Records from 2005 to 2026. Most recent: inspection, 12 February 2026.
Inspection history · 74
12 February 2026
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8310084
5 February 2026
In-Service Inspection · Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8306843
5 February 2026
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8307050
2 December 2025
Annual Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8276205
13 September 2025
In-Service Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8233560
13 September 2025
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8261455
29 July 2025
Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8197551
20 June 2025
Plan Review "T" Boat
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 8163073
15 January 2025
Hull Examination · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8063775
5 December 2024
Annual Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8043491
8 November 2024
In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8032270
11 September 2024
Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8000857
25 May 2024
Deficiency Check · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7919351
7 May 2024
In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7907849
24 March 2024
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7884821
24 March 2024
Deficiency Check · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7885926
21 March 2024
Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7909539
5 March 2024
Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7909437
16 October 2023
Examination of Repairs · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7809015
13 October 2023
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7809154
7 September 2023
Deficiency Check · COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7784875
17 April 2023
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7686023
23 February 2023
Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7640642
10 February 2023
Examination of Repairs · Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7634962
5 January 2023
Drydock Extension · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7617047
27 December 2022
Examination of Repairs · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7613852
20 October 2022
Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7581074
19 October 2022
Construction Oversight · Plan Review "T" Boat
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7580202
18 October 2022
Deficiency Check · Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7579510
6 September 2022
In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7552786
6 August 2022
Damage Survey · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7526025
6 August 2022
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7529135
23 July 2022
Deficiency Check · Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7515799
10 July 2022
Damage Survey · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7504443
7 December 2021
Examination of Repairs · Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7363974
7 December 2021
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7365434
13 October 2021
Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7331624
23 July 2021
Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7265191
23 July 2021
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7269537
7 July 2021
In-Service Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7248592
18 May 2021
Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7199846
2 May 2021
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7199891
7 December 2020
Administrative Inspection · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7090815
14 October 2020
Plan Review "T" Boat
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7077146
14 October 2020
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7077798
14 October 2020
Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7079808
8 October 2020
Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7073714
4 July 2020
Administrative Inspection · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6996122
4 July 2020
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 7001568
10 December 2019
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6868917
10 September 2019
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6807311
15 July 2019
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6750482
20 June 2019
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6913054
6 June 2019
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6743598
7 May 2019
Damage Survey · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6679067
7 May 2019
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6684653
10 January 2019
Hull Examination · Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6608321
22 December 2018
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6605229
6 September 2018
Administrative Inspection · COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6534105
13 August 2018
Administrative Inspection · Deficiency Check
Physical examination · Navigation Center · Activity 6510684
17 July 2018
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6483792
12 June 2018
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6468262
7 November 2017
Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6302171
3 October 2017
Plan Review "T" Boat
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6280179
19 September 2017
Annual Inspection · Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6270370
9 August 2017
Damage Survey · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6243415
7 July 2017
Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6243177
13 June 2017
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6176485
14 March 2017
Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6104713
6 March 2017
In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6099747
5 December 2016
Damage Survey · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6052988
4 December 2016
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6055507
12 September 2016
Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5998558
20 January 2016
Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 5804165
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 2 December 2025
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. The alrarm for the #2 starboard compartment did not work.
Action required: 10 - Deficiency Rectified
Resolved 3 December 2025
Resolution: A new float switch was installed on the spot.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 2 December 2025
Resolved
On a vessel of 65 feet in length, the minimum capacity of the fire pump must be 50 gallons per minute at a pressure of not less than 60 psi at the pump outlet. The pump outlet must be fitted with a pressure gauge. The pressure gauge was not working.
Action required: 10 - Deficiency Rectified
Resolved 3 December 2025
Resolution: A new gauge was installed.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 2 December 2025
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. The flashlight batteries were dead.
Action required: 10 - Deficiency Rectified
Resolved 3 December 2025
Resolution: Replaced the battaries in the flashlights.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 December 2025
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. The lower red mast light is not operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2025
Resolved 18 December 2025
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 2 December 2025
Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material, except in an accommodation space, radio room, galley, or similar space where it is not subject to damage. The light cover over the starboard main engine is damaged due to heat.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2025
Resolved 18 December 2025
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 2 December 2025
No resolution recorded
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. The starboard stern tube packing has a minimal leak; repairs to be made at next haul out or NLT the next dry dock date.
Action required: 705 - Other - as specified
Due 17 December 2025 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 September 2025
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury; vessel experience a loss of propulsion on the port engine. Vessel is to make repairs and successful power trial to the satisfaction of the Coast Guard. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 19 September 2025
Resolved 15 September 2025
Resolution: Replaced the raw water intake pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 December 2024
Resolved
The vessel must be provided with a satisfactory arrangement for draining any watertight compartment to include bilge pumps in accordance with Table 182.521 (e). The port side bilge piping has a hole where the piping connects to the bilge manifold suction valve, and the starboard bilge piping has a fractured weld in the forepeak line in way of the manifold.
