MAURY USCG vessel records Sign in
← All vessels

ATLANTICAT

ATLANTICAT is a 2003 passenger vessel (inspected). The Coast Guard has recorded 69 inspections since 2003, most recently in May 2026, along with 101 deficiencies, 2 operational controls and 15 casualty investigations between 2004 and 2018.

Records from 2003 to 2026. Most recent: inspection, 28 May 2026.

Built
2003
Last inspected
28 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9283069 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDG9892
635555
Flag
UNITED STATES
367592230
Maury page id
psix-635555

Inspections, by type

…with no type recorded16
Years with a record 20 calendar years (2003–2026)
The 69 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)116.5 ft × 35.9 ft × 13.0 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)116.5 ft × 35.9 ft × 13.0 ft
ITC tonnagegross 471 / net 175
BuilderBLOUNT BARKER LLC · WARREN, RI, UNITED STATES · built 2003
Hull materialAluminum
PropulsionJet Drive
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPORTSMOUTH, NH
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it471 - Convention (Subpart B), Gross Ton
99 - Regulatory (Subpart C or D), Gross Ton
175 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP6507MMSI 367592230 · active · compulsorily equipped · granted 13 June 2024, expires 13 June 2034
WDG9892MMSI 367592230 · expired · compulsorily equipped · granted 19 October 2013, cancelled 23 December 2023
WDB5455MMSI 366909810 · expired · compulsorily equipped · granted 16 October 2003, cancelled 22 December 2013
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 69

28 May 2026 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8382117
22 May 2026 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8353481
26 June 2025 MTSA Verification · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8168599
10 April 2025 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 8106461
11 June 2024 Annual Inspection · Administrative Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7936814
6 June 2023 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7759174
14 April 2023 Drydock Exam · Deficiency Check · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7670391
1 October 2020 Administrative Inspection · Deficiency Check · In-Service Inspection · Drydock Exam · Deadweight Survey · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7090411
9 January 2020 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6898571
6 January 2020 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6883148
22 October 2019 DAPI Audit
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6841065
8 October 2019 In-Service Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6832392
31 July 2019 Damage Survey
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6768941
22 July 2019 Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6758528
6 May 2019 Examination of Repairs · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6670921
15 November 2018 In-Service Inspection · DAPI Audit · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6578133
19 August 2018 Examination of Repairs
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6517478
21 June 2018 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6455404
16 June 2018 Damage Survey
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6449271
28 May 2018 COI Inspection · MTSA Verification · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6423757
26 January 2018 Examination of Repairs
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6405850
6 October 2017 Examination of Repairs · Damage Survey · Plan Review (Other than "T") · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6282809
6 October 2017 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6311082
29 June 2017 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6296025
20 June 2017 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6181863
5 December 2016 Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6052604
17 August 2016 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5975445
21 August 2015 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5207748
25 July 2012 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 4391439
21 June 2012 Examination of Repairs
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 4360754
26 August 2011 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 4127721
29 November 2010 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3900131
1 September 2010 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3840522
4 December 2009 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3644599
17 July 2009 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3543087
3 July 2009 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3543084
1 May 2009 Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3465146
25 February 2009 Examination of Repairs
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3424313
8 December 2008 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3376259
11 August 2008 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3295535
23 July 2008 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 3278526
9 June 2008 Hull Examination · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3232856
28 May 2008 COI Inspection · MTSA Verification
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3206957
5 May 2008 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3201602
25 September 2007 MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3062851
19 June 2007 Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3021553
27 March 2007 Deficiency Check · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2896081
15 September 2006 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2778469
12 September 2006 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2799099
1 July 2006 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 2797198
2 March 2006 Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2594558
26 August 2005 MTSA Verification · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2475117
29 April 2005 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2345655
24 March 2005 Examination of Repairs
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2319261
18 October 2004 Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2222888
13 October 2004 Internal Structural Exam · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2209577
16 September 2004 Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2197565
1 April 2004 In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2035625
24 March 2004 Type not recorded
No type recorded · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 2032293
24 March 2004 Examination of Repairs · Damage Survey · Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 2035632
2 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1957551
18 November 2003 Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1939316
29 October 2003 Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1951348
29 October 2003 Damage Survey
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1964834
16 October 2003 Type not recorded
No type recorded · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1935059
14 October 2003 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1924471
14 October 2003 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2031745
5 August 2003 Deficiency Check
Physical examination · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 1867122
17 July 2003 Construction Oversight · Deadweight Survey · Hull Examination · Internal Structural Exam · Initial Certification
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1849270

Deficiency record · 101

05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 26 June 2025 Resolved
Replace expired HRU on EPIRB. Vessel restricted to not more than 3 miles from land until corrected.
