Records from 2016 to 2026. Most recent: inspection, 20 March 2026.
Documentation record
Registered dimensions (L × B × D)58.0 ft × 20.5 ft × 9.0 ft
Registered tonnagegross 71 / net 57
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderAQUA BAY MARINE INC · PANAMA CITY, FL, UNITED STATES · built 2003
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portORANGE BEACH, AL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it71 - Simplified, Gross Ton
57 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 13
20 March 2026
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8329432
17 February 2026
Vessel Attendance · Plan Review "T" Boat · In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8318730
20 May 2025
Administrative Inspection · Initial Certification · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8128799
3 March 2025
Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8087331
19 December 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7840709
6 July 2023
Administrative Inspection · Initial Certification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7734438
9 March 2023
Hull Examination · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7650343
16 June 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7479251
18 April 2022
Administrative Inspection · Simplified Stability Test
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7432988
16 June 2021
Administrative Inspection · Initial Certification
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7226724
29 April 2021
Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7185840
10 September 2017
Type not recorded
No type recorded · USCGC SITKINAK (WPB 1329) · USCG Northeast District (CGD-NE) · Activity 6264031
12 May 2016
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5879343
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 May 2025
Resolved
Valves for removing water or impurities from diesel fuel in water traps or strainers are permitted. These valves must be provided with caps or plugs to prevent fuel leakage. MI observed no caps or plugs were installed on fuel strainers to prevent leakage.
Cite: 46 CFR 182.455(b)(9)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2025
Resolution: Caps were installed, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 May 2025
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. MI observed the generator was unable to take on load.
Cite: 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2025
Resolution: Generator was able to take on load, all sat.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 20 May 2025
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate precaution against hazards that might endanger the vessel and the persons being transported. Vessel was unable to prove proficiency on man overboard, abandon ship, and fire-fighting drills drills due to not being able to get underway.
Cite: 46 CFR 185.100
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2025
Resolution: Conducted drills, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 20 May 2025
Resolved
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. MI observed the IBA to not be installed and ready for immediate use. Vessel's route is restricted to Lakes, Bays, and Sounds.
Cite: 46 CFR 185.700 (a)
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 21 May 2025
Resolution: IBA was installed, all sat.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 20 May 2025
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: (1) A space with a through-hull fitting below the deepest load waterline, such as a lazarette; (2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space; and (3) A space with a non-watertight closure, such as a space with a non-watertight hatch on the main deck. MI observed the audible alarm for the FWD bilge compartment to be nonoperational. Vessel crew is required to conduct rounds of the space every hour.
Cite: 46 CFR 182.530 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 June 2025
Resolution: Received objective evidence of repaired indicator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 May 2025
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. MI observed visual light was extinguised for the engine room bilge pump. Vessel crew is required to conduct rounds of the space every hour.
Cite: 46 CFR 182.530 (c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 June 2025
Resolution: Received objective evidence of operable indicating light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 May 2025
Resolved
Flexible nonmetallic hose must be complete with factory-assembled end fittings requiring no further adjustment of the fittings on the hose, or field attachable type fittings may be used. Hose end fittings must comply with SAE J-1475 (incorporated by reference; see 46 CFR 175.600). MI observed severely corroded end fittings on both hydraulic steering lines and reduction gear hoses on port main engine.
Cite: 46 CFR 182.720(e)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 June 2025
Resolution: Received objective evidence of replaced hydraulic steering and R/G lines and fittings.