INCA is a 2003 tank ship. The Coast Guard has recorded 15 inspections since 2016, most recently in June 2022, along with 5 deficiencies and 3 operational controls.
Records from 2016 to 2022. Most recent: inspection, 25 June 2022.
This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it39085 - Convention (Subpart B), Gross Ton 19936 - Convention (Subpart B), Net Ton 68439 - Dead Weight, Metric Ton 81464 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
Inspection history · 15
25 June 2022PSC B · COC-TVE Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7484755
4 June 2021PSC B · COC-TVE Annual
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7214871
7 June 2020MARPOL Annex VI Survey · PSC B · COC-TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6970176
4 June 2020Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6967800
12 December 2019PII Safety Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6871066
21 May 2019Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6689626
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 4 June 2021Resolved
Any required high-expansion foam system shall be capable of rapidly discharging a quantity of foam forming liquid sufficient to produce a volume of foam equal to five times the largest space to be protected. PSCO observed that the expansion ratio of the high expansion foam onboard is 3.83:1 according to the most recent foam analysis report. In accordance with the low expansion foam analysis report, the low expansion foam was tested as per MSC.1/Circ. 670 which is for high expansion foam. 74SOLAS(01) II-2/9.1.1
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 June 2021
Resolution: Vessel provided statement of fact from CLASS and new Foam Analysis Certificate showing 383:1 expansion ration for high expansion foam
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 4 June 2021Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fir to proceed to sea without danger to the ship or its persons onboard. Pressure sensing device for the gas regulating valve in the cargo control room was not operational. 74SOLAS(20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2021
Resolved 29 June 2021
Resolution: Class report was provided attesting to replacement of digital indicating controller and that gas regulating valve was operating correctly.
08 - Alarms › N/A - No Subsystem › Inert gas alarm
Issued 4 June 2021Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fir to proceed to sea without danger to the ship or its persons onboard. The deck seal low water level alarm was inoperable when the IG system was operational. The deck seal low water level alarm was operational when the IG system was not running. 74SOLAS(20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 June 2021
Resolved 4 June 2021
Resolution: Chief engineer used a contact spray on the electronics for the alarm. The low level alarm functioned properly while the IG system was running after such action.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 4 June 2021Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fir to proceed to sea without danger to the ship or its persons onboard. Pressure sensing device on the #1 cargo pump was disconnected and therefore nonoperational. 74SOLAS(20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2021
Resolved 29 June 2021
Resolution: Class report was submitted attesting to presure sensing device on all 3 cargo pumps attached and in working order.
The means for securing and maintaining weathertightness shall be to the satisfaction of the administration. The arrangements shall ensure that the tightness can be maintained in any sea condition. PSCO observed cargo pump room door with deteriorated gasket around its edges preventing the door from maintaining weathertightness. ICLL(88) 16.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 June 2021
Resolved 4 June 2021
Resolution: Ship filled the gap in the gasket with a solidifying foam material.