QUICKSILVER

QUICKSILVER is a 2003 passenger vessel (inspected). The Coast Guard has recorded 27 inspections since 2016, most recently in February 2026, along with 48 deficiencies — 1 with no resolution recorded — and 10 casualty investigations between 2004 and 2016.

Records from 2004 to 2026. Most recent: inspection, 26 February 2026.

Built
2003
Last inspected
26 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDH2369
636517
Flag
UNITED STATES
Maury page id
psix-636517

Inspections, by type

…with no type recorded2
Years with a record 11 calendar years (2016–2026)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)55.0 ft × 23.0 ft × 7.5 ft
Registered tonnagegross 33 / net 26
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderISLAND BOATS, INC · JEANERETTE, LA, UNITED STATES · built 2003
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationTwin Hull
Hailing portMAALAEA, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 August 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it33 - Simplified, Gross Ton
26 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 27

26 February 2026 Annual Inspection · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8316815
6 November 2025 Vessel Attendance · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8217856
3 November 2025 Type not recorded
No type recorded · Station Honolulu · USCG Oceania District (CGD-O) · Activity 8262806
12 December 2024 Annual Inspection · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8046457
13 December 2023 Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7838362
29 August 2023 Deficiency Check · Drydock Exam · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7627160
21 March 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7652783
28 September 2022 In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7571027
16 September 2022 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7560632
3 March 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7404821
8 December 2021 Plan Review "T" Boat
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7369909
1 December 2021 In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7368758
21 October 2021 Deficiency Check · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7338060
23 March 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7161050
29 June 2020 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6990854
28 May 2020 Annual Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6963853
3 October 2019 Examination of Repairs · Deficiency Check · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6830043
20 February 2019 Administrative Inspection · COI Inspection · Internal Structural Exam · Deficiency Check · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6628976
2 May 2018 Deficiency Check · Internal Structural Exam · Drydock Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6404382
28 April 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6402533
28 February 2018 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6365080
4 August 2017 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6230790
7 June 2017 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6168926
26 April 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6132772
28 October 2016 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6031079
5 June 2016 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5899718
19 April 2016 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5857814

