Records from 2003 to 2008. Most recent: inspection, 5 June 2008.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 7
5 June 2008
Administrative Inspection · Simplified Stability Test
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3228158
22 May 2008
Hull Examination · Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3213342
8 June 2007
Re-Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3124741
18 May 2006
Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2836872
1 June 2005
Re-Inspection
Physical examination · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 2375811
2 June 2004
Annual Inspection
Physical examination · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 2099303
9 July 2003
COI Inspection · Initial Construction-Excluding Oversight
Physical examination · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 1841806
Communications › Visual Communication › Warning Sign (radio room)
Issued 22 May 2008
Resolved
Post Emergency Broadcast placard.
Condition: Unknown
Due 3 July 2008
Resolved 3 June 2009
Resolution: Placard posted.
Construction/Loadline › Structures › Door
Issued 22 May 2008
Resolved
Plexiglass in emparkation gate cracked.
Condition: Damaged By Earlier Event
Due 3 July 2008
Resolved 3 June 2009
Resolution: Gate plexiglass repaired/replaced.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 22 May 2008
Resolved
Remove unauthorized life vest.
Condition: Unknown
Due 3 June 2008
Resolved 3 June 2008
Resolution: Removed
Electrical › Electric Supply System (service) › Battery Installation
Issued 22 May 2008
Resolved
Battery terminal loose.
Condition: Unknown
Due 3 June 2008
Resolved 3 June 2008
Resolution: Cleaned and tightened.
Fire Fighting › Ventilation Systems › Fans
Issued 2 June 2004
Resolved
Replace screen on stern with approved flame screen. LEGACY COMPONENT DESC: Ducts
Condition: Improper Installation
Due 2 August 2004
Resolved 6 June 2005
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 9 July 2003
Resolved
Mark all lifejackets with vessels name.
Condition: Improper Installation
Due 30 August 2003
Resolved 6 June 2005
Engineering › Fuel Oil Service System › Valve
Issued 9 July 2003
Resolved
Install reach rod for emergency fuel shut-off valve so it is accessible from deck. LEGACY COMPONENT DESC: Valve, Control
Condition: Improper Installation
Due 30 August 2003
Resolved 6 June 2005
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 9 July 2003
Resolved
Mark ring buoy with vessel name.
Condition: Placed in Improper Service
Due 30 August 2003
Resolved 6 June 2005
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 9 July 2003
Resolved
Mark ring buoy with Type I I Retro-reflective tape spaced evenly on both sides of buoy with 2x4 inch tape.
Condition: Improper Installation
Due 30 August 2003
Resolved 6 June 2005
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 9 July 2003
Resolved
Mark life jacket storage with number of lifejackets stowed.
Condition: Unknown
Due 30 August 2003
Resolved 6 June 2005