IAW 46 CFR 182.500
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 December 2024
Resolved
Electrical equipment must be installed and maintained to protest personnel and the vessel from electrical hazards. The port navigation light and the upper not under command light wiring is compromised due to chaffing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 December 2024
Resolved 6 December 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 11 September 2024
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury; vessel experienced loss of propulsion to have the capability to reverse on the starboard main diesel engine (STBD MDE). Vessel is to make repairs and successful power trial to the satisfaction of the Coast Guard. 46 CFR 182.100
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 September 2024
Resolved 14 September 2024
Resolution: 14SEP24 - Attended vessel and witnessed power trials on STBD Engine; all SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 October 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations; vessel's port engine was secured while operating due to coolant leak caused by failed o-ring
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 16 October 2023
Resolved 16 October 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 September 2023
Resolved
The vessel must be provided with a satisfactory bilge piping arrangement for draining any watertight compartment. The bilge pipe piercing the collision bulkhead must be fitted with a screw down valve operable from the weather deck. The cables attached to the fore peak valves are broken and not operational.
Condition: Unknown
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2023
Resolved 27 September 2023
Resolution: New valves and remote actuators installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 September 2023
Resolved
Electrical equipment used in the distribution of power in machinery spaces must be watertight. The #2 steering pump controller has a loose cover and no gasket.
Condition: Unknown
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2023
Resolved 15 September 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 23 February 2023
Resolved
Annual inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date; vessel was not operating and did not have annual inspection.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 23 February 2023
Resolved 23 February 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 October 2022
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations; vessel is experiencing excessive vibration in running gear after striking submerged object.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 November 2022
Resolution: Props repaired and reinstalled
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 18 October 2022
Resolved
A vessel must be provided with a main steering gear that is Capable of moving the rudder from 35 degrees on one side to 30 degrees on the other side in not more than 28 seconds with the vessel moving ahead at maximum service speed; vessel lost control of steering after electric steering pump shutdown.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 October 2022
Resolution: New STBD gen feed braker installed
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 7 July 2021
Resolved
Deck rails must be designed and constructed to withstand a point load of 200 pounds applied at any point in any direction; there are several fractures in the stbd aft handrails in way of the luggage cart storage area.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 July 2021
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 23 February 2021
Resolved
The main deck and 02 deck, has missing and broken non skid throughout. Replace missing and or damaged areas.
Originally issued as worklist item on 7 Dec. 2020. Work was not completed while in drydock due to unavailability of necessary material. Converted to CG-835 on 23 Feb. 2021.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 May 2021
Resolution: All non-skid was repalaced
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 7 December 2020
Resolved
Anchor chain wasted and anchor windless motor wasted
Action required: 705 - Other - as specified
Resolved 16 February 2021
Resolution: Vessel rep removed and completed modification. Rep used approved mod from vsl RANGER that MSC approved. Uploaded information in MISLE. No discussion was had with MI's and install tested SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 October 2020
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel, its operation, and for the purpose intended; the port main engine is not operational.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 October 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 July 2020
Resolved
All marine engineering details, such as main and auxiliary machinery shall be designed, constructed, and installed in accordance with the provisions of Subchapter F of Part 46. Vsl experienced loss of propulsion due to failed solenoid on stc valve on port engine. Repair and conduct sea trials to prove proper operation to satisfaction of attending marine inspector prior to carrying passenengers.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 July 2020
Resolution: Attended vessel, conducted sea trials, all sat.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 10 September 2019
Resolved
Shutoff valves for fuel supply shall be operable from outside the space. The port MDE remote fuel valve is seized.
Action required: 10 - Deficiency Rectified
Resolved 10 September 2019
Resolution: Valve was broke free and lubricted prior to departing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 September 2019
Resolved
A bilge pipe piercing the collision bulkhead must be fitted with a valve on the forward side of the bulkhead and be operable from the weather deck. Both port and starboard valves are seized.