Deficiency record · 48

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 26 February 2026 Resolved
A vessel of at least 7.9 meters (26 feet) in length must be provided with individual bilge lines and bilge suctions for each watertight compartment. Port fixed bilge aluminum piping found corroded and wasted with open holes in voids 2 and 3. Piping requires crop, repair and renewal to (03) areas identified during inspection. Vessel requires an operational test of the port fixed bilge system. Passenger count shall be reduced to 49 or less until new piping is installed due to presence of electric submersible bilge pumps installed in all compartments. 46 CFR 182.510(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 March 2026
Resolved 27 February 2026
Resolution: Fixed bilge piping croped and renewed. System operationally tested. No further requirements.
09 - Working and Living Conditions › 092 - Working Conditions › Other (mooring)
Issued 26 February 2026 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices must be corrected and all required guards and protective devices must be in satisfactory condition. Starboard mooring cleat in way of void #2 broken off with jagged metal edge exposed. Repair and renew hazardous condition of broken cleat. 46 CFR 176.830(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 February 2026
Resolution: Hazardous condition removed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 6 November 2025 No resolution recorded
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs. Full penetration corrosion discovered at port side exhaust discharge on weld seam. A temporary weld repair is authorized. Permanent repairs are to be made at next scheduled drydocking. 46 CFR 176.600(d)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2027
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 12 December 2024 Resolved
A vessel must be fitted with a FCC type accepted general marine radar system for surface navigation with a radar screen mounted at the primary operation station if: The vessel is self-propelled, the vessel has an oceans, coastwise, limited coastwise, or great lakes rout and the vessel carries more than 49 passengers. Vessel radar system requires new cable and radar dome. 46 CFR 184.404(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2024
Resolved 18 December 2024
Resolution: New dome and wired installed. Radar transmitting to main screen at operating station. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 13 December 2023 Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. Ventilation blowers did not shut down when pre-engineered fixed system tested. Make blowers shut down when system operates. 46 CFR 181.420(a)(3)
Action required: 10 - Deficiency Rectified
Resolved 13 December 2023
Resolution: Blower wired into pre-engineered fixed fire fighting system.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 December 2023 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 1 inch numbers and letters at the entranceway to that deck. Vessel did not have the number of passengers allowed posted on stairwell. Provide proper upper deck marking. 46 CFR 185.602 (g)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2024
Resolved 22 January 2024
Resolution: Marking provided for upper deck.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 December 2023 Resolved
A propulsion engine control system must be designed so that a loss of power to the control system does not result in an increase in shaft speed. Electronic propulsion controller installed on vessel. QFA and DVTP not provided and test not completed. Provide QFA and DVTP to MSC in accordance with CVC-Policy Letter 17-07 and conduct testing IAW approved QFA and DVTP. 46 CFR 184.620
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2024
Resolved 12 March 2024
Resolution: DVTP testing completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 March 2023 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. The port lazarette high water light was inoperable. Replace the light. 46 CFR 182.530(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 April 2023
Resolved 2 April 2023
Resolution: Bilge indicator light replaced and operable.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 21 March 2023 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines at the tank connection. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. The vessel's starboard generator fuel shutoff valve did not fully close. Ensure proper closure. 46 CFR 182.455(b)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2023
Resolved 21 March 2023
Resolution: Fuel shut off valve repaired and can fully close.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 21 March 2023 Resolved
Except on a vessel limited to daytime operations, the compass must be illuminated. Vessel's light was inoperable. Replace light. 46 CFR 184.402(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2023
Resolved 2 April 2023
Resolution: Compass light replaced and operable.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 21 March 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Dead end wire identified in the port lazarette compartment. Remove dead end wire. 46 CFR 183.200(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2023
Resolved 2 April 2023
Resolution: Dead end wire removed from port lazarette compartment.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 March 2023 Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. No portable lights were located at the access to the propulsion machinery spaces. Provide lights at the access point for each engine room. 46 CFR 183.430
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2023
Resolved 2 April 2023
Resolution: Lights provided at the access point of each engine room.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 3 March 2022 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines at the tank connection. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. The vessel's starboard generator fuel shutoff valve did not fully close. Ensure closure. 46 CFR 182.455(b)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 March 2022
Resolution: Fuel shut off repaired fully closes.
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 3 March 2022 Resolved
Each generator must be in a location that is accessible, adequately ventilated, and as dry as practicable. Discovered leak above generator overhead, dripping onto the generator. Provide drip shield for generator. 46 CFR 183.320(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 March 2022
