MAURY USCG vessel records
← All vessels

HEROIC ACE

HEROIC ACE is a 2003 freight ship. The Coast Guard has recorded 14 inspections since 2016, most recently in June 2026, along with 4 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 12 June 2026.

Built
2003
Last inspected
12 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9252216
632128
Flag
PANAMA
Maury page id
psix-632128

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded1
Years with a record 8 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it56439 - Convention (Subpart B), Gross Ton
17959 - Convention (Subpart B), Net Ton
19879 - Dead Weight, Metric Ton
34528 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 14

12 June 2026 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8402716
13 April 2023 PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7667572
10 April 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7665538
6 December 2021 PSC A
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7361957
13 March 2021 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7151002
29 October 2020 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7085089
5 September 2020 PSC B
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7048831
22 January 2020 PSC B · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6890157
2 February 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6618989
29 January 2019 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6613976
3 May 2018 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6401237
15 September 2017 In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6265740
23 January 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6073323
19 January 2016 Deficiency Check · PII Safety Exam · Ballast Water Examination · Administrative Inspection · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5815288

Deficiency record · 4

09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 6 December 2021 Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PPSCO's witnessed fire/GS pump and #1 main cooling pumps leaking excessively.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2022
Resolved 10 April 2023
Resolution: Received C/E statement with pictures attesting satisfactory repairs to the pump gaskets, as well as Class NKK report attesting repairs were made.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 December 2021 Resolved
Cylinders must always be secured and, when not in use, they must be stowed in a rack in an upright position. PSCO's discovered 02 oxygen cylinders outside of the oxy/acetylene locker secured to a wall with ratchet straps.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2022
Resolved 10 April 2023
Resolution: Received bill of lading, report, and pictures attesting to removal of cylinders.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 January 2019 Resolved
THE CONDITION OF THE SHIP AND IT'S EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP WILL REMAIN FIT FOR SEA. IDENTIFIED 2 TEMP. REPAIRS FOR LEAKING BELOW CRANKCASE EXPLOSION COVERS ON MDE.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2019
Resolved 2 February 2019
Resolution: The class survey report outlined removal, cleaning, and replacement of gaskets on the #7 and #5 MDE crank case relief valves, resulting in proper seating of gaskets and closure of the identified leaks.
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 19 February 2016 Resolved
Starting arrangements for emergency generating sets shall have a second source of energy. When testing the hydraulic line parted rendering that system inoperable. 74 SOLAS(01) II-1/44.2 15ac
Condition: Design Flaw
Action required: 15 - Rectify deficiencies by next port
Due 19 February 2016
Resolved 19 February 2016
Resolution: Received a Classification report attesting to the repairs and proper operation on the secondary power supply to the emergency generator.