Records from 2016 to 2026. Most recent: inspection, 13 June 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 54
13 June 2026
In-Service Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8403457
13 June 2026
Type not recorded
No type recorded · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8404426
16 May 2026
PSC B · COC-CVE Quarterly
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8374242
21 November 2025
PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8262411
22 June 2025
PSC B · COC-CVE Quarterly
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8161772
22 December 2024
COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8048637
14 June 2024
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7934633
31 May 2024
PSC B · Deficiency Check · COC-CVE Quarterly
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7923431
21 December 2023
COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7840581
11 May 2023
PSC A · COC-CVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7685988
12 December 2022
Deficiency Check · COC-CVE Annual · PSC A · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7604255
25 April 2022
PSC A · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7433772
6 April 2020
In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6936059
22 January 2020
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6894165
26 November 2019
ISPS II Exam · Ballast Water Examination · COC-CVE Annual · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6863169
13 November 2019
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6855237
24 October 2019
Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6841039
25 September 2019
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6821086
17 September 2019
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6814021
13 September 2019
Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6811387
5 September 2019
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6805000
3 September 2019
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6802853
30 August 2019
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6799244
17 August 2019
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6835950
27 June 2019
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6728769
13 June 2019
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6719283
11 June 2019
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6724150
2 June 2019
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6700876
24 May 2019
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6698237
19 May 2019
COC-CVE Quarterly · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6673768
5 May 2019
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6679979
3 May 2019
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6680557
20 November 2018
ISPS III Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6581931
20 August 2018
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6564517
24 July 2018
Type not recorded
No type recorded · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6510713
9 July 2018
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6519198
29 June 2018
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6512210
28 May 2018
Type not recorded
No type recorded · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 6428177
11 May 2018
Ballast Water Examination · COC-CVE Quarterly · ISPS III Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6412220
11 November 2017
COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6301951
23 August 2017
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6250791
20 August 2017
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6269629
6 August 2017
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6275864
31 July 2017
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6257091
8 June 2017
COC-CVE Quarterly · Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6169673
16 November 2016
ISPS II Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6042707
28 October 2016
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6031463
10 September 2016
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6031357
10 August 2016
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5969687
10 August 2016
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5993496
18 June 2016
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5916665
1 June 2016
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5895735
23 May 2016
COC-CVE Quarterly · PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5884497
18 May 2016
Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5880432
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 13 June 2026
Resolved
Means shall be provided wherby normal operation of propulsion machinery can be sustained or restored even though one of the essential auxiliaries becomes inoperative. Special consideration shall be given to the malfunctioning of: a generating set which serves as a main source of electrical power. Ship reported a blackout and loss of propulsion. Repair and determine root cause to the satisfaction of classification society and USCG.
74 SOLAS II-I/26.3.1
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2026
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 May 2026
Resolved
Fire doors in main vertical zone bulkheads and stairways enclosures shall satisfy the following requirements: The doors shall be self-closing and be capable of closing against an angle of inclination of up to 35 degrees opposing closure.PSCO observed doors FSD 04.7.17 and FSD 04.2.03 unable to fully close.
74 SOLAS 01 II-2/30.4.1 17 c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2026
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 May 2026
Resolved
The construction of doors and door frames in 'A" class divisions, with the means of securing them when closed,shall provide resistance to fire as well as to the passage of
smoke and flame equivalent to that of the bulkheads in which
the doors are situated. PSCO observed FSD 12.6.01,12.3.01 and 11.5.01 did not fully latch.
74 SOLAS 20 II-2/9.4.1.1.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2026
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 16 May 2026
Resolved
Fire protection systems and fire-fighting systems and
appliances shall be maintained ready for use. PSCO observed trolley carts being stored in front of fire suppression cabinets fire station 06.III.03 and CO2 release system near FSD 06.02.10
74 SOLAS 20 II-2/14.1.1
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2026
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 16 May 2026
Resolved
Safe escape routes shall be provided. PSCO observed emergency exit doors on deck 15, stbd side pool deck, in a locked position and observed trash being stored at stairwell landing near emergency exit FSD 04.6.41.