Action required: 10 - Deficiency Rectified
Resolved 10 September 2019
Resolution: Valve was broke free and lubricted prior to departing.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 10 September 2019
Resolved
A vsl with a power driven steering gear shall be provided with a rudder angle indicator. The port RAI is only showing 20' to stbd.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2019
Resolution: RAI adjusted and matching within 1'
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 September 2019
Resolved
Engine exhaust must be supported. The port M/E exhaust support bracket is fractured.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2019
Resolution: Corrected
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 September 2019
Resolved
Battery charger is not properly sucured and is wearing a hole in the FRP exhaust. Secure or relocate battery charger.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 September 2019
Resolution: Corrected
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 7 May 2019
Resolved
There are two fractures in the transom of the port hull and one fracture in the transom of the stbd hull; make repairs as discussed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2019
Resolution: Repairs carried out in accordance with approved proposal.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 24 January 2019
Resolved
Anchor windless is inoperable and causing a potentially hazardous situation. Repair, replace, or remove anchor windless. If replacing submit replacement part info to OCMI for approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 May 2019
Resolution: Windless motor was removed and the electrical wires properly secured.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 September 2018
Resolved
Replace the reflective tape on the ring buoy's as needed due to deterioration.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 October 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 September 2018
Resolved
Provide a protective cover for the AC meter on the stbd generator control panel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 October 2018
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 25 September 2018
Resolved
Repair or replace the emergency lights as needed; two were noted as not operational, one in the bridge and one on the port weather deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 October 2018
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 September 2018
Resolved
Replace/repair and calibrate the gauges for the port and stbd fire pumps.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 October 2018
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 13 August 2018
Resolved
The vessel is currently broadcasting (1) Zero Length or Beam (2) Zero Draft
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 September 2018
Resolved 30 August 2018
Resolution: Vessel operator notified me that they had corrected all AIS static discrepancies. Verified in VIVS.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 18 December 2017
Resolved
In accordance with approval letter 16710/6280179 dated OCT 5, 2017, paragraph 1 provide operating station with a rudder angle indicator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 December 2017
Engineering › Steering Gear System › Rudder
Issued 18 December 2017
Resolved
In accordance with approval letter 16710/6280179 dated Oct 5, 2017, paragraph 2 provide limit switch for port side steering system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 December 2017
Electrical › Electrical Distribution System (service) › Junction Box
Issued 18 December 2017
Resolved
Replace electrical box for sewage water pump in port side steering space. Ensure box is of watertight design.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 December 2017
Fire Fighting › Fire Pumps › Arrangement
Issued 18 December 2017
Resolved
Replace fire pump gauge on port side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 December 2017
Engineering › Fuel Oil Service System › Valve
Issued 20 September 2017
Resolved
Port M/E Fuel Supply Shut-Off valve inoperable. Repair and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 September 2017
Resolved 22 September 2017
Resolution: Remote valve pull handle was replaced and tested twice.
Communications › Alarms/Indicators › Bilge Alarm
Issued 20 September 2017
Resolved
Starboard #2 Compartment high level bilge alarm inoperable. Repair and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 September 2017
Resolved 22 September 2017
Resolution: Bilge alarm was tested satisfactory.
Engineering › Bilge Water Management System › Valve
Issued 20 September 2017
Resolved
Port and Starboard bilge pipe valve closures forward of the collision bulkhead inopearble. Repair and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 September 2017
Resolved 22 September 2017
Resolution: Pull cables were replaced and tested satisfactory.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 20 September 2017
Resolved
Starboard Engine Room power ventilation control stuck in "ON" position. Repair and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 September 2017
Resolved 22 September 2017
Resolution: Ventilation controller was tested along with the auto shutdown of installed F/F. Test satisfactory.
Engineering › Fuel Oil Service System › Filter
Issued 20 September 2017
Resolved
Port M/E fuel filter bowls (2) have drain cocks without plugs. Replace valves with solid bottom valves with plugs.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 October 2017
Resolved 22 September 2017
Resolution: Plugs were installed in the drain plugs.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 20 September 2017
Resolved
(2) portable fire extinguishers located in the passenger accommodation space on the main deck require monthly maintenance.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2017
Resolved 22 September 2017
Resolution: Both extinguishers received monthly checks and have been marked accordingly.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 20 September 2017
Resolved
Mark the number of life jackets stowed inside storage compartments in passenger accomodation area on the main deck.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 October 2017
Resolved 22 September 2017
Resolution: Storage compartments have been marked.
Electrical › Lighting (service) › Lighting Fixture
Issued 20 September 2017
Resolved
Secure ligh fixture on overhead outside of pilot house.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2017
Resolved 22 September 2017
Resolution: Light fixture was properly secured.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 September 2017
Resolved
Mast light extinguished. Replace and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 September 2017
Resolved 22 September 2017
Resolution: Mast light was tested and is operating properly.
Engineering › Fuel Oil Service System › Filter
Issued 14 March 2017
Resolved
Prove proper operation of the port MDE and maintenance of fuel system.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 14 March 2017
Resolution: Conducted satisfactory sea trial and visual inspection of port fuel filters.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 22 September 2016
Resolved
Obtain ready alcohol test strips, current onboard are expired.
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 November 2016
Resolved 23 September 2016
Resolution: Vessel has ordered new alcohol test strips.
Construction/Loadline › Hull › Hull Plating
Issued 20 January 2016
Resolved
Crop and renew area of hull plating in STBD engine compt. Area of concern is behind previous muffler. Approx 2' X 5'
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2016
Resolution: Repairs have been made, all sat.