Records from 2004 to 2008. Most recent: inspection, 4 November 2008.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 4 November 2008
Resolved
Replace/Repair sea valve for engine intake.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2008
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 4 November 2008
Resolved
Replace propeller.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2008
Electrical › Electric Supply System (service) › Cable
Issued 4 November 2008
Resolved
Remove corrosion from battery terminals.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2008
Documentation › Certificates/Documents › Certificate of Inspection
Issued 29 October 2008
Resolved
Vessel's HULL/ISE date expired on issued Certificate of Inspection. De-activated COI. Vessel will be required to undergo a HULL/ISE, and a Renewal of COI exam prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2008
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 26 May 2006
Resolved
Demonstrate proper operation of propulsion engine shut down solenoid upon activation of fixed gas fire fighting system in machinery space as required by 46 CFR 181.420.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2006
Resolved 26 June 2006
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 26 May 2006
Resolved
Make machinery space boundaries vapor tight as required by 46 CFR 177.405.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2006
Resolved 26 June 2006
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 26 May 2006
Resolved
Mark type 1 PFDs with vessel name as required by 46 CFR 185.604
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2006
Resolved 26 June 2006
Lifesaving › Lifebuoys › Serviceable
Issued 26 May 2006
Resolved
Provide serviceable life ring buoy marked with vessel name fitted and installed as required by 46 CFR 180.70.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2006
Resolved 26 June 2006
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 26 May 2006
Resolved
Mark hull with name of vessel as required by 46 CFR 185.602.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2006
Resolved 26 June 2006
Communications › Radio Communications › EPIRB
Issued 26 May 2006
Resolved
Mark CAT1 406 Mhz EPIRB with vessel name as required by 46 CFR 185.604.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2006
Resolved 26 June 2006
Operations/Management › Drills/Instruction › Not Conducted
Issued 26 May 2006
Resolved
Conduct emergency steering drill using auxiliary steering arrangements as required by 46 CFR 176.500.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2006
Resolved 26 June 2006
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 4 May 2006
Resolved
Provide proof of valid Certificate of Documentation as required by 46 CFR 67.7.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2006
Resolved 26 May 2006
Construction/Loadline › Hull › Side Shell
Issued 4 May 2006
Resolved
Found stern mounted swim platform brackets fractured. Repair as originally fitted (46 CFR 176.800)
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 June 2006
Resolved 26 May 2006
Construction/Loadline › Hull › Side Shell
Issued 4 May 2006
Resolved
Found localized area of FRP delamination (defect) approximately 18 feet forward of transom and 2 feet below water line. Repair to as built specification. Quality and workmanship subject to the approval of the attending inspector. (46 CFR 176.800).
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2006
Resolved 26 May 2006
Stability › Watertight Integrity › General
Issued 4 May 2006
Resolved
Found forepeak watertight hatch cover gasket rotted. Replace in kind. (46 CFR 179.360).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2006
Resolved 26 May 2006
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 4 May 2006
Resolved
Found propulsion shaft strut bearing worn beyond maximum allowable wear limits. Renew bearing. (46 CFR 176.800)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2006
Resolved 26 May 2006
Construction/Loadline › Penetrations › Valve Flange
Issued 4 May 2006
Resolved
Found through hull fittings located within 6 inches of deepest load waterline not fitted with positive closure devices (hand stop valves) as required by 46 CFR 179.350 (c) and (d). Install required valves and demonstrate proper operation to the satisfaction of the attending inspector.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2006
Resolved 26 May 2006
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 4 May 2006
Resolved
Locate B-1 portable fire extinguisher at operating station as required by 46 CFR 181.500(a).
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2006
Resolved 26 June 2006
Operations/Management › Drills/Instruction › Abandon Ship
Issued 4 May 2006
Resolved
Conduct Fire, Abandon ship and man overboard training as drills as required by 46 CFR 185.520, 524.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2006
Resolved 26 June 2006
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 12 May 2005
Resolved
Replace one adult PFD, and repair retro- reflective tape on (3) children, and (2) adult PFDs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 May 2005
Resolved
Replace expired eyewash in First Aid Kit.
Action required: 705 - Other - as specified
Due 13 July 2005
Resolved 27 July 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 12 May 2005
Resolved
Provide proof of servicing both portable and fixed fire fighting systems.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2005
Engineering › Sea-water System (primary cooling) › Valve
Issued 12 May 2005
Resolved
Make proper repairs to main engine sea water valve.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2005
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 12 May 2005
Resolved
Blank off thru-hull valve for MSD system or properly install valve.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2005
Documentation › Certificates/Documents › Stability Letter
Issued 12 May 2005
Resolved
Post Stability Letter.
Action required: 705 - Other - as specified
Due 13 July 2005
Resolved 27 July 2005
Communications › Radio Communications › EPIRB
Issued 12 May 2005
Resolved
Replace hydrostatic release for EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2005
Documentation › Logs/Records › Logbook (official)
Issued 12 May 2005
Resolved
Conduct and log drills.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2005
Fire Fighting › Remote Fuel Shutoff › General
Issued 12 May 2005
Resolved
Properly mark emergency fuel shut off valves.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2005
Fire Fighting › Ventilation Systems › Ducts
Issued 12 May 2005
Resolved
Make engine room vapor tight and provide a means for closing the ventilation ducts.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 July 2005
Documentation › Certificates/Documents › FCC SSL
Issued 12 May 2005
Resolved
Provide originals for all required documents.
Action required: 705 - Other - as specified
Due 13 July 2005
Resolved 27 July 2005
Documentation › Certificates/Documents
Issued 24 March 2004
Resolved
Post Stability letter upon receipt. LEGACY COMPONENT DESC: Stability Letter
Action required: 705 - Other - as specified
Due 16 May 2004
Resolved 18 April 2004
Resolution: Stability letter posted.
Documentation › Certificates/Documents
Issued 24 March 2004
Resolved
Provide revised plan approval letter upon receipt.
Action required: 705 - Other - as specified
Due 16 May 2006
Resolved 18 April 2004
Resolution: Vessel provided plan review letter.