Action required: 705 - Other - as specified
Due 26 July 2025
Resolved 27 June 2025
Resolution: New HRU installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 June 2025 Resolved
Replace expired chem lights on PFDs. Passenger count while on Oceans route restricted to # of PFDs onboard with unexpired lights. Otherwise, vessel restricted to LCW route.
Action required: 705 - Other - as specified
Due 26 July 2025
Resolved 27 June 2025
Resolution: New lights installed.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 26 June 2025 Resolved
Repair/Replace flashlight in engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2025
Resolved 10 July 2025
Resolution: New light inservice.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 11 June 2024 Resolved
FCC station certificate expired, renew certificate.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2024
Resolved 20 June 2024
Resolution: New certificate on vessel 06/13/2024 to expire 06/13/2034.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 June 2024 Resolved
#10 portable extinguisher missed annual inspection, obtain either new extinguisher or service.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2024
Resolved 20 June 2024
Resolution: Extinguisher annual service completed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 June 2023 Resolved
Two 50 man life rafts out for service, reduction of passengers by 100 pax until rafts are back on vessel.
Action required: 705 - Other - as specified
Due 6 June 2023
Resolved 15 June 2023
Resolution: Rafts installed on vessel and restrictions lifted for pax carriage.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 November 2021 Resolved
Hull plating under stbd engine room battery box holed due to corrosion.. Insert needed.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2022
Resolution: Reapirs complete.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 November 2021 Resolved
Internal framing in both engine rooms IWO the turn of the bilge needs to be inserted due to wastage. Insert frames as needed to repair to new.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2022
Resolution: Repairs complete.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 18 November 2021 Resolved
Aft heads, main deck, port and stbd decking plate is wasted. Insert as needed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2022
Resolution: Repairs complete.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 November 2021 Resolved
Hull weld seam holed port side hull inboard. Insert as needed.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2022
Resolution: Repairs complete.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 18 November 2021 Resolved
Deck plating aft under the stern compartment ventilation trunks is holed on th eport and stbd sides. Insert as needed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2022
Resolution: Repairs complete.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 November 2021 Resolved
Hull plate holed under sewage tank stbd hull. Insert as needed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 June 2022
Resolution: Repair complete.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 8 October 2019 Resolved
Bottom plating in starboard A/C void is pitted. Repair to original scantling, pitted hull plating (bottom) in way of frs. 20 to 21, starboard hull. Operator shall conduct daily checks of void space and log results prior to conducting passenger operations. Operator shall conduct weekly operational checks of the installed high water alarm and log results. Any change to the condition of the void space shall be reported to the nearest Coast Guard Inspection Office.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2020
Resolved 22 August 2022
Resolution: area was inserted during DD/ISE completed 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 August 2019 Resolved
Provide spanner wrench on F.S. #1.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2019
Resolved 5 September 2019
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 22 August 2019 Resolved
Prove comms on installed phones (galley and port jet room).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2019
Resolved 13 September 2019
Resolution: New system installed.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 22 August 2019 Resolved
Install cover (properly seal) on black water tank in port jet room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 September 2019
Resolved 5 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 22 August 2019 Resolved
Prove proper operation of gear oil and engine oil pressure gages on bridge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2019
Resolved 13 November 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 August 2019 Resolved
Install pipe support on saltwater pump piping in starboard jet room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2019
Resolved 5 September 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 August 2019 Resolved
Properly install AC controller covers in stabd AC room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2019
Resolved 5 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 August 2019 Resolved
Replace Turbo rings/seals as necessary to address exhaust leaks.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2019
Resolved 13 November 2019
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 August 2019 Resolved
Install new cover on bridge AC outlet (starboard side).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2019
Resolved 5 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 August 2019 Resolved
Clean starting battery box and address oil fill/venting issue on #1 MDE.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 September 2019
Resolved 5 September 2019
