MAURY USCG vessel records
← All vessels

PAC ACRUX

PAC ACRUX is a 2003 public freight. The Coast Guard has recorded 20 inspections since 2016, most recently in April 2020, along with 8 deficiencies and 7 operational controls.

Records from 2016 to 2020. Most recent: operational control imposed, 29 April 2020.

Built
2003
Last inspected
29 April 2020
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 April 2020
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9262974
637849
Flag
SINGAPORE
Maury page id
psix-637849

Documentation record

Tonnage as PSIX records it20471 - Convention (Subpart B), Gross Ton
10630 - Convention (Subpart B), Net Ton
27420 - Dead Weight, Ton
38045 - Displacement, Ton
20471 - Regulatory (Subpart C or D), Gross Ton
10630 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 20

29 April 2020 In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6945549
21 April 2020 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6939380
29 October 2019 ISPS III Exam · NPV Safety Exam · MARPOL Annex I Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6841807
23 June 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6722533
22 June 2019 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6721641
16 December 2018 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6598421
12 December 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6593875
23 August 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6508057
14 August 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6512127
19 March 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6374245
16 March 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6373359
2 March 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6364709
28 February 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6363007
20 February 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6357650
14 September 2017 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6266321
13 September 2017 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6265645
16 May 2017 ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6142320
18 July 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5944566
19 March 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5836497
17 March 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5835643

Deficiency record · 8

02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 29 April 2020 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all aspects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed 3 inch by 18 inch hole in hull on starboard side between frames 36 and 34 with damage to the frames. Vessel is restriced to Grandview Anchorage pending a repair plan for hull damage approved by the US Coast Guard
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 May 2020
Resolution: Received class report from LR addressing the defieincy.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 29 October 2019 Resolved
The condition of the ship and its equipment shall be maintained to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship. During operational testing of steering gear, PSCO noted that steering pump #2 had hydraulic fluid leaking iwo the seal between motor and pump. In addition, hydraulic fluid accumulated under both #1 and #2 steering pumps, at least 1-2 cm in depth. The fixed storage tank sight glass indicated the tank level was approximately 6 cm low. C/E states pump #2 needs to be rebuilt and requested rebuild kit 3 months prior and it was received on board prior to PSCO exam. 74 SOLAS (14) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 October 2019
Resolution: Crew rebuilt steering pump no. 2. RO tested and found satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 29 October 2019 Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. When conducting operational testing, PSCO noted no water was coming out of cooling discharge outlet as required by manufacturer's instructions. C/E stated he believes the impeller is not functioning properly creating lack of cooling water. 74 SOLAS (14) III/20.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 October 2019
Resolution: Crew installed new outboard motor. RO tested outbaord and found satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 29 October 2019 Resolved
The angular position of the rudder shall be indicated on the navigation bridge and be recognizable in the steering gear space. PSCO noted that rudder angle indicators on bridge, bridge wings, steering compartment indicators, and on the steering gear itself showed a difference of 4-5 degrees depending on location. 74 SOLAS (04) II-1/29.11
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 October 2019
Resolution: Crew adjusted rudder angle indicators to show max. deviation of 2 degrees.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 October 2019 Resolved
The condition of the ship and its equipment shall be maintained in all respects and remain fit to proceed to sea without danger to the ship. PSCO noted jacket water leaks on main engine cylinders #4 and #6 as jacket water was running down the exterior of the engine while engine was secured. 74 SOLAS (14) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 October 2019
Resolution: Condition of class isssued.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 29 October 2019 Resolved
The machinery and associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed "M/E Cylinder Oil" tank in A/C room leaking oil from piping flange beside quick closing valve. Crew applied soft patch of gasket material and hose clamp and plugged drain with rags painted to match deck. 74 SOLAS (04) II-1/26.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 October 2019
Resolution: Crew repaired leak and unplugged drain.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 29 October 2019 Resolved
Drills shall be recorded. PSCO noted discrepancies of logged drills for the months of Aug 2019 and Oct 2019 indicating previous drill write ups were used. Documentation shows fire drills as being conducted at exact same date/time in two different locations onboard and a third drill write up for the same day shows third location (24Aug19). Fire drill and rescue drill logs from 13Oct19, 24Aug19, and 14Sep2019 have different locations and start times but narrative is the same for each event. These similarities give the appearance to PSCO that documentation was written but drills were not conducted as described. 74 SOLAS (14) III/19.5
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 29 October 2019
Resolution: Witnessed satisfactory fire drill in EDG space.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 December 2018 Resolved
Each loading arm and each transfer pipe system including each metallic hose, must not leak under liquid pressure at least 1.5 times the maximum allowable working pressure. Vessel's bunker line was tested with air only. Provide documentation attesting to a satisfactory liquid test of the vessels bunker line IAW 33 CFR 156.170 prior to bunkering in the U.S.
Condition: Invalid
Action required: 703 - Prior to bunkering operations
Due 12 December 2018
Resolved 16 December 2018
Resolution: Received Documentation Clearing DEF

Ownership record