EVAGORAS

EVAGORAS is a 2003 tank ship. The Coast Guard has recorded 7 inspections since 2017, most recently in March 2022, along with 5 deficiencies and 2 operational controls.

Records from 2017 to 2022. Most recent: inspection, 24 March 2022.

Built
2003
Last inspected
24 March 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 March 2022
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2017–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9239484
634497
Flag
LIBERIA
Maury page id
psix-634497

Documentation record

Tonnage as PSIX records it84789 - Convention (Subpart B), Gross Ton
53755 - Convention (Subpart B), Net Ton
165209 - Dead Weight, Ton
189187 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 7

24 March 2022 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7417684
5 December 2021 PSC B · Administrative Inspection · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7359372
30 November 2021 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7359422
30 November 2021 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7359769
30 November 2021 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7359821
20 February 2017 COE-Dockside
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6083879
16 January 2017 Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6068905

Deficiency record · 5

07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 5 December 2021 Resolved
Inert Gas System- The system shall be capable of delivering inert gas with an oxygen content of not more than 5% by volume to the cargo tanks at any required rate of flow. PSCO spent over two hours waiting for the crew to show proficiency and ability to reduce the oxygen content below 5%. Crew must demonstrate full system capabilities including ability to maintain output of less than 5% oxygen content, and proper shutdowns and alarms. Rectify deficiency prior to conducting any/all cargo operations. 74 SOLAS (04) II-2/5.5.1.1- FSS Code 15.2.2.1.2.5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2021
Resolution: Received class report with proper documentation supporting complete IG system functionality.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 December 2021 Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect including those on board tankers unless the Administration is satisfied that such equipment is appropriate to the space concerned. On the #2 cargo oil pump, two temperature sensor housings were not properly installed with a gas-tight gland preventing accumulation of vapor in the housing. Lowest temperature sensor on #2 COP was not properly installed allowing it to be pulled straight out of the pump housing. Rectify deficiency prior to conducting cargo discharge operations. 74 SOLAS (04) II-1/45.10
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2021
Resolution: Received class report with proper documentation attesting to the fact that the temp sensors had been properly repaired.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 December 2021 Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect including those on board tankers unless the Administration is satisfied that such equipment is appropriate to the space concerned. 6 explosion proof lights on various decks of the Cargo Pump Room were found with cracked lenses. Rectify deficiency prior to conducting cargo discharge operations. 74 SOLAS (04) II-1/ 45.10
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2021
Resolution: Received class report with proper documentation attesting to the fact that the EX lights had been properly replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 December 2021 Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect including those on board tankers unless the Administration is satisfied that such equipment is appropriate to the space concerned. Lighting in the oxygen and acetylene stores were recently replaced and don't have a gas-tight packing gland where the wires enter the housing. 74 SOLAS (04) II-1/ 45.10
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2021
Resolution: Received class report with proper documentation attesting to the fact that the EX lights were properly seal IAW IEC.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 5 December 2021 Resolved
The company should establish procedures, plans, and instructions including checklists as appropriate, for key shipboard operations concerning the safety of the personnel, ship, and protection of the environment. Vessel crew demonstrated substantial unfamiliarity with the oxygen analyzer and how to accurately sample oxygen content in the produced inert gas. It took the entire engineering staff over two hours to demonstrate the system's ability to produce less than 5% oxygen. The crew had to remove the three sample lines in the inert gas supply main to verify which one was active. Erroneous sampling lines and valves from the replaced O2 analyzer resulted in further confusion. Lack of familiarity and systematic ineptitude resulted in the crew damaging filters and blocking sample lines. Require external audit to verify proper operational instructions are implemented and the crew is properly trained on how to operate the inert gas system. Recommend removing erroneous equipment and piping to reduce confusion and prevent future crews from improperly operating a vital cargo system. 74 SOLAS (20) IX/3.1 - ISM Code 7
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2021
Resolution: Received class report with proper documentation supporting crew has been properly trained and understands how to use thier system.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.