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 22 August 2019 Resolved
Install automatic closure devices on fuel tanks.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2020
Resolved 22 August 2022
Resolution: Self closing valves were installed during DD 2022.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 July 2019 Resolved
Vessel lost #1 port engine due to turbo charger malfunction
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2019
Resolved 7 August 2019
Resolution: Vessel changed turbo and provided technician report.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 6 May 2019 Resolved
Make repairs to hole and crack in port side rub rail; make repairs to concave weld inboard starboard side as identified. 46CFR115.610
Action required: 705 - Other - as specified
Resolved 7 May 2019
Resolution: Inspected satisfactory weld repair.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Cylinder
Issued 16 June 2018 Resolved
Blown #3 cylinder on rt bank of forward starboard engine.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 June 2018
Resolved 28 June 2018
Resolution: Deficiency checked and cleared by the attending Marine Inspector.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 28 May 2018 Resolved
Provide FCC Safety Radio Certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2018
Resolved 6 July 2018
Communications › Radio Communications › VHF Radiotelephone
Issued 28 May 2018 Resolved
MMIS Number inputted in DSC radio is incorrect with issued number from FCC. Enter FCC assigned MMIS number into DSC radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2018
Resolved 6 July 2018
Electrical › Electric Supply System (service) › Battery Installation
Issued 28 May 2018 Resolved
Vital load battery's located in bridge are not covered or secured from movement. Provide covers to prevent accidental shorting of battery and secure from movement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2018
Resolved 25 June 2018
Electrical › Lighting (emergency) › Lighting Fixture
Issued 28 May 2018 Resolved
Prove operation of (03) emergency lights.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 June 2018
Stability › Unintentional Flooding › General
Issued 6 October 2017 Resolved
Vsl to make perm repairs to stbd sea chest piping with fractured weld.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 October 2017
Resolution: New pipe installed and tested sat.
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 21 June 2017 Resolved
Mount control unit in starboard jet room.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 10 July 2017
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 21 June 2017 Resolved
Repair hole in house exterior bulkhead IWO galley.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 10 July 2017
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 21 June 2017 Resolved
Replace expired waterlight battery.
Action required: 705 - Other - as specified
Due 24 June 2017
Resolved 22 June 2017
Resolution: Batteries replaced.
Electrical › Lighting (service) › Lighting Fixture
Issued 21 June 2017 Resolved
Prove operation of all exterior deck lighting.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 1 December 2017
Construction/Loadline › Structures › Ventilators
Issued 21 June 2017 Resolved
Replace port engine room vent cover/bezel.
Action required: 705 - Other - as specified
Due 22 July 2017
Resolved 1 December 2017
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 21 June 2017 Resolved
Post donning placards on fantail.
Action required: 705 - Other - as specified
Due 24 June 2017
Resolved 22 June 2017
Resolution: Placards are in place.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 31 August 2016 Resolved
Provide original COD onboard.
Due 30 September 2016
Resolved 29 September 2016
Resolution: Attended vessel. COD on board.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 31 August 2016 Resolved
Prove operation of upper and lower nav lights.
Due 30 September 2016
Resolved 29 September 2016
Resolution: Attended vessel. Nav lights tested sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 31 August 2016 Resolved
Provide local instructions for CO2 system.
Due 30 September 2016
Resolved 29 September 2016
Resolution: Attended vessel. CO2 local instructions are in place.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 31 August 2016 Resolved
ID and label breakers in all panels- update directories.
Due 30 September 2016
Resolved 29 September 2016
Resolution: Attended vessel. All breaker panels verified and labeled.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 31 August 2016 Resolved
Repair/Replace life jacket stowage aft (hinge)
Due 30 September 2016
Resolved 18 October 2016
Resolution: New box is ordered and will be installed upon arrival.
Communications › Alarms/Indicators › Fire Alarm
Issued 31 August 2016 Resolved
Provide approved fire detection system. System was updated with non-approved components. Vessel allowed to operater with current system until start of 2017 operating season.
Due 1 October 2017
Resolved 28 May 2018
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 1 September 2010 Resolved
PROVE PROPER OPERATION OF RIDE CONTROL IN AUTOMATICE MODE.
Action required: 705 - Other - as specified
Due 30 September 2010
Resolved 24 September 2010
Fire Fighting › Fire Main › Condition
Issued 1 September 2010 Resolved
PROVE PROPER OPERATION OF PORT AND STBD FIRE PUMPS PRIOR TO CARRYNG PASSENGERS.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 September 2010
Resolution: RECEIVED CALL FROM [name withheld] HAD BEEN MADE AND BOTH FIRE PUMPS HAD BEEN SATISFACTORILY TESTED.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 28 May 2008 Resolved
REPLACE AFT EXHAUST MOUNTING BOLTS (X4). TO BE COMPLETED AT NEXT DRYDOCK.
