection system
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 May 2026
Resolved
Each towing vessel must perform the applicable tests in Table 143.245(b) of this section. Essential systems, including emergency dewatering systems, must be tested once every 3 months.
No test record was available for inspection.
MI tested emergency dewatering systems. Corrected on spot.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 6 May 2026
Resolved 6 May 2026
Resolution: MI witnessed operation of bilge piping system
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 2 April 2025
Resolved
Flares on board were expired.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 April 2025
Resolved 29 April 2025
Resolution: Flares were renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 2 April 2025
Resolved
EPIRB hydrostatic release unit was expired.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 April 2025
Resolved 29 April 2025
Resolution: EPIRB hydro was renewed.
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 2 April 2025
Resolved
Depthsounder was inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 April 2025
Resolved 29 April 2025
Resolution: Depthsounder was working properly.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 2 April 2025
Resolved
Light for illuminated magnetic compass was not present.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 April 2025
Resolved 29 April 2025
Resolution: Magnetic compass light was working.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 2 April 2025
Resolved
Engine room bilge was full of oily water mixture.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 April 2025
Resolved 29 April 2025
Resolution: Engine room was clean and free from oil.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 April 2025
Resolved
Semi-portables in engine room were missed during fire servicing and are currently overdue.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 April 2025
Resolved 29 April 2025
Resolution: Semi-portable co2 bottles were serviced.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 2 April 2025
Resolved
Portable extinguisher in galley was stowed in the corner directly on the deck. Properly mount extinguisher in approved mounting device.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2025
Resolved 29 April 2025
Resolution: Fire extinguisher was properly mounted.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 April 2025
Resolved
Stern white light was inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2025
Resolved 29 April 2025
Resolution: Stern light was properly working.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 2 April 2025
Resolved
E-lighting or phosphorescent adhesive strips were not present in berthing area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2025
Resolved 29 April 2025
Resolution: Phosphorescent adhesive strips were in place to show egress.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 April 2025
Resolved
Flammable liquids stowed in engine room directly above main engine.
Action required: 17 - Rectify deficiencies prior to departure
Due 3 April 2025
Resolved 29 April 2025
Resolution: Flammable liquids were properly stowed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 July 2024
Resolved
The forward generator in the engine room is inoperable due to an oil leak. 46 CFR 143.205(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2024
Resolved 25 July 2024
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 11 July 2024
Resolved
The vessel has no means of notifying the aft operating station of an emergency. 46 CFR 143.230(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2024
Resolved 25 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 11 July 2024
Resolved
The immersion suits did not have lights attached to them. 46 CFR 141.350(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2024
Resolved 25 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 11 July 2024
Resolved
The hydrostatic release used for stowing the liferaft is expired. 46 CFR 141.310
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2024
Resolved 25 July 2024