← All vessels
QUICKSILVER
QUICKSILVER is a 2003 passenger vessel (inspected). The Coast Guard has recorded 27 inspections since 2016, most recently in February 2026, along with 48 deficiencies — 1 with no resolution recorded — and 10 casualty investigations between 2004 and 2016.
Records from 2004 to 2026. Most recent: inspection, 26 February 2026.
- Built
- 2003
- Last inspected
- 26 February 2026
- Documentation
- Valid · documentation file of 10 August 2026
- Deficiencies
- 48 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 10 investigations · 2004–2016
Identity
1144887
WDH2369
636517
Flag
UNITED STATES
Maury page id
psix-636517
Inspections, by type
…with no type recorded2
Years with a record
11 calendar years (2016–2026)
The 27 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Documentation record
Registered dimensions (L × B × D)55.0 ft × 23.0 ft × 7.5 ft
Registered tonnagegross 33 / net 26
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderISLAND BOATS, INC · JEANERETTE, LA, UNITED STATES · built 2003
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationTwin Hull
Hailing portMAALAEA, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 August 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it33 - Simplified, Gross Ton
26 - Simplified, Net Ton
26 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.
Inspection history · 27
26 February 2026
Annual Inspection · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8316815
6 November 2025
Vessel Attendance · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8217856
3 November 2025
Type not recorded
No type recorded · Station Honolulu · USCG Oceania District (CGD-O) · Activity 8262806
12 December 2024
Annual Inspection · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8046457
13 December 2023
Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7838362
29 August 2023
Deficiency Check · Drydock Exam · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7627160
21 March 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7652783
28 September 2022
In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7571027
16 September 2022
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7560632
3 March 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7404821
8 December 2021
Plan Review "T" Boat
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7369909
1 December 2021
In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7368758
21 October 2021
Deficiency Check · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7338060
23 March 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7161050
29 June 2020
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6990854
28 May 2020
Annual Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6963853
3 October 2019
Examination of Repairs · Deficiency Check · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6830043
20 February 2019
Administrative Inspection · COI Inspection · Internal Structural Exam · Deficiency Check · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6628976
2 May 2018
Deficiency Check · Internal Structural Exam · Drydock Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6404382
28 April 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6402533
28 February 2018
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6365080
4 August 2017
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6230790
7 June 2017
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6168926
26 April 2017
Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6132772
28 October 2016
Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6031079
5 June 2016
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5899718
19 April 2016
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5857814
Deficiency record · 48
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 February 2026
Resolved
A vessel of at least 7.9 meters (26 feet) in length must be provided with individual bilge lines and bilge suctions for each watertight compartment. Port fixed bilge aluminum piping found corroded and wasted with open holes in voids 2 and 3. Piping requires crop, repair and renewal to (03) areas identified during inspection. Vessel requires an operational test of the port fixed bilge system. Passenger count shall be reduced to 49 or less until new piping is installed due to presence of electric submersible bilge pumps installed in all compartments. 46 CFR 182.510(a)
09 - Working and Living Conditions › 092 - Working Conditions › Other (mooring)
Issued 26 February 2026
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices must be corrected and all required guards and protective devices must be in satisfactory condition. Starboard mooring cleat in way of void #2 broken off with jagged metal edge exposed. Repair and renew hazardous condition of broken cleat. 46 CFR 176.830(a)
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 6 November 2025
No resolution recorded
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs. Full penetration corrosion discovered at port side exhaust discharge on weld seam. A temporary weld repair is authorized. Permanent repairs are to be made at next scheduled drydocking.
46 CFR 176.600(d)
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 12 December 2024
Resolved
A vessel must be fitted with a FCC type accepted general marine radar system for surface navigation with a radar screen mounted at the primary operation station if: The vessel is self-propelled, the vessel has an oceans, coastwise, limited coastwise, or great lakes rout and the vessel carries more than 49 passengers. Vessel radar system requires new cable and radar dome. 46 CFR 184.404(a)
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 December 2023
Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. Ventilation blowers did not shut down when pre-engineered fixed system tested. Make blowers shut down when system operates.
