Records from 2011 to 2017. Most recent: inspection, 31 July 2017.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 13 March 2017
Resolved
isolate, identify and make repairs to the equip causing the electrical ground on the main switchboard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 13 March 2017
Stability › Weathertight Integrity › General
Issued 13 March 2017
Resolved
Adjust pilot house fire door to close and latch properly.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 13 March 2017
Fire Fighting › Structural - A Class Divisions › Aux Spaces (moderate fire risk)
Issued 13 March 2017
Resolved
Replace the missing A-60 insulation in the bow thruster room overhead.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 13 March 2017
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 13 March 2017
Resolved
Replace steering room escape hatch indicator.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 13 March 2017
Electrical › Lighting (service) › Lighting Fixture
Issued 13 March 2017
Resolved
Provide and install guards over glass globes above range or provide shatter proof glasses
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 13 March 2017
Electrical › Electrical Distribution System (emergency) › Ground Indicator
Issued 13 March 2017
Resolved
Provide proper operation of the emergency switchboard ground indicator.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 13 March 2017
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 1 March 2017
Resolved
adjust the following quick acting watertight doors: engine room fwd, fwd ECR, engine room escape hatch, and steering room emergency escape hatch.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 13 March 2017
Engineering › Fuel Oil Service System › Hose
Issued 1 March 2017
Resolved
Replace the following fuel hoses: fuel return on the fwd bow thruster, fuel return on the port main, fuel return on the #1 SSDG, andFuel guauge hose on #2 ssdg.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 13 March 2017
Engineering › Feedwater/Condensate Water System › Tank
Issued 1 March 2017
Resolved
Repair or replace a/c cooling tank and bow thruster engine j/w expansion tank.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 13 March 2017
Engineering › Diesel Engine (propulsion-direct drive) › Emergency shutdown
Issued 2 March 2016
Resolved
Conduct complete machinery survey utilizing the procedures outlined in the PSTPs to the satisfaction of the attending Classification Society Surveyor.
Action required: 705 - Other - as specified
Due 2 April 2016
Resolved 2 April 2016
Resolution: Received documentation from vessel/ABS to satisfy the requirements of the deficiency.
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 2 March 2016
Resolved
Provide proofs of approved periodic safety test procedures (PSTP) are onboard to the satisfaction of a Coast Gaurd Marine Inspector.
Action required: 705 - Other - as specified
Due 9 March 2016
Resolved 8 March 2016
Resolution: Received required documentation from the vessel.