Records from 2016 to 2026. Most recent: inspection, 1 May 2026.
Inspection history · 51
1 May 2026
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8439906
12 February 2026
PSC B · COC-CVE Quarterly
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8309677
20 October 2025
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8292137
18 August 2025
PSC A · COC-CVE Annual
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8210058
27 July 2025
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8196360
25 April 2025
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8142203
17 February 2025
COC-CVE Quarterly · PSC B
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8079636
19 August 2024
COC-CVE Annual · PSC A
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7983814
25 February 2024
PSC B · COC-CVE Quarterly
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7867255
20 August 2023
PSC A · COC-CVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7771332
26 February 2023
COC-CVE Quarterly · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7639047
20 December 2022
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7611546
28 August 2022
COC-CVE Annual · PSC A
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7541009
30 July 2022
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7520567
24 July 2022
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7514841
16 May 2022
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7471337
9 May 2022
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7446664
14 March 2022
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7411259
5 March 2022
COC-CVE Quarterly · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7403427
10 September 2021
COC-CVE Annual · PSC A
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7298247
18 April 2020
In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6940808
15 April 2020
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6939592
31 March 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6933843
9 March 2020
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7054579
22 December 2019
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6877874
17 November 2019
COC-CVE Quarterly · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6854639
18 October 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6837483
13 October 2019
In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6834484
11 October 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6860169
12 September 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6830047
18 August 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6798030
19 May 2019
Ballast Water Examination · COC-CVE Annual · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6682800
18 April 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6665150
17 November 2018
Ballast Water Examination · COC-CVE Quarterly · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6581834
23 October 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6566723
2 June 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6450282
2 June 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6452410
19 May 2018
ISPS III Exam · COC-CVE Annual · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6416071
17 May 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6417029
5 May 2018
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6407833
21 April 2018
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6396211
8 April 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6395519
13 November 2017
Ballast Water Examination · ISPS II Exam · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6305967
14 October 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6288674
30 July 2017
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6275398
20 May 2017
ISPS II Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6148473
29 April 2017
In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6136089
26 November 2016
ISPS II Exam · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6043692
5 October 2016
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6036648
24 September 2016
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6012391
12 May 2016
Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5875147
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 16 February 2026
Resolved
Auxillary machinery spaces which do not contain machinery having a pressure lubrication system and where storage of combustibles is prohibited. PSCO observed combustible materials being stored within AC station 7.9
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 March 2026
Resolved 16 February 2026
Resolution: Crew removed materials from space.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 August 2025
Resolved
07105 Openings shall be provided with permanently attached means of closing which shall be at least effective for resisting fires as the divisions in which they are fitted. PSCO observed door FSD 0.087 leading to the garbage room not properly latching. 74 SOLAS 01 II-2/30.1 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 August 2025
Resolved 18 August 2025
Resolution: FSD was restored to its proper operational condition.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 August 2025
Resolved
07106 The activation of any detector or manually operated call point (MCP) shall initiate a visual and audible fire signal at the control panel and indicating units. If the signals have not recieved attention within 2 min an audible alarm shall be automatically sounded throughout the crew accommodation and service spaces, control stations and machinery spaces of category A. PSCO observed the MCP not operating with a key or glass activation. 74 SOLAS 01 II-2/13.1.4 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 August 2025
Resolved 18 August 2025
Resolution: MCP was fixed and alarm/activation was operating properly.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 August 2025
Resolved
07120 Stairways and ladders shall be arranged to provide ready means of escape to the lifeboat and liferaft embarkation deck from all passenger and crew spaces and from spaces in which the crew is normally employed, other than machinery spaces. PSCO observed three rolls of matting obstructing the restricted yellow marked path in the electrical locker FSD 0.066. 74 SOLAS 01 II-2/28.1 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 August 2025
Resolved 18 August 2025
Resolution: Matting was removed clearing the path of the FSD.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 19 August 2024
Resolved
Fire doors in main vertical zone bulkheads, galley boundries and stairway enclosures, the approximate time of closure for hinged fire doors shall be no more than 40 s and no less than 10 s from the beginning of their movement. Fire Screen Door 9.051 and MVZ2 Fire Screen Doors 9.040 and 9.042 in the galley on Deck 9 did not close.
