Records from 2003 to 2019. Most recent: inspection, 5 March 2019.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 14
5 March 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6636682
6 September 2018
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6534379
20 June 2014
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4894360
19 June 2014
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4894444
20 July 2012
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4385068
1 July 2012
Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4365417
15 December 2010
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3911476
20 January 2009
Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3397917
31 January 2008
Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3135661
29 January 2007
Hull Examination · Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2863697
6 April 2006
Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2618489
8 April 2004
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2040362
18 November 2003
Initial Certification
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1946504
29 July 2003
Construction Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1853847
Construction/Loadline › Penetrations › Gasket
Issued 1 July 2012
Resolved
Properly repair rear drive axle and prove proper operation to the satisfaction by the attending Marine Inspector.
Action required: 705 - Other - as specified
Resolved 2 July 2012
Resolution: Vessel properly installed parts and successfully tested.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Nozzle
Issued 15 December 2010
Resolved
Install discharge nozzle inside main engine space for fixed CO2 fire extinguishing system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 December 2010
Resolved 16 December 2010
Resolution: Discharge nozzle installed inside main engine space. Verified proper operation.
Communications › Alarms/Indicators › General Alarm
Issued 20 January 2009
Resolved
Prove operation of vapor detection device fwd eng space. 46 CFR 182.410 (c).
Action required: 705 - Other - as specified
Due 21 January 2009
Resolved 20 January 2009
Resolution: Replaced and tested sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 30 January 2008
Resolved
Prove proper operation of water light.
Action required: 705 - Other - as specified
Due 1 February 2008
Resolved 31 January 2008
Electrical › Electric Supply System (service) › Cable
Issued 29 January 2007
Resolved
Prove proper connection of battery cables to terminals.
Condition: Unknown
Due 29 January 2007
Resolved 29 January 2007
Resolution: Tightened battery connections.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Automatic Heat Detectors
Issued 29 January 2007
Resolved
Prove electrically supervised fire/heat detection circuit.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 May 2007
Resolved 10 May 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 29 January 2007
Resolved
Prove engine room bilge exhaust blower shutdown upon activation of fixed CO2 system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 February 2007
Resolved 1 February 2007
Resolution: Installed blower to shutdown upon activation of CO2 system.
Engineering › Steering Gear System › Linkage
Issued 29 January 2007
Resolved
Prove proper attachment of stbd tiller arm to rudder shaft.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 February 2007
Resolved 29 January 2007
Resolution: Tightened tiller arm.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 18 November 2003
Resolved
Properly mark all life rings and life buoys with vessel name. LEGACY COMPONENT DESC: Marking
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 November 2003
Resolved 14 April 2006