MAURY USCG vessel records Sign in
← All vessels

EBANKS TIDE

EBANKS TIDE is a 2004 offshore supply vessel. The Coast Guard has recorded 12 inspections since 2003, most recently in December 2008, along with 10 deficiencies.

Records from 2003 to 2008. Most recent: inspection, 1 December 2008.

Built
2004
Last inspected
1 December 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB4888
639577
Flag
UNITED STATES
369309000 (licence lapsed)
Maury page id
psix-639577

Inspections, by type

Years with a record 6 calendar years (2003–2008)
The 12 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it1888 - Convention (Subpart B), Gross Ton
566 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDB4888MMSI 369309000 · cancelled · compulsorily equipped · granted 1 August 2003, cancelled 13 May 2013
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 12

1 December 2008 SIP Inspection/Audit · Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3371844
27 November 2008 COI Inspection · Administrative Inspection · MTSA/ISPS Verification · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3373998
25 August 2008 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3308402
25 March 2008 SIP Inspection/Audit · Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3186960
3 April 2007 Annual Inspection · Examination of Repairs · Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2900547
30 March 2006 Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2612496
6 April 2005 Administrative Inspection · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2327904
29 March 2005 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2322587
25 August 2004 MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2175904
20 February 2004 Administrative Inspection
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2009975
29 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1971398
26 August 2003 Internal Structural Exam · MARPOL Annex I Examination · Initial Certification · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1888109

Deficiency record · 10

Lifesaving › Rescue Boat Equipment › Instructions (engine start/operation)
Issued 12 December 2008 Resolved
Prove proper repairs to the rescue boat steering gear.
Action required: 705 - Other - as specified
Due 16 December 2008
Resolved 14 December 2008
Electrical › Electric Generation Source (emergency) › Switch
Issued 9 December 2008 Resolved
Prove proper operation of emergency generator automatic load transfer.
Action required: 705 - Other - as specified
Due 23 December 2008
Resolved 17 December 2008
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 9 December 2008 Resolved
Provide instruction label's in English and language of crew for all fire fighting and safety equipment.
Action required: 705 - Other - as specified
Due 9 January 2009
Resolved 27 January 2009
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 9 December 2008 Resolved
Update new address of the company operator on the Continuous Synopsis Record (CSR).
Action required: 705 - Other - as specified
Due 9 January 2009
Resolved 3 January 2009
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 9 December 2008 Resolved
Prove proper operation of the oily water seperator.
Action required: 705 - Other - as specified
Due 23 December 2008
Resolved 17 December 2008
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 27 November 2008 Resolved
Conduct maintenance on the sewage discharge valve and prove proper operation.
Action required: 705 - Other - as specified
Due 9 January 2009
Resolved 3 January 2009
Stability › Intact Stability (when using lifting gear) › General
Issued 3 April 2007 Resolved
Provide stability booklet amendment and ABS approval letter/stamp for new stability.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2007
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 3 April 2007 Resolved
Provide complete documentation for automation test procedures annual tests.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 April 2007
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 3 April 2007 Resolved
Lab on main deck does not have proper SOLAS approval. Vsl is applying through 10-82 for approval.
Due 23 August 2007
Resolved 25 March 2008
Resolution: Received approval letter from MSC approving the portable quarters under SOLAS.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 3 April 2007 Resolved
Provide [name withheld]/ MI info about changes made after approval of plans to liquid mud and brine piping. Systems are not exact to plans, further info needed(change in pipe size/location/type/penetrations) to determine if re-submittal is neccessary.
Due 23 August 2007
Resolved 3 April 2007

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.