46 CFR 181.420(a)(3)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 December 2023
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 1 inch numbers and letters at the entranceway to that deck. Vessel did not have the number of passengers allowed posted on stairwell. Provide proper upper deck marking.
46 CFR 185.602 (g)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 December 2023
Resolved
A propulsion engine control system must be designed so that a loss of power to the control system does not result in an increase in shaft speed. Electronic propulsion controller installed on vessel. QFA and DVTP not provided and test not completed. Provide QFA and DVTP to MSC in accordance with CVC-Policy Letter 17-07 and conduct testing IAW approved QFA and DVTP.
46 CFR 184.620
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 March 2023
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. The port lazarette high water light was inoperable. Replace the light.
46 CFR 182.530(c)
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 21 March 2023
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines at the tank connection. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. The vessel's starboard generator fuel shutoff valve did not fully close. Ensure proper closure.
46 CFR 182.455(b)(4)
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 21 March 2023
Resolved
Except on a vessel limited to daytime operations, the compass must be illuminated. Vessel's light was inoperable. Replace light.
46 CFR 184.402(c)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 March 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Dead end wire identified in the port lazarette compartment. Remove dead end wire.
46 CFR 183.200(c)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 March 2023
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. No portable lights were located at the access to the propulsion machinery spaces. Provide lights at the access point for each engine room.
46 CFR 183.430
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 3 March 2022
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines at the tank connection. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. The vessel's starboard generator fuel shutoff valve did not fully close. Ensure closure.
46 CFR 182.455(b)(4)
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 3 March 2022
Resolved
Each generator must be in a location that is accessible, adequately ventilated, and as dry as practicable. Discovered leak above generator overhead, dripping onto the generator. Provide drip shield for generator.
46 CFR 183.320(a)(1)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 March 2022
Resolved
Vessel does not currently meet the requirements of Work Instruction 31. Mandated crew posted on COI may not enter the water or act as lifeguard until policy and procedure provided. Provide written procedure.
Work Instruction 31
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 3 March 2022
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 x 30 mesh. No flame screen on port side. Install flame screen.
46 CFR 182.450(e)
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 3 March 2022
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Discovered 03 temporary repairs on bilge piping in the port void 3. Provide repair proposal for bilge piping.
46 CFR 176.700(a)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 March 2022
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. Bungee-cord brackets for fire extinguishers at the bottom of ladderwell are unapproved. Replace with manufacturer-approved brackets as referenced on each label.
46 CFR 181.500(a)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 March 2022
Resolved
A fire pump must be capable of both remote operation from the operating station and local operations at the pump. The sea fire pump did not have a valve for local operation. Provide local operation.
46 CFR 181.300(e)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 March 2022
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of a least 3 feet in length, but not more than 6 feet, securing the waterlight around the body of the ring life buoy. Waterlight lanyard too long. Provide 3-6 ft line.
46 CFR 180.70(d)(2)
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 3 March 2022
Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Contents of medical kit were expired. Replace expired contents.
46 CFR 184.710
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 March 2022
Resolved
Electrical equipment on a vessel must be installed to protect the vessel from electrical hazards, including fire. Discovered surge protectors and extension cord rigged. Operator removed surge protectors and extension cord in presence of Marine Inspector.
46 CFR 183.200(c)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 November 2021
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. The vessel's onboard service generator has been replaced without receiving approval from USCG MSC or the cognizant OCMI. Vessel is prohibited from utilizing the onboard service generator while carrying passengers, unless required for an emergency, until approval for the installation is received by USCG MSC and the installation is verified and approved by an attending USCG Marine Inspector.46CFR176.700(a)
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 March 2021
Resolved
Missing 01 portable fire extinguisher. COI states four 40-B:C extinguishers are to be on board. Only three currently on board. Provide 01 extinguisher to meet COI.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 March 2021
Resolved
Two portable fire extinguishers condemned due to corrosion. Provide two serviced 40-B:C portable extinguishers to replace the condemned two.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 March 2021
Resolved
Four surge protectors located in pilot house each with numerous devices plugged in. Two surge protectors daisy chained. Remove all surge protectors. Devices should be plugged directly to junction box to prevent potential overloading.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 23 March 2021
Resolved
Guard for fan/blower in generator room missing. Provide guard for fan/blower.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 March 2021
Resolved
Flammable materials found at pilot station. Remove flammable materiel from vessel or provide flame Locker for storage.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 March 2021
Resolved
Numerous dead end wiring found under helm. Remove all dead end wiring.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 23 March 2021
Resolved
Compass light not operational. Provide operational compass light.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 23 March 2021
Resolved
Port sewage overboard valve not locked. Provide lock for sewage overboard valve.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 March 2021
Resolved
Starboard side pre-engineered fixed fire fighting Sea Fire system when in override would not shut down engine. Provide means for shutting engine down once in override with out having to enter the engine room.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 23 March 2021
Resolved
Missing current tide table and chart. Provide current tide table and updated 19348 chart.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 March 2021
Resolved
Two vertically stacked electric ovens installed. No plans submitted prior to installation for flame spread or electrical use. Provide oven installation plans, electrical plans, and technical specification for ovens.
