GREEN POINT is a 2003 tank ship. The Coast Guard has recorded 17 inspections since 2003, most recently in May 2021, along with 9 deficiencies and 2 operational controls.

Records from 2003 to 2021. Most recent: inspection, 13 May 2021.

Built
2003
Last inspected
13 May 2021
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9259886 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
637840
Flag
LIBERIA
—
Maury page id
psix-637840

Inspections, by type

…with no type recorded3
Years with a record 9 calendar years (2003–2021)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it29982 - Convention (Subpart B), Gross Ton
29982 - Regulatory (Subpart C or D), Gross Ton
12861 - Convention (Subpart B), Net Ton
12861 - Regulatory (Subpart C or D), Net Ton
59325 - Displacement, Ton
49511 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

13 May 2021 Administrative Inspection
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 7196533
1 July 2020 PSC B · COC-TVE Renew
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6992432
1 July 2020 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6992855
12 July 2016 Deficiency Check
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5937420
26 May 2016 COC-TVE Renew · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5875822
9 December 2009 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3647244
18 July 2008 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3271620
18 July 2008 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3271890
5 October 2006 Deficiency Check · ISPS III Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2794040
3 November 2005 Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2527432
6 April 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2327678
10 February 2005 NPV Safety Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2290857
20 August 2004 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2165795
24 February 2004 Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2011341
27 October 2003 Security Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1937210
31 July 2003 Ballast Water Examination · Certificate of Compliance
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1859808
30 July 2003 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1861702

Deficiency record · 9

Deck/Cargo › Inert Gas System › IGS Blower
Issued 26 May 2016 Resolved
At least two blowers shall be fitted which together shall be capable of delivering to the cargo tanks at least the volume of gas required by paragraph 3. The vessel's IGS has only one operational blower and does not operate as designed. 74 SOLAS (97 Cons)II-2/62.7.1
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 July 2016
Resolution: Vessel provided a report from the classification society that states the IG Blower motor was replaced and tested to the satisfaction of the attending surveyor.
Deck/Cargo › Inert Gas System › Deck Distribution System
Issued 18 July 2008 Resolved
Oxygen content analyzer is in operable. Vessel is unable to discharge cargo in US waters. Rectify deficiency to proper operation of analyzer due to certificate issuing authority.
Condition: Unknown
Due 17 August 2008
Resolved 30 July 2008
Resolution: PSCO received class report. Inert gas plant defective oxygen sensor has been renewed with a new unit. IG plant was tested and all found in satisfactory working condition.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 18 July 2008 Resolved
Incinerator blower squirrel cage missing. Part has been ordered by ship staff. Rectify to proper installation of missing part due to certificate issuing authority.
Condition: Unknown
Due 17 August 2008
Resolved 30 July 2008
Resolution: PSCO received class report. Incinerator defective primary air blower had been replaced. Incinerator was tested and all found in satisfactory working order.
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 4 November 2005 Resolved
Small temporary repair made, while onboard, to a drain line for the deck water seal. Make proper repairs to the satisfaction of Class.
Action required: 705 - Other - as specified
Due 4 November 2005
Resolved 28 November 2005
Resolution: Repairs were inspected and approved by the Classification Society.
Documentation › Logs/Records › Oil Record Book
Issued 4 November 2005 Resolved
Oil Record Book (ORB) has had a improper entry made on 02NOV05. Entry should have been "15.1", to show oil through 15ppm. Entry corrected while onboard.
Action required: 705 - Other - as specified
Resolved 4 November 2005
Operations/Management › Vessel Safety Management › Company Verification/Review/Evaluation
Issued 4 November 2005 Resolved
Master had sent out notification on, 26MAY05, for foam to be sent out for testing, with no reply back, resulting in deficiency being issued, somewhere the communication broke down. By 04DEC05 a internal audit to be conducted to determine where the break down of communications was. Provide copy of report to Sector New York by 11DEDC05.
Action required: 705 - Other - as specified
Due 11 December 2005
Resolved 23 November 2005
Resolution: An audit was carried out by Lloyds with satisfactory results. No non-conformities or observations were raised.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 3 November 2005 Resolved
Foam concentrate test to be conducted, last sample was 27APR04, as per vessel's Safety Management System this must be conducted annually. Vessel to send out sample while in the Port of New York, and provide a copy of the results to USCG.
Action required: 705 - Other - as specified
Due 4 December 2005
Resolved 30 November 2005
Resolution: Samples were taken and verified by Unitor.
Construction/Loadline › Markings › Load Line Mark
Issued 18 August 2004 Resolved
Permanently mark loadline in accordance with vessel's loadline certificate. ILLC Reg. 8
Action required: 705 - Other - as specified
Due 20 September 2004
Resolved 10 February 2005
Resolution: Load Line was found to be marked in accordance with Load Line Certificate and in accordance with ABS requirements for the size and location of the letters indicating Tropical, Tropical Fresh, Fresh, Summer and Winter. Load Line is in compliance with ABS.
Construction/Loadline › Markings
Issued 31 July 2003 Resolved
LOAD LINE NOT MARKED ON HULL IN ACCORDANCE WITH LOAD LINE CERTIFICATE. LOAD LINE WAS NOT MARKED FROM DELIVERY FROM YARD. CLASS (ABS) TO VERIFY LOAD LINE PROPERLY MARKED NOT LATER THAN 30AUG03. LEGACY COMPONENT DESC: Load Line Mark
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 August 2003
Resolved 18 August 2003

Ownership record