Action required: 705 - Other - as specified
Resolved 27 June 2008
Resolution: Repair made, digital photos of repair sent to MSD Fort Meyers
Navigation › Collision/Grounding Avoidance › Radar
Issued 25 September 2007 Resolved
PROVIDE TECHNICIANS REPORT ATTESTING TO THE REPAIR/PROPER OPERATION OF THE X BAND MARINE RADAR.
Action required: 705 - Other - as specified
Resolved 26 September 2007
Resolution: CLEARED
Engineering › Diesel Engine (auxiliary) › Distributor (fuel injection)
Issued 27 March 2007 Resolved
Make proper reairs to fuel leak in port side generator engine. The generator is not to be used with passengers onboard until repairs have been made.
Due 10 April 2007
Resolved 16 April 2007
Construction/Loadline › Hull › Hull Plating
Issued 7 November 2006 Resolved
Vessel is not to carry passengers until a credit drydock inspection is completed.
Action required: 705 - Other - as specified
Due 7 December 2006
Resolved 26 December 2006
Resolution: Drydock completed in Boston per phone conversation with [name withheld].
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 15 September 2006 Resolved
Provide placards that match quantities on board.
Action required: 705 - Other - as specified
Due 15 October 2006
Resolved 18 October 2006
Resolution: Attended vessel. Custom placards are on baord.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 15 September 2006 Resolved
Store and mark crew PFD's seperately from passengers.
Action required: 705 - Other - as specified
Due 15 October 2006
Resolved 18 October 2006
Resolution: Attended vessel. PFD''s stowed and marked seperately.
Electrical › Lighting (service) › Lighting Fixture
Issued 15 September 2006 Resolved
Install missing light to bare wire connectors in starboard aft main cabin.
Action required: 705 - Other - as specified
Due 15 October 2006
Resolved 18 October 2006
Resolution: Attended vessel. A light has been installed in that location.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 15 September 2006 Resolved
Prove proper operation of fwd port side door closure on deck.
Action required: 705 - Other - as specified
Due 15 October 2006
Resolved 26 December 2006
Resolution: Received call from [name withheld]. 835 cleared by MSO Boston.
Electrical › Lighting (service) › Switch
Issued 15 September 2006 Resolved
Provide switch plate cover for port tank void light.
Action required: 705 - Other - as specified
Due 15 October 2006
Resolved 18 October 2006
Resolution: Attended vessel. Light fixture renewed.
Electrical › Electric Generation Source (service) › Switch
Issued 15 September 2006 Resolved
Prove proper operation of port generator switch 400 amp panel (door will not close) and Provide non-conductive matting.
Action required: 705 - Other - as specified
Due 15 October 2006
Resolved 18 October 2006
Resolution: Attended vessel. New closure device installed.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 15 September 2006 Resolved
Remove oil from bilge IWO in both engine rooms.
Action required: 705 - Other - as specified
Due 15 October 2006
Resolved 18 October 2006
Resolution: Attended vessel. Bilges inspected and cleaned. Master has installed o-ring at dip stick to prevent further issues at that spot.
Communications › Alarms/Indicators › Bilge Alarm
Issued 15 September 2006 Resolved
Prove proper operation of both fore peak high bilge alarms.
Action required: 705 - Other - as specified
Due 15 October 2006
Resolved 18 October 2006
Resolution: Attended vessel. New switches installed. Both alarms tested satisfcatory.
Engineering › Steering Gear System › Ram Seal
Issued 15 September 2006 Resolved
Make repairs as necessary to cease water leakage from hycraulic steering actuators where protruding through hull.
Action required: 705 - Other - as specified
Due 15 October 2006
Resolved 26 December 2006
Resolution: Received call from [name withheld] of MSO Boston advising that 835 has been cleared.
Fire Fighting › Fixed Gas Fire Extinguishing System › Piping
Issued 15 September 2006 Resolved
Provide technican report attesting to the proper configuration and operation of the fixed fire fighting system after making proposed modifications.