Rectify prior to use of oven.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 March 2021
Resolved
Hydraulic leak located on port steering unit. Trace and secure leak.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 March 2021
Resolved
New electrical outlets installed. Provide updated
drawing with newly installed electrical items.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 May 2020
Resolved
Pre-engineered fixed gas system must be capable of manual activation in accordance with 46 CFR 181.420. Port system manual activation pull cable was seized.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 May 2020
Resolved
Testing/readiness of piping systems in accordance with 46 CFR 176.804. Cross bilge suction line in port mid space was corroded through.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 May 2020
Resolved
Inspect watertight bulkheads in accordance 46 CFR 176.802. Port fwd eng compartment bulkhead had two open penetrations
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 May 2020
Resolved
Test navigation lights in accordance with 46 CFR 176.816. Navigation running lights were not properly fastened.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 20 February 2019
Resolved
Vessel is equipped with radar in accordance with 46 CFR 184.404. Radar was not operating correctly in accordance with 46 CFR 176.816. Vessel is limited to fair weather operations only and limited 49 passengers after sunset. Vessel captain is required to check weather prior to departure. Deficiency to be corrected by 02/28/2019.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 20 February 2019
Resolved
Compass is required by 46 CFR 184.402. Compass light was inoperative. Repair in accordance with 46 CFR 176.816. Vessel limited to day-time operations only.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 28 April 2018
Resolved
13199-Stbd shaft damaged by incident. Complete repairs and prove satisfactory operation of propulsion.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 4 August 2017
Resolved
**Deficiency was issued on 04NOV2016, and extended to 28FEB2017** Provide fuses to protect circuits which meet the requirements of 46 CFR 183.380(a) and 46 CFR 183.380(l). Overcurrent protection must be designed to protect the conductors in the circuits which they protect.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 4 August 2017
Resolved
**Deficiency was issued on 04NOV2016, and extended to 28FEB2017** Provide plan to replace UL recognized circuit breakers installed on board in the vessel's AC system, with overcurrent protection which meets 46 CFR 183.380(a) and either 46 CFR 183.380(l) or (m).
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 4 August 2017
Resolved
**Deficiency was issued on 04NOV2016, and extended to 28FEB2017** Provide overcurrent protection for the generator that meets 46 CFR 183.320(f). Generator overcurrent protection must not be rated higher than 115% of the generator rating of 33.3 amps. So generator must be protected with a circuit breaker with a max rating of no more than 40 amps.
Stability › Watertight Integrity › General
Issued 28 October 2016
Resolved
Properly seat watertight gasket located in the portside hull, compartment #2.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 28 October 2016
Resolved
Replace in kind the wasted seat supports for the seating located on the upper deck forward of the pilot house. Passengers are restricted from this seating area until rectified.
Casualty record · 10
1 April 2004Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2047870
17 April 2006Routine · role: Involved in a Marine Casualty · activity 2770807
20 June 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 2717613
24 August 2006Routine · role: Involved in a Marine Casualty · 1 dead · activity 2917262
23 February 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3684301
12 April 2013Routine · role: Acknowledged Pollution Source · activity 4567824
15 April 2013Routine · role: Acknowledged Pollution Source · activity 4569455
20 January 2015Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 5056758
7 October 2015Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5899593
5 June 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5899718
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.