JEFFERSON is a 1947 passenger vessel (uninspected). The Coast Guard has recorded 19 inspections since 2004, most recently in July 2012, along with 13 deficiencies and 1 casualty investigation in 2009.

Records from 2004 to 2012. Most recent: inspection, 5 July 2012.

Built
1947
Last inspected
5 July 2012
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD2443
634411
Flag
UNITED STATES
367115390 (licence lapsed)
Maury page id
psix-634411

Inspections, by type

…with no type recorded4
Years with a record 7 calendar years (2004–2012)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)74.0 ft × 19.2 ft × 9.4 ft
Registered tonnagegross 74 / net 33
ITC dimensions (L × B × D)74.0 ft × 19.2 ft × 9.4 ft
ITC tonnagegross 74 / net 33
BuilderDE VOORVITGADE GOWSLIUS · ALPHEN, HOLLAND, NETHERLANDS · built 1947
Hull materialSteel
PropulsionAuxiliary Sail
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPORTSMOUTH, VA
Trade endorsementsRecreational
DocumentationValid · issued 31 October 2025 · expires 31 October 2028
Service, as the file records itPassenger (Uninspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it74 - Convention (Subpart B), Gross Ton
33 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD2443MMSI 367115390 · expired · voluntarily equipped · granted 12 April 2016, cancelled 27 June 2026
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 19

5 July 2012 Attraction Vessel Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4381886
25 May 2012 Attraction Vessel Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4314843
10 September 2010 Attraction Vessel Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3851331
4 May 2009 Attraction Vessel Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3447235
21 November 2008 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3367450
12 October 2006 Attraction Vessel Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2799019
18 August 2006 Attraction Vessel Exam
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2752164
15 August 2006 Attraction Vessel Exam
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2748363
4 August 2006 Attraction Vessel Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2744419
13 July 2006 Attraction Vessel Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 2712268
6 July 2006 Attraction Vessel Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2703791
19 September 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2496211
17 August 2005 Uninspected Other
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2466086
17 August 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2473567
16 August 2005 Type not recorded
No type recorded · Station Sandy Hook · USCG Northeast District (CGD-NE) · Activity 2465899
9 September 2004 Attraction Vessel Exam
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2191408
17 June 2004 In-Service Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2101824
10 June 2004 In-Service Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2094759
11 February 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2004430

Deficiency record · 13

Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 17 August 2005 Resolved
Make proper repairs to MDE exhause leak in E/R
Action required: 705 - Other - as specified
Resolved 26 August 2005
Resolution: Exhaust leak was repaired.
Engineering › Generator (propulsion/auxiliary-electric) › Wiring
Issued 17 August 2005 Resolved
Install air filter on 12 KW generator.
Action required: 705 - Other - as specified
Resolved 26 August 2005
Resolution: Air filter installed.
Engineering › Fuel Oil Service System › Filter
Issued 17 August 2005 Resolved
Install shield/arrester for fuel filter IWO day tank and MDE.
Action required: 705 - Other - as specified
Resolved 26 August 2005
Resolution: Shield arrester for fuel filter installed.
Engineering › Freshwater Generation System › Piping
Issued 17 August 2005 Resolved
Properly mount water (fresh) cylinder.
Action required: 705 - Other - as specified
Resolved 26 August 2005
Resolution: Cylinder mounted properly.
Electrical › Electrical Distribution System (service) › Cable
Issued 17 August 2005 Resolved
Remove plastic tie wraps in E/R and install metal supports for cables every 24 inches.
Action required: 705 - Other - as specified
Resolved 26 August 2005
Resolution: Tie wraps removed, and metal supports installed.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 17 August 2005 Resolved
Provide documentation for licensed master.
Action required: 705 - Other - as specified
Resolved 26 August 2005
Resolution: Documentation provided for licensed master.
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 17 August 2005 Resolved
Repair leak at manual fuel pump.
Action required: 705 - Other - as specified
Resolved 26 August 2005
Resolution: Leak repaired.
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 17 August 2005 Resolved
Repair splice at fuel transfer pump.
Action required: 705 - Other - as specified
Resolved 26 August 2005
Resolution: Splice repaired.
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 17 August 2005 Resolved
Install pressure gauge at LPG cylinder as required by ABYC A-1 regulations.
Action required: 705 - Other - as specified
Resolved 3 October 2005
Resolution: Pressure gauge installed.
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 17 August 2005 Resolved
Install junction box in LPG storage locker.
Action required: 705 - Other - as specified
Resolved 3 October 2005
Resolution: Junction box installed.
Documentation › Markings/Placards › Warning Signs
Issued 17 August 2005 Resolved
Install/post "caution" sign as noted in ABYC A-1 regulations.
Action required: 705 - Other - as specified
Resolved 3 October 2005
Resolution: Sign posted.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 9 September 2004 Resolved
Do not operat any machinery until fixed CO2 system all portable extinguisers are inspected/tested.
Action required: 705 - Other - as specified
Resolved 13 September 2004
Fire Fighting › Fire Hoses › Condition
Issued 9 September 2004 Resolved
Replace Fire hose prior to passengers onboard.
Action required: 705 - Other - as specified
Resolved 9 September 2004

Casualty record · 1

5 August 2009Routine · role: Reported in distress · activity 3561856
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

STV UNICORN (2009). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record