Resolution: Deck holes capped to prevent leak.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 March 2022 Resolved
Vessel does not currently meet the requirements of Work Instruction 31. Mandated crew posted on COI may not enter the water or act as lifeguard until policy and procedure provided. Provide written procedure. Work Instruction 31
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 March 2022
Resolution: At owners request removed WI 31 from COI conditions of operations.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 3 March 2022 Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 x 30 mesh. No flame screen on port side. Install flame screen. 46 CFR 182.450(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 March 2022
Resolution: Flame screen provided.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 3 March 2022 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. Discovered 03 temporary repairs on bilge piping in the port void 3. Provide repair proposal for bilge piping. 46 CFR 176.700(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 March 2022
Resolution: Bilge piping repaired.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 March 2022 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. Bungee-cord brackets for fire extinguishers at the bottom of ladderwell are unapproved. Replace with manufacturer-approved brackets as referenced on each label. 46 CFR 181.500(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 March 2022
Resolution: Brackets provided.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 March 2022 Resolved
A fire pump must be capable of both remote operation from the operating station and local operations at the pump. The sea fire pump did not have a valve for local operation. Provide local operation. 46 CFR 181.300(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 March 2022
Resolution: Local operation provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 March 2022 Resolved
Each ring life buoy with a floating waterlight must have a lanyard of a least 3 feet in length, but not more than 6 feet, securing the waterlight around the body of the ring life buoy. Waterlight lanyard too long. Provide 3-6 ft line. 46 CFR 180.70(d)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 March 2022
Resolution: 3-6 ft line provided.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 3 March 2022 Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Contents of medical kit were expired. Replace expired contents. 46 CFR 184.710
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 March 2022
Resolution: Expired contents replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 March 2022 Resolved
Electrical equipment on a vessel must be installed to protect the vessel from electrical hazards, including fire. Discovered surge protectors and extension cord rigged. Operator removed surge protectors and extension cord in presence of Marine Inspector. 46 CFR 183.200(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 March 2022
Resolution: Surge protectors removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 November 2021 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. The vessel's onboard service generator has been replaced without receiving approval from USCG MSC or the cognizant OCMI. Vessel is prohibited from utilizing the onboard service generator while carrying passengers, unless required for an emergency, until approval for the installation is received by USCG MSC and the installation is verified and approved by an attending USCG Marine Inspector.46CFR176.700(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 December 2021
Resolved 8 December 2021
Resolution: [name withheld] attended for electrical inspection IAW approved plans. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 March 2021 Resolved
Missing 01 portable fire extinguisher. COI states four 40-B:C extinguishers are to be on board. Only three currently on board. Provide 01 extinguisher to meet COI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2021
Resolution: New extinguisher provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 March 2021 Resolved
Two portable fire extinguishers condemned due to corrosion. Provide two serviced 40-B:C portable extinguishers to replace the condemned two.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2021
Resolution: New extinguishers provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 March 2021 Resolved
Four surge protectors located in pilot house each with numerous devices plugged in. Two surge protectors daisy chained. Remove all surge protectors. Devices should be plugged directly to junction box to prevent potential overloading.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2021
Resolution: Surge protectors provided.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 23 March 2021 Resolved
Guard for fan/blower in generator room missing. Provide guard for fan/blower.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2021
Resolved 25 March 2021
Resolution: Guard provided for fan.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 March 2021 Resolved
Flammable materials found at pilot station. Remove flammable materiel from vessel or provide flame Locker for storage.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2021
Resolved 24 March 2021
Resolution: Flammables removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 March 2021 Resolved
Numerous dead end wiring found under helm. Remove all dead end wiring.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2021
Resolved 2 April 2021
Resolution: Dead end wires removed.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 23 March 2021 Resolved
Compass light not operational. Provide operational compass light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2021
Resolved 31 March 2021
Resolution: Compass light operational.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 23 March 2021 Resolved
Port sewage overboard valve not locked. Provide lock for sewage overboard valve.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2021
Resolved 31 March 2021
Resolution: Overboard locked
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 March 2021 Resolved
Starboard side pre-engineered fixed fire fighting Sea Fire system when in override would not shut down engine. Provide means for shutting engine down once in override with out having to enter the engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2021
Resolved 24 March 2021
Resolution: Override operational.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 23 March 2021 Resolved
