MAURY USCG vessel records
← All vessels

WENDY II

WENDY II is a tank barge. The Coast Guard has recorded 9 inspections since 2003, most recently in July 2009, along with 7 deficiencies.

Records from 2003 to 2009. Most recent: inspection, 15 July 2009.

Built
Not recorded
Last inspected
15 July 2009
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 15 July 2009
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2003–2009)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

639535
Flag
UNITED STATES
Maury page id
psix-639535

Documentation record

Tonnage as PSIX records it95 - Simplified, Gross Ton
0 - Simplified, Net Ton
95 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 9

15 July 2009 Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3535189
18 December 2008 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3382223
29 October 2007 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3104593
24 August 2006 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2763414
28 September 2005 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2508343
20 September 2004 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2200238
19 July 2004 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2146965
22 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1973357
29 July 2003 Cargo Tank Internal · Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1860352

Deficiency record · 7

Electrical › Electrical Distribution System (service) › Wiring
Issued 29 October 2007 Resolved
Renew wiring on generator.
Due 29 November 2007
Resolved 30 October 2007
Resolution: Renewed generator wiring.
Deck/Cargo › Cargo Heating › General
Issued 29 October 2007 Resolved
Repair fuel leak on thermal fluid heater.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 October 2007
Resolution: Repaired fuel leak.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 29 October 2007 Resolved
Stencil Life jackets with vessel name.
Due 29 November 2007
Resolved 30 October 2007
Resolution: Stenciled life jackets with vessel name.
Electrical › Electrical Distribution System (service) › Cable
Issued 29 October 2007 Resolved
Label stove disconnect.
Due 29 November 2007
Resolved 30 October 2007
Resolution: Labeled stove disconnect.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 19 July 2004 Resolved
Missing approval letter.
Due 19 August 2004
Resolved 3 November 2004
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 23 February 2004 Resolved
Place original Certificate of Documentation on board the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 March 2004
Resolved 25 October 2005
Electrical › Electrical Distribution System (service)
Issued 29 July 2003 Resolved
System configuration is not MSC approved. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 23 August 2003
Resolved 9 January 2004

Ownership record