← All vessels
EVAGORAS
EVAGORAS is a 2003 tank ship. The Coast Guard has recorded 23 inspections since 2003, most recently in March 2022, along with 10 deficiencies and 8 operational controls.
Records from 2003 to 2022. Most recent: inspection, 24 March 2022.
- Built
- 2003
- Last inspected
- 24 March 2022
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 10 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9239484 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
D5VX8
634497
Flag
LIBERIA
—
Maury page id
psix-634497
Inspections, by type
…with no type recorded10
Years with a record
9 calendar years (2003–2022)
The 23 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it84789 - Convention (Subpart B), Gross Ton
53755 - Convention (Subpart B), Net Ton
165209 - Dead Weight, Ton
189187 - Displacement, Ton
53755 - Convention (Subpart B), Net Ton
165209 - Dead Weight, Ton
189187 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 23
24 March 2022
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7417684
5 December 2021
PSC B · Administrative Inspection · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7359372
30 November 2021
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7359422
30 November 2021
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7359769
30 November 2021
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7359821
20 February 2017
COE-Dockside
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6083879
16 January 2017
Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6068905
7 December 2011
COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4202553
2 October 2010
Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3861737
2 January 2006
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2559284
1 January 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2557110
26 October 2005
Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 2522651
21 May 2005
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2365257
2 January 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2268797
24 August 2004
ISPS II Exam · COC-TVE Annual
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2169901
6 April 2004
Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2038235
27 August 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1897406
31 July 2003
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1866054
31 July 2003
Control Verification
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1866064
25 July 2003
Certificate of Compliance
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1859278
24 July 2003
Security Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1869075
23 July 2003
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1859363
21 July 2003
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1859382
Deficiency record · 10
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 5 December 2021
Resolved
Inert Gas System- The system shall be capable of delivering inert gas with an oxygen content of not more than 5% by volume to the cargo tanks at any required rate of flow. PSCO spent over two hours waiting for the crew to show proficiency and ability to reduce the oxygen content below 5%. Crew must demonstrate full system capabilities including ability to maintain output of less than 5% oxygen content, and proper shutdowns and alarms. Rectify deficiency prior to conducting any/all cargo operations.
74 SOLAS (04) II-2/5.5.1.1- FSS Code 15.2.2.1.2.5
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 December 2021
Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect including those on board tankers unless the Administration is satisfied that such equipment is appropriate to the space concerned. On the #2 cargo oil pump, two temperature sensor housings were not properly installed with a gas-tight gland preventing accumulation of vapor in the housing. Lowest temperature sensor on #2 COP was not properly installed allowing it to be pulled straight out of the pump housing. Rectify deficiency prior to conducting cargo discharge operations.
74 SOLAS (04) II-1/45.10
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 December 2021
Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect including those on board tankers unless the Administration is satisfied that such equipment is appropriate to the space concerned. 6 explosion proof lights on various decks of the Cargo Pump Room were found with cracked lenses. Rectify deficiency prior to conducting cargo discharge operations.
74 SOLAS (04) II-1/ 45.10
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 5 December 2021
Resolved
No electrical equipment shall be installed in any space where flammable mixtures are liable to collect including those on board tankers unless the Administration is satisfied that such equipment is appropriate to the space concerned. Lighting in the oxygen and acetylene stores were recently replaced and don't have a gas-tight packing gland where the wires enter the housing.
74 SOLAS (04) II-1/ 45.10
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 5 December 2021
Resolved
The company should establish procedures, plans, and instructions including checklists as appropriate, for key shipboard operations concerning the safety of the personnel, ship, and protection of the environment. Vessel crew demonstrated substantial unfamiliarity with the oxygen analyzer and how to accurately sample oxygen content in the produced inert gas. It took the entire engineering staff over two hours to demonstrate the system's ability to produce less than 5% oxygen. The crew had to remove the three sample lines in the inert gas supply main to verify which one was active. Erroneous sampling lines and valves from the replaced O2 analyzer resulted in further confusion. Lack of familiarity and systematic ineptitude resulted in the crew damaging filters and blocking sample lines. Require external audit to verify proper operational instructions are implemented and the crew is properly trained on how to operate the inert gas system.
Recommend removing erroneous equipment and piping to reduce confusion and prevent future crews from improperly operating a vital cargo system.
74 SOLAS (20) IX/3.1 - ISM Code 7
Engineering › Steam System (main) › Piping
Issued 7 December 2011
Resolved
1499 - Prop & Aux Machinery - No change shall be made in the machinery, equipment, or other items covered by the survey without the sanction of the administration. The vessel has temporary feedwater hoses running from the port freshwater tank to the boiler system cascade tank. 74SOLAS (2009 ConsEd I/11 (b).
Engineering › Diesel Engine (propulsion-direct drive) › Pump, High Pressure (fuel injection)
Issued 7 December 2011
Resolved
0999 - Safety in General - Means shall be provided to control leaks of flammable liquids. The main engine #3 fuel pump is leaking oil. 74 SOLAS (2004 ConsEd) II-2/4.1.1.
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 7 December 2011
Resolved
0999 - Safety in General - SCBA shall hold a volume of at least 1200 liters. 02 of the vessel's SCBAs leaked out within minutes of opening. 74 SOLAS (2004 ConsEd) II-2/10.1. FSS Code 3.2.1.2.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 2 January 2006
Resolved
Vessel has inop discharge valve from OWS. Vessel is to make satsifactory repairs and provide proof of proper operation of OWS to the satisfaction of the certificate issuing authority. Report must be received prior to departure
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 31 July 2003
Resolved
Gyro control box sending weak signals to repeaters, rendering them inop or unreliable. Tech attended vessel while in port, and unable to permantly correct. Parts required from overseas.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.