Action required: 705 - Other - as specified
Due 15 October 2006
Resolved 20 November 2006
Resolution: Technican report dated 14NOV06 submitted.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 26 August 2005 Resolved
CONDUCT MONTHLY SAFETY GEAR INSPECTIONS INCLUDING EPIRB TEST AND LOG SAME; FAX COPY OF LOGBOOK ENTRIES FOR SEP, OCT, AND NOV 2005 TO MSD FT. MYERS.
Due 30 November 2005
Resolved 28 February 2006
Resolution: CLEARED
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 26 August 2005 Resolved
POST A PROPER EMERGENCY INSTRUCTION LIST THAT COMPLIES WITH 46CFR122.510.
Due 26 September 2005
Resolved 9 September 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 26 August 2005 Resolved
INSTALLED APPROVED SCREW TOP BATTERIES IN BOTH LIFE RING WATERLIGHTS.
Due 26 September 2005
Resolved 9 September 2005
Operations/Management › Drills/Instruction › Fire
Issued 26 August 2005 Resolved
CONDUCT EMERGENCY DRILLS UNDERWAY.
Action required: 705 - Other - as specified
Due 26 September 2005
Resolved 9 September 2005
Engineering › Non-conventional Propulsion/Steering › Steering Deflector (jet)
Issued 26 August 2005 Resolved
DEMONSTRATE MAIN PROPULSION SYSTEM UNDERWAY ALONG WITH GENSETS AND FIRE PUMPS.
Action required: 705 - Other - as specified
Due 26 September 2005
Resolved 9 September 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 24 March 2005 Resolved
Provide receipt showing repairs made to #3 engine.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 March 2005
Resolved 23 April 2005
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 24 March 2005 Resolved
Provide servicing report for FM-200 system for starboard engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 March 2005
Resolved 23 April 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 24 March 2005 Resolved
Provide written statement attesting to satisfactory sea trial of #3 engine.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 March 2005
Resolved 23 April 2005
Navigation › Piloting/Steering › Marine Charts
Issued 18 October 2004 Resolved
Provide charts indicating latest corrections per BNTM and Local Notice to Mariners.
Action required: 705 - Other - as specified
Due 18 November 2004
Resolved 18 November 2004
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 18 October 2004 Resolved
Provide up to date tide and current information.
Action required: 705 - Other - as specified
Due 18 November 2004
Resolved 18 November 2004
Navigation › Piloting/Steering › Coast Guard Light List
Issued 18 October 2004 Resolved
Provide current Coast Guard Light List.
Action required: 705 - Other - as specified
Due 18 November 2004
Resolved 18 November 2004
Documentation › Logs/Records › Drug Test Records
Issued 18 October 2004 Resolved
Provide evidence that MIS report was submitted for 2003.
Action required: 705 - Other - as specified
Due 18 November 2004
Resolved 18 November 2004
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 18 October 2004 Resolved
Provide evidence of EAP supervisor training.
Action required: 705 - Other - as specified
Due 18 November 2004
Resolved 18 November 2004
Personnel › Training › GMDSS
Issued 18 October 2004 Resolved
Demonstrate captain and first mate's competance with SSB/GMDSS.
Action required: 705 - Other - as specified
Due 18 November 2004
Resolved 18 November 2004
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 18 October 2004 Resolved
Stow loose cooking equipment in galley.
Action required: 705 - Other - as specified
Due 18 November 2004
Resolved 18 November 2004
Electrical › Electrical Distribution System (service) › Panelboard
Issued 18 October 2004 Resolved
Blank off openings in electrical panel marked "MN Lights and GPOS."
Action required: 705 - Other - as specified
Due 18 November 2004
Resolved 18 November 2004
Personnel › Training › Familiarization Training
Issued 18 October 2004 Resolved
Provide evidence of crew's completion of companies crew training program - provide copies of bridge log entries showing dates that crewmembers completed company's training program, provide entries for at least 2 Captains and 5 crewmen.
Action required: 705 - Other - as specified
Due 18 November 2004
Resolved 18 November 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 18 October 2004 Resolved
Provide service report for vessel's fire protection equipment.
Action required: 705 - Other - as specified
Due 18 November 2004
Resolved 18 November 2004
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 18 October 2004 Resolved
Test fire detection system in presence of USCG Marine Inspectors.
Action required: 705 - Other - as specified
Due 18 November 2004
Resolved 18 November 2004
Communications › Alarms/Indicators › Bilge Alarm
Issued 18 October 2004 Resolved
Test high water bilge alarm in presence of USCG Marine Inspector.