74 SOLAS 01 II-2/30.4.2
10 c.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 August 2024
Resolved 19 August 2024
Resolution: Doors were adjusted by crew. CG witnessed proper closure multiple times while on scene.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 26 February 2023
Resolved
All life-saving appliances and arrangements shall comply with the applicable requirements of the Code. The engine shall be provided with either a manual starting system, or a power starting system with two independent rechargeable energy sources. Crew could not start lifeboat #15 due to loose battery connection. Battery correctly reconnected. 74SOLAS20/III-34 LSA Code 4.4.6.2 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 26 February 2023
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 26 February 2023
Resolved
Passenger ships of 500GT and over shall carry at least one rescue boat on each side of the ship. Rescue boat #1 steering system was unable to operate from the steering position due to low hydraulic oil level. Crew added oil to correct level. 74SOLAS20/III-2.2.1 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 26 February 2023
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 March 2022
Resolved
A door designed to reopen upon contacting with an object in its path shall reopen not more than 1 m from the point of contact. PSCO observed sliding fire screen door FSD 5.026 and FSD 2.018 to open more than the prescribed 1 m from the point of contact. 74 SOLAS (2001) II-2/30.4.11 - 16ac
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 March 2022
Resolved 9 March 2022
Resolution: Received class report from LR stating the deficiency was verified and corrected.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 March 2022
Resolved
Above the bulkhead deck there shall be at least two means of escape from each main vertical zone or similarly restricted space or group of spaces at least one of which shall give access to a stairway forming a vertical escape. PSCO observed emergency escape pathway blocked by wood furniture in the vicinity of corridor 6 on deck 0.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 5 March 2022
Resolved 5 March 2022
Resolution: Crew removed the furniture that blocked the escape route.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 10 September 2021
Resolved
Ventilation ducts shall be provided with suitable located hatches for inspection and cleaning. In the launderette located across the passageway from fire station 9.12, the fwd dryer's cleaning hatch was seized and unable to be opened. The aft dryer's exhaust duct was excessively dirty. 74 SOLAS (2001) II-2/32.1.8 - 16 a c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2021
Resolved 13 September 2021
Resolution: Received and accepted class report from LR clearing deficiency.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 September 2021
Resolved
Sprinklers shall be placed in an overhead position and spaced in a suitable pattern to maintain an average application. PSCO observed high fog distribution line capped in place of a sprinkler head at the base of stairwell DK A, Stairs 30, WTC 19, MVFZ 1. 74 SOLAS (2001) II-2/12.3 - 50 a c
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 October 2021
Resolved 13 September 2021
Resolution: Received and accepted class report from LR clearing deficiency.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 22 December 2019
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. AFTER ALLISION, VESSEL SUFFERED SIGNIFICANT DAMAGE TO AFT DECKS 3,4 DINING ROOM.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 December 2019
Resolution: PSC NOLA RECEIVED CLASS REPORT ATTESTING TO THE SEAWORTHINESS OF VESSEL. DAMAGE STILL EXISTS AND WILL BE CONTINUALLY REPAIRED PER CLASS/FLAG APPROVAL.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 November 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Aft stairwell between decks 4 and 3 has broken welds a the bottom stair allowing the staircase to move and be structurally unfit. 74 SOLAS (2014) I/11a 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 November 2019
Resolved 17 November 2019
Resolution: Ships crew welded the staircase to the deck.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 November 2019
Resolved
Fire doors and main vertical zone bulkheads shall satisfy the following requirements: The doors shall be self closing. FSD 3.084 is not capable of latching closed. 74 SOLAS (2001) II-2/0.4.1 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 November 2019
Resolved 17 November 2019
Resolution: Ships crew adjusted door satisfactorily.
Lifesaving › Rescue Boat › Hull (rigid)
Issued 21 April 2018
Resolved
THE RESCUE BOAT EMBARKATION AND LAUNCHING ARANGEMENTS SHALL BE SUCH THAT THE RESCUE BOAT CAN BE BOARDED AND LAUNCHED WITHIN THE SHORTEST POSSIBLE TIME. RESCUE/LIFEBOAT #2 SUSTAINED DAMAGE TO THE HULL WHEN FWD MASTER LINK PARTED. THE BOAT DROPPED ONTO THE RAILING ON THE DECK BELOW. BOAT HAS BEEN REMOVED FROM SERVICE AND CLASS WILL ISSUE SHORT-TERM PSSC DESIGNATING AN ALTERNATE RESCUE BOAT.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2018
Resolved 5 May 2018
Resolution: Life boat was repaired by PALIFINGER on 02MAY2018. The hull was repaired and the chain links replaced. Class attended the vessel and reissued all documents that were ammended for the deficiency. See attached class report to MISLE # 64078333.
Electrical › Electric Generation Source (emergency) › Circuit Breaker
Issued 29 April 2017
Resolved
Where the emergency source of electrical power is a generator, it shall be started automatically upon failure of electrical supply from the main source of electrical power. Vessel emergency diesel generator does not start automatically upon failure of electrical supply from main source of electrical power. 74 SOLAS (04) II-1/42.3.1.2
Action required: 705 - Other - as specified
Due 13 May 2017
Resolved 8 May 2017