Records from 2003 to 2017. Most recent: inspection, 20 June 2017.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 9 September 2015
Resolved
Provide proof of DAPI enrollment of operating crew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 November 2015
Resolution: Vessel provided proof of DAPI enrollment along with crew.
Operations/Management › Drills/Instruction › Not Conducted
Issued 9 September 2015
Resolved
Prior to operation conduct underway drills with licensed crew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 November 2015
Resolution: Vessel completed satisfactory drills.
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 May 2014
Resolved
Prove proper operation of high bilge alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 January 2015
Lifesaving › Lifebuoys › Serviceable
Issued 29 May 2014
Resolved
Provide new life ring and lanyard for water light.
Action required: 705 - Other - as specified
Due 10 June 2014
Resolved 22 January 2015
Electrical › Lighting (service) › Conductor
Issued 29 May 2014
Resolved
Replace twist on wire nuts on Navigation light wires with acceptable connections.
Action required: 705 - Other - as specified
Due 10 June 2014
Resolved 22 January 2015
Communications › Radio Communications › VHF Radiotelephone
Issued 29 May 2014
Resolved
Replace or remove inoperative VHF Radio. Providing proper ship to shore communications.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 January 2015
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 29 May 2014
Resolved
Provide Marine Radio Operators Permit for vessel operator.
Action required: 705 - Other - as specified
Due 10 June 2014
Resolved 22 January 2015
Electrical › Electric Supply System (service) › Battery Conductor
Issued 19 May 2008
Resolved
Provide permanent connections on battery terminals. 46 CFR 183.350
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 May 2008
Resolved 30 May 2008
Resolution: Permanent type connections installed on battery terminals.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 11 June 2007
Resolved
Provide Fixed Fire Extinguisher Servicing Certificate prior to operating.
Action required: 705 - Other - as specified
Due 14 June 2007
Resolved 14 June 2007
Resolution: Seviced fixed fire extinguishing system on 13 June 07.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 11 June 2007
Resolved
Secure portable fire extinguisher with approved bracket.
Action required: 705 - Other - as specified
Due 30 June 2007
Resolved 14 June 2007
Resolution: Removed extra portable fire extinguisher from vessel. Still have 02 B-II extinguishers on vessel, plus fixed system for engine compartment.
Lifesaving › Hand Flares › Quantity
Issued 11 June 2007
Resolved
Provide 02 orange day smoke flares.
Action required: 705 - Other - as specified
Due 30 June 2007
Resolved 18 June 2007
Resolution: Provided 02 orange day smoke flares.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 11 June 2007
Resolved
Provide separate stowage for adult and child life preservers and label each.
Action required: 705 - Other - as specified
Due 30 June 2007
Resolved 18 June 2007
Resolution: Provided separate stowage for adult and child life preservers and labeled each accordingly.
Communications › Visual Communication › Signalling Lamp
Issued 11 June 2007
Resolved
Provide portable light.
Action required: 705 - Other - as specified
Due 30 June 2007
Resolved 14 June 2007
Resolution: Added working flashlight to vessel.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 30 May 2006
Resolved
Service fixed fire extinguisher in engine space
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2006
Resolved 1 June 2006
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 30 May 2006
Resolved
Secure portable fire extinguisher with working bracket.
Action required: 705 - Other - as specified
Due 15 June 2006
Resolved 15 June 2006
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 30 May 2006
Resolved
Provide working float switch for electronic bilge.
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2006
Resolved 1 June 2006
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 30 May 2006
Resolved
Provide portable bilge pump.
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 15 June 2006
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 30 May 2006
Resolved
Provide working horn.
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 15 June 2006
Lifesaving › Hand Flares › Expired
Issued 30 May 2006
Resolved
Provide one orange flare.
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 15 June 2006
Stability › Weathertight Integrity › General
Issued 30 May 2006
Resolved
Replace foam/rubber seal on Engine Room hatch.
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 15 June 2006
Operations/Management › Drills/Instruction › Not Conducted
Issued 30 May 2006
Resolved
Conduct emergency instruction/drills training with all current/new members and keep record on vsl.
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 15 June 2006
Documentation › Certificates/Documents › Certificate of Inspection
Issued 30 May 2006
Resolved
Provide copy of stability letter and COI on vsl in binder.