SOLAS 20 II-2/13.1.1
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2026
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 16 May 2026
Resolved
For determining the appropriate fire integrity standards to
be applied to boundaries between adjacent spaces, such spaces are classified according to their fire risk as shown in
categories (1) to Spaces are classified according to their
fire risk as shown in categories (1) to (14). Lifeboat
mechanical station space inside FSD 07.6.03 is a category
(10) space where storage of combustibles is prohibited.
PSCO observed storage of cardboard boxes and other combustibles.
74 SOLAS 01 II-2/9.2.2.3.2.2
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2026
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 May 2026
Resolved
Doors and door frames in "B" class divisions and means of
securing them shall provide a method of closure which shall
have resistance to fire equivalent to that of the divisions. Two B15 fire doors IVO RM L704, one B15 IVO RM A503 and one
B15 next to room B504 did not fully latch.
74 SOLAS 20 II-2/9.4.1.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2026
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 16 May 2026
Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Deck
12 aft stairway guide unfamiliar with emergency duties.
Lifeboat 14, first in command, unfamiliar with operation of
lifeboat propulsion system. STBD fast rescue boat
technical crew unfamiliar with operation of rescue boat.
74 SOLAS 20 III/19.2.1
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 May 2026
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 21 November 2025
Resolved
Fire protection systems and fire-fighting systems and appliances shall be properly tested and inspected. PSCO observed broken portable fire extinguisher brackets 11-3-01, 11-3-04 and multiple throughout deck 11.
74 SOLAS 20 ii-2/14.1.2
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 December 2025
Resolved 1 December 2025
Resolution: Deficiency rectified to satisfaction of Coast Guard, as PSSC is not delegated to Class.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 22 December 2024
Resolved
The construction of all doors and door frames in "A" class divisions, with the means of securing them with closed shall provide resistance to fire as well as to the passage of smoke, as far as practicable, equivilant to that of the bulkheads in which the doors are situated. Such doors and frames shall be constructed of steel or other equivelant material. PSCO observed that the roller shutter was inoperable at the Salty Dog Cafe on deck 15.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 January 2025
Resolved 29 December 2024
Resolution: Vessel submitted pictures of rolling shutter on the open and closed positions to clear deficiency.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 22 December 2024
Resolved
Within the perimeter of such stairways enclosures, only public toilet, lockers of non-combustible mater providing storage for non-hazardous safety equipment and open information counters are permitter. PSCO observed sorage of items at bottom of crew stairwell between FSD 04.5.18 and FSD 04.5.17.
Action required: 10 - Deficiency Rectified
Due 22 December 2024
Resolved 22 December 2024
Resolution: Removed improperly stored items.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 22 December 2024
Resolved
Where the contents and use of a spae are such that there is a doubt as to its classification for the purpoer of this regulation, it shall be treated as a space within the relevent catagory haveing the most stringent boundary requiremnt. PSCO observes that A/C Station 15-15.4 is a Cat 10 space. Carboard was stored in that location.
Action required: 10 - Deficiency Rectified
Due 22 December 2024
Resolved 22 December 2024
Resolution: Cardboard was relocated to proper storage area.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 31 May 2024
Resolved
The machinery and associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. The #3 main diesel generator jacket water treatment system was actively leaking onto the smoke/heat detector #52-30 rendering it inoperable.