Missing current tide table and chart. Provide current tide table and updated 19348 chart.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2021
Resolved 25 March 2021
Resolution: Chart and light list provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 March 2021 Resolved
Two vertically stacked electric ovens installed. No plans submitted prior to installation for flame spread or electrical use. Provide oven installation plans, electrical plans, and technical specification for ovens. Rectify prior to use of oven.
Action required: 705 - Other - as specified
Resolved 31 March 2021
Resolution: Ovens removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 March 2021 Resolved
Hydraulic leak located on port steering unit. Trace and secure leak.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2021
Resolved 20 April 2021
Resolution: New ram installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 March 2021 Resolved
New electrical outlets installed. Provide updated drawing with newly installed electrical items.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 April 2021
Resolved 22 April 2021
Resolution: New outlets installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 May 2020 Resolved
Pre-engineered fixed gas system must be capable of manual activation in accordance with 46 CFR 181.420. Port system manual activation pull cable was seized.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 June 2020
Resolution: Port Fireboy pull cable was repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 May 2020 Resolved
Testing/readiness of piping systems in accordance with 46 CFR 176.804. Cross bilge suction line in port mid space was corroded through.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 June 2020
Resolution: Corroded bilge piping was renewed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 May 2020 Resolved
Inspect watertight bulkheads in accordance 46 CFR 176.802. Port fwd eng compartment bulkhead had two open penetrations
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2020
Resolved 29 June 2020
Resolution: Port fwd eng compartment bulkhead penetrations made water tight with plate, epoxy and mechanical fasteners. Added special note to repair via insert at next drydock.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 May 2020 Resolved
Test navigation lights in accordance with 46 CFR 176.816. Navigation running lights were not properly fastened.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2020
Resolved 29 June 2020
Resolution: Navigation lights secured.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 20 February 2019 Resolved
Vessel is equipped with radar in accordance with 46 CFR 184.404. Radar was not operating correctly in accordance with 46 CFR 176.816. Vessel is limited to fair weather operations only and limited 49 passengers after sunset. Vessel captain is required to check weather prior to departure. Deficiency to be corrected by 02/28/2019.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 February 2019
Resolution: Radar repaired.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 20 February 2019 Resolved
Compass is required by 46 CFR 184.402. Compass light was inoperative. Repair in accordance with 46 CFR 176.816. Vessel limited to day-time operations only.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 February 2019
Resolution: Compass light repaired.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 28 April 2018 Resolved
13199-Stbd shaft damaged by incident. Complete repairs and prove satisfactory operation of propulsion.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 May 2018
Resolved 15 May 2018
Resolution: Repairs completed and satisfactory sea trials completed.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 4 August 2017 Resolved
**Deficiency was issued on 04NOV2016, and extended to 28FEB2017** Provide fuses to protect circuits which meet the requirements of 46 CFR 183.380(a) and 46 CFR 183.380(l). Overcurrent protection must be designed to protect the conductors in the circuits which they protect.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 August 2017
Resolved 28 February 2018
Resolution: Correct fuse installed.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 4 August 2017 Resolved
**Deficiency was issued on 04NOV2016, and extended to 28FEB2017** Provide plan to replace UL recognized circuit breakers installed on board in the vessel's AC system, with overcurrent protection which meets 46 CFR 183.380(a) and either 46 CFR 183.380(l) or (m).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 August 2017
Resolved 28 February 2018
Resolution: Correct circuit breakers installed.
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 4 August 2017 Resolved
**Deficiency was issued on 04NOV2016, and extended to 28FEB2017** Provide overcurrent protection for the generator that meets 46 CFR 183.320(f). Generator overcurrent protection must not be rated higher than 115% of the generator rating of 33.3 amps. So generator must be protected with a circuit breaker with a max rating of no more than 40 amps.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 August 2017
Resolved 28 February 2018
Resolution: Correct circuit breaker installed.
Stability › Watertight Integrity › General
Issued 28 October 2016 Resolved
Properly seat watertight gasket located in the portside hull, compartment #2.
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 28 February 2018
Resolution: Watertight gasket renewed.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 28 October 2016 Resolved
Replace in kind the wasted seat supports for the seating located on the upper deck forward of the pilot house. Passengers are restricted from this seating area until rectified.
Action required: 705 - Other - as specified
Due 8 December 2016
Resolved 28 February 2018
Resolution: Seating repaired.

Casualty record · 10

1 April 2004Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2047870
17 April 2006Routine · role: Involved in a Marine Casualty · activity 2770807
20 June 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 2717613
24 August 2006Routine · role: Involved in a Marine Casualty · 1 dead · activity 2917262
23 February 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3684301
12 April 2013Routine · role: Acknowledged Pollution Source · activity 4567824
15 April 2013Routine · role: Acknowledged Pollution Source · activity 4569455
20 January 2015Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 5056758
7 October 2015Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5899593
5 June 2016Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5899718
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.