Action required: 705 - Other - as specified
Due 31 May 2006
Resolved 15 June 2006
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 17 May 2005
Resolved
Provide service report attesting to servicing of fixed firefighting system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 June 2005
Resolution: Received copy of servicing report.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 17 May 2005
Resolved
Provide EAP hotline numbers and supervisor training.
Condition: Unknown
Due 31 May 2005
Resolved 2 June 2005
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 May 2005
Resolved
Provide COI/Stability Letter on board vessel.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 June 2005
Fire Fighting › Ventilation Systems › Operating Controls
Issued 17 May 2005
Resolved
Provide means of shutting engine compartment ventilation.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2005
Resolution: Corrected on the spot.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 17 May 2005
Resolved
Stencil fuel shut-off location.
Condition: Unknown
Due 31 May 2005
Resolved 17 May 2005
Resolution: Corrected on the spot.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 May 2005
Resolved
Stencil first aid kit location.
Condition: Unknown
Due 31 May 2005
Resolved 2 June 2005
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 17 May 2005
Resolved
Provide flashlight in vicinty of operating station.
Condition: Unknown
Due 31 May 2005
Resolved 2 June 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 May 2005
Resolved
Replace plastic wire hangers with metal hangers.
Condition: Improper Installation
Due 31 May 2005
Resolved 2 June 2005
Communications › Radio Communications › VHF Radiotelephone
Issued 17 May 2005
Resolved
Provide emergency radio broadcast placard.
Condition: Unknown
Due 31 May 2005
Resolved 2 June 2005
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 17 May 2005
Resolved
Provide training log.
Due 31 May 2005
Resolved 2 June 2005
Communications › Radio Communications › VHF Radiotelephone
Issued 17 May 2005
Resolved
Prior to utilizing passenger count equivalency, provide FCC marine operator permits.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 2 June 2005
Documentation › Certificates/Documents › FCC SSL
Issued 2 June 2004
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 16 June 2004
Resolved 21 June 2004
Documentation › Certificates/Documents › FCC SSL
Issued 2 June 2004
Resolved
Provide a FCC operator's license
Due 16 June 2004
Resolved 21 June 2004
Fire Fighting › Fire Pumps › Capacity
Issued 2 June 2004
Resolved
Provide 3 fire buckets properly stenciled and with a lanyard attached
Due 16 June 2004
Resolved 21 June 2004
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 18 July 2003
Resolved
CONDUCT MAN OVERBOARD AND FIRE DRILLS IN THE PRESENCE OF A USCG MARINE INSPECTOR PRIOR TO CARRYING PASSENGERS FOR HIRE. LEGACY COMPONENT DESC: Man Overboard Recovery
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2004
Resolved 16 June 2004
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 18 July 2003
Resolved
PROVIDE PROOF OF ENROLLMENT IN A DRUG TESTING PROGRAM PRIOR TO CARRYING PASSENGERS FOR HIRE. LEGACY COMPONENT DESC: Employee Coverage
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2004
Resolved 16 June 2004
Documentation › Markings/Placards
Issued 18 July 2003
Resolved
PROVIDE COPIES OF EMERGENCY PROCEDURED (46 CFR 185.510) AND LIFE JACKET DONNING PROCEDURES (46 CFR 185.516) PRIOR TO CARRYING PASSENGERS FOR HIRE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2003
Resolved 5 September 2003
Resolution: procured placard
Lifesaving › Lifebuoys
Issued 18 July 2003
Resolved
INSTALL 3-6 FOOT LENGTH OF LINE TO THE RING BUOY FLOAT LIGHT WITH A CLIP AT THE ATTACHING END TO RING PRIOR TO CARRYING PASSENGERS FOR HIRE. LEGACY COMPONENT DESC: Self-igniting Lights
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2003
Resolved 5 September 2003
Resolution: Retaining line attached
Lifesaving › Lifebuoys
Issued 18 July 2003
Resolved
INSTALL RETRO-REFLECTIVE TAPE TO THE RING BUOY. 4 STRIPS 2" WIDE EVENLY SPACED ON BOTH SIDES PRIOR TO CARRYING PASSENGERS FOR HIRE. LEGACY COMPONENT DESC: Markings (ship name/port)
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2003
Resolved 5 September 2003
Resolution: Retro tape installed