74SOLAS04II-1/26.1
74SOLAS(2004 CONS.) II-1/26.1
16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2024
Resolved 14 June 2024
Resolution: Tightened loose connection on jack water treatment system and replaced smoke detector. All in full working order. See attached report.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 31 May 2024
Resolved
Associated piping systems and fittings shall be of a design construction adequate for the service for which they are intended. PSCO observed the gray water transfer pump actively leaking indicating a failure of 02 valve stems, additionaly PSCO observed a pinhole leak in the reduction flange located between the 02 valve stems. 74SOLAS01II-1/26.1
74SOLAS(2004CONS.) II-1/26.1
16ac
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2024
Resolved 14 June 2024
Resolution: Delivery pipe fabricated and installed, and pump tested for leaks. Please see attached class report.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 31 May 2024
Resolved
The construction of all doors and door frames in "A" class divisions, with the means of securing them when closed, shall provide resistance to the fire as well as to the passage of smoke and flame, as far as practicable, equivalent to that of the bulkheads in which the doors are situated. Fire screen doors #11.2.14, 11.3.02 and 14.6.03 did not self-close. 74SOLAS01/II-2/30.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 31 May 2024
Resolution: PSCO verified fire door repairs to the satisfaction of the CG prior to departing the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 11 May 2023
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. Boiler feed line had water flowing out of flange connection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2023
Resolved 23 May 2023
Resolution: Vessel provided satisfactory report of repair.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 11 May 2023
Resolved
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. Smoke detector 04-047 was inoperable when tested and was tied in place by plastic zip-ties.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 June 2023
Resolved 23 May 2023
Resolution: Vessel provided satisfactory report of repair.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 12 December 2022
Resolved
74 SOLAS 04 II-1/15.7.1.5: Each power operated sliding door shall be provided with controls for opening and closing the door by power form both sides of the door and also for closing the door by power from the cntral operating console at the navigation bridge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2022
Resolved 20 January 2023
Resolution: all sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 September 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or personson board. The computer read a low lube oil pressure level on the pedestaql bearings on the port propulsion motor, which caused an automatic shut down of the propulsion motor.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2019
Resolved 24 October 2019
Resolution: Resolved via class report
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 19 May 2019
Resolved
Retro-reflective materials should be fitted on the outside of the boat as near the gunwale as possible. The outboard retro-reflective tape on several lifeboats including 8,10, and 14 on the outside of the boat near the gunwale is deteriorated. 74 SOLAS (01) III/34, LSA 1.2.2.7, IMO Res A.685(16)/1.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2019
Resolved 2 June 2019
Resolution: New retro tape instlalled.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 May 2019
Resolved
Furniture in stairway enclosures shall be limited to seating. Tables were installed for hotel staff on deck. - 74 SOLAS (01) II-2/34.6.
Action required: 10 - Deficiency Rectified
Resolved 19 May 2019
Resolution: Tables removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 May 2019
Resolved
Piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons onboard. The potable water ppiping in the forward pump room on deck 1 is deteriorated and spraying water onto electrical distibution panels. - 74 SOLAS (01) II-1/26.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2019
Resolved 2 June 2019
Resolution: Wasted section of pipe cropped and renewed.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 11 May 2018
Resolved
0999 - Other (Safety in General) - Means of escape shall be marked at all points of the escape route and must enable passengers to identify all routes of escape and readily identify the escape exits. Across from cabin A705 the low location lighting does not readily identify the means of escape at the door. - 74 SOLAS (01) Ch. II-2/28.1.5.10 - 10c
Action required: 10 - Deficiency Rectified
Resolved 11 May 2018
Resolution: Photoluminescent tape installed leading to door handle.
Accommodation/Occupational Safety › Potable Water System › General
Issued 16 November 2016
Resolved
Multiple Soft Patches were found on copper piping throughout the ship.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 November 2016
Resolved 5 December 2016
Fire Fighting › Means of Escape › Corridors
Issued 16 November 2016
Resolved
The passenger escape route goes through the backstage area than immediately exits into stage area which is a passenger muster area.
Condition: Design Flaw
Due 16 May 2017
Resolved 10 June 2017
Resolution: Cabin egress instructions do not route the passengers through the backstage area.