Action required: 705 - Other - as specified
Due 18 November 2004
Resolved 18 November 2004
Personnel › Training
Issued 1 April 2004 Resolved
VESSEL'S SPEED IS RESTRICTED TO LESS THAN 30 KNOTS UNTIL CREW TRAINING MANUAL IS SUBMITTED TO COGNIZANT [name withheld]: Manual
Action required: 705 - Other - as specified
Due 1 May 2004
Resolved 6 May 2004
Resolution: Training manual received.
Construction/Loadline › Structures
Issued 1 April 2004 Resolved
Required to re-submit plans to the MSC so the new structure can be re-evaluated to ensure the new design is adequate to operate safely in excess of 30kts. Operating speed is limited to not more than 30kts until MSC has re-evaluated the structure and provided guidance for safe operation. LEGACY COMPONENT DESC: Plans
Action required: 705 - Other - as specified
Due 16 April 2004
Resolved 28 April 2004
Resolution: Recieved email from MSC regarding the plan approval for new bulwark structure. [name withheld] approved the plans. Requirement cleared.
Construction/Loadline › Hull
Issued 1 April 2004 Resolved
Upon arrival in Ft. Myers and prior to carrying passengers, the vessel is to undergo inpsection of repairs by a qualified Marine Inspector from [name withheld] (MSD Ft. Myers). LEGACY COMPONENT DESC: Weld
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2004
Resolved 2 April 2004
Resolution: Inspected repairs and found two welds unsat, issued CG-835 to correct.
Construction/Loadline › Hull
Issued 1 April 2004 Resolved
Make proper repairs to all welds indicated by Marine Inspector. Repaired welds are not to be coated prior to inspection by a qualified Marine Inspector and vessel may not carry passengers until he welds have been inspected. LEGACY COMPONENT DESC: Weld
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 April 2004
Resolution: Inspected all welds, found two unsat, issued CG-835 to make proper repairs.
Construction/Loadline › Hull
Issued 1 April 2004 Resolved
Refit and properly weld stiffener on port side of forward gunwhale as marked, also complete weld on web frame starboard side as marked. LEGACY COMPONENT DESC: Weld
Action required: 705 - Other - as specified
Due 9 April 2004
Resolved 9 April 2004
Operations/Management
Issued 1 April 2004 Resolved
Vessel is not permitted to operate when significant wave heights are greater than 2.5 meters. Restriction to remain in effect until CG Marine Safety Center has re-evaluated structure and design in accordance with MSD Marathon's CG-835 issued 4/01/2004.
Action required: 705 - Other - as specified
Due 16 April 2004
Resolved 6 May 2004
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 29 October 2003 Resolved
Vessel to proceed to Ft. Myers, FL to determine the cause of accidental discharge and conduct satisfactory repairs of the same. Upon arrival in Ft. Myers vessel not to carry passengers until the repair of the above item is witnessed by Marine Inspector and cognizant OCMI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2003
Resolution: Corrected, witnessed sat recharge of system.
Fire Fighting › Combustible Materials
Issued 14 October 2003 Resolved
Remove plastic trash cans from vessel and replace with non-combustible cans. LEGACY COMPONENT DESC: Trash cans
Action required: 705 - Other - as specified
Due 28 October 2003
Resolved 18 November 2003
Stability › Watertight Integrity
Issued 14 October 2003 Resolved
Adjust automatic door closures on watertight doors throughout vessel to ensure proper closing. LEGACY COMPONENT DESC: Watertight doors
Action required: 705 - Other - as specified
Due 28 October 2003
Resolved 18 November 2003
Engineering › Sea-water System (primary cooling)
Issued 14 October 2003 Resolved
Properly support main engine cooling and all other overboard pipes. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Due 17 November 2003
Resolved 18 November 2003
Engineering › Sea-water System (primary cooling)
Issued 14 October 2003 Resolved
Properly repair #3 main engine cooling overboard pipe (w/temp repair) with permanent metallic pipe. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Due 17 November 2003
Resolved 18 November 2003
Documentation › Manuals/Policy Documentation › Bridge Resource Management Policy/Procedures
Issued 14 October 2003 Resolved
SUBMIT CREW TRAINING MANUAL PER TIME LINE PROVIDED IN KEY WEST FERRY, INC., LETTER TO US COAST GUARD MARINE SAFETY DETACHMENT FORT MYERS DATED 14 OCTOBER 2003. LEGACY COMPONENT DESC: CREW TRAINING MANUAL
Action required: 705 - Other - as specified
Due 30 January 2004
Resolved 18 November 2004
Documentation › Safety/Response Plans/Programs
Issued 9 October 2003 Resolved
Provide Operation Manual for vessel. LEGACY COMPONENT DESC: Vessel Operation Plan per NAVIC 5-01
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 October 2003
Resolved 14 October 2003
Resolution: Operations Manual was provided.
Documentation › Safety/Response Plans/Programs
Issued 9 October 2003 Resolved
Provide written proposal for acceptance by [name withheld] that describes company's training program required by 46 CFR Subchapter "K" and recommended by NAVIC 5-01. Proposal shall include milestones to be reached in development of training manual. LEGACY COMPONENT DESC: Crew Training Manual
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 October 2003
Resolved 14 October 2003
Resolution: Proposal submitted.
Electrical › Lighting (service)
Issued 17 July 2003 Resolved
Keyosk lighting fixtures and receptacles not installed. Branch circuit breakers tested, sat. Installation of fixtures to be completed prior to carriage of passengers. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 July 2003
Resolved 24 July 2003
Engineering › Non-conventional Propulsion/Steering
Issued 17 July 2003 Resolved
Replace temp duct work w/permanent installation, both port and starboard Jet rooms.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 July 2003
Resolved 24 July 2003
Electrical › Electrical Distribution System (service)
Issued 17 July 2003 Resolved
Install non-conducting matts and non conducting grab rail at each switch board / distribution panel to satisfaction of attending inspector. LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 July 2003
Resolved 24 July 2003
Electrical › Electrical Distribution System (service)
Issued 17 July 2003 Resolved
Label all breakers in all distribution panels IAW the distribution box diagrams. To satisfaction of attending inspector. LEGACY COMPONENT DESC: Panelboard
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 July 2003
Resolved 24 July 2003
Lifesaving › Embarkation Appliances/Stations
Issued 17 July 2003 Resolved
Mount/Post Emergency Evacuation plan/Fire Control plan on main/mid-deck. Plan reviewed approved. LEGACY COMPONENT DESC: Accessability
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 July 2003
Resolved 24 July 2003
Operations/Management › Equipment Service/Testing
Issued 17 July 2003 Resolved
Provide approved plans for hydraulics, air, passenger evacuation, and examined fireload calculations as built. Systems were inspected vs plans as submitted, sat.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 July 2003
Resolved 23 July 2003
Resolution: MSC approval rcvd.
Operations/Management › Drills/Instruction
Issued 17 July 2003 Resolved
Conduct New to Zone Inspection, Drills; manoverboard, fire, and emergency egress. To satisfaction of attending USCG Inspector. LEGACY COMPONENT DESC: Man Overboard Recovery
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 July 2003
Resolved 24 July 2003
Documentation › Manuals/Policy Documentation › Bridge Resource Management Policy/Procedures
Issued 17 July 2003 Resolved
Provide operations manual IAW NVIC 5-01 to address manning and ops for high speed vessel operations. LEGACY COMPONENT DESC: Bridge Resource Management Policy/Procedures
Action required: 705 - Other - as specified
Due 30 August 2003
Resolved 18 November 2004

Casualty record · 15

24 March 2004Routine · role: Involved in a Marine Casualty · activity 2032293
29 April 2005Routine · role: Involved in a Marine Casualty · activity 2345655
1 July 2006Routine · role: Involved in a Marine Casualty · activity 2797198
12 September 2006Routine · role: Involved in a Marine Casualty · activity 2799099
19 June 2007Routine · role: Involved in a Marine Casualty · activity 3021553
17 June 2009Routine · role: Involved in a Marine Casualty · activity 3506716
3 July 2009Routine · role: Involved in a Marine Casualty · activity 3543084
17 July 2009Routine · role: Involved in a Marine Casualty · activity 3543087
24 September 2009Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3602498
25 July 2012Routine · role: Involved in a Marine Casualty · activity 4391439
15 September 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4737096
30 January 2014Routine · role: Involved in a Marine Casualty · activity 4813392
29 June 2017Routine · role: Involved in a Marine Casualty · activity 6296025
6 October 2017Routine · role: Involved in a Marine Casualty · activity 6311082
21 June 2018Routine · role: Involved in a Marine Casualty